Skip to the record
For the highest quality transcripts.

Original source · versioned page text

Appendix C - Bushfire Hazard Assessment and Management Plan

of 69

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
PERFORMANCE OUTCOMES                         ACCEPTABLE OUTCOMES                                         PROPOSED SOLUTION
                                             Where an emergency access point is required, it
                                             complies with the relevant works codes and PSP6
                                             Engineering Design Standards.

Lot design

PO7                                          AO7                                                         PO7- No residential lots are proposed. The cottage is
Lot design and building siting minimises     Each residential lot:                                       located within the lowest hazard area and has been
bushfire hazard risk to people and           a) includes a building envelope, identified on a plan of    provided with sufficient separation to confirmed
property.                                    subdivision;                                                hazardous vegetation to secure a BAL 12.5 construction
                                                                                                         standard under AS3959.
                                             b) is of sufficient size and shape to allow for efficient
                                             emergency access to buildings for firefighting
                                             appliances (e.g. by avoiding battle-axe/hatchet lots and
                                             long narrow lots with long access driveways to
                                             buildings);
                                             c) where more than 2500m², achieves setbacks from
                                             hazardous vegetation in line with Bushfire Attack Level
                                             29 requirements as per AS3959; and
                                             d) is designed so that buildings and structures are sited
                                             in locations of lowest hazard within the lot and
                                             elements of the development least susceptible to fire
                                             are closest to the fire hazard.

Firebreaks and fire access tracks
                                                                                                         A08.2 – No specific fire breaks are proposed to be
PO8                                          AO8.1
                                                                                                         constructed. The cottage is provided with a minimum
Firebreaks and fire access tracks provide:   Where development involves the creation of a new
                                                                                                         60m dedicated APZ consisting of cleared grassed
                                             road and lots, a firebreak is provided by providing a
                                                                                                         separation to the adjoining hazardous vegetation. The
                                             cleared road reserve not less than 20 metres wide and
a) adequate access for firefighting and                                                                  APZ is located on gently sloping land and is generally
                                             maximum gradient of 12.5% around the perimeter of
other emergency vehicles; and                                                                            cleared of vegetation, hence offers suitable operating

                      JULY 2022                       BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN                                Page: 34
                                                                  296 KIDD ROAD, POMONA
Log in to download the original file

Appendix C - Bushfire Hazard Assessment and Management Plan.pdf · 8.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.