Part 9 Development codes \ 9.4 Works Codes \ 9.4.6 Sustainable Building Design
Code
Site characteristics No acceptable outcome provided Complies
PO7
Development and building siting is responsive to
Noosa Shire’s sub-tropical climate and the site’s
characteristics including topography, orientation,
existing vegetation and prevailing winds.
Building design AO8.1 The proposal meets PO8 for the following reasons –
PO8 Development provides a detailed assessment including • The building is in 4 pods allowing all dorms
Development - supporting documents, demonstrating the means by to have a minimum of 2 openings which
(a) orientates buildings and windows to make the which the design meets PO8. provide for natural ventilation and cooling
most of prevailing winds, natural ventilation and AO8.2 breezes between the buildings;
cross breezes; Development demonstrates a measured equivalent to • A balcony runs the full length of the west
(b) maximises shade to east and west walls; a 5-star Green Star rating. elevation which provide shade to the dorm
(c) contains an open and permeable built form that Editor’s note—The publications QDesign and QCompanion, walls and the neighbouring units,
connects indoor and outdoor spaces in an prepared by the State of Queensland, provide climate landscaping and proposed eaves provide
integrated design; responsive design principles for development in south east protection to the east elevation.
(d) retains existing vegetation and natural shading Queensland. Council encourages building and landscape • A pavilion style building design allows the
designers to incorporate best practice outcomes described in dorms easy accessibility to the common
where possible; these publications to help development comply with PO8.
(e) incorporates passive building design to reduce areas on site;
the need for auxiliary heating and cooling; • Some mature vegetation will be retained
(f) uses low toxic internal and external building along the frontage
materials; • Good neighbour building design has been
(g) uses natural light rather than artificial light, and balanced with orientation. The pavilion
may include skylights, atriums and light wells; design allows for passive heating and
(h) contains a minimum of two openings per cooling with the use of masonry and breeze
habitable room; block finishes which have good thermal
(i) provides a minimum floor to ceiling height of 2.7 mass properties;
metres; and • A minimum of 2 openings are proposed per
(j) enables efficient operation and use of the dorm which provide adequate natural light;
building. • A minimum of 2.7m high ceilings are
Editor's Note: Refer to Figure 9.4.6.4. provided.
Figure 9.4.6.4 - Subtropical Design
Print Date: 17/10/2025 Page 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
App G - Code Tables.pdfRelated documentApplication case desk ↗
About this file
- File size
- 918 KB (small file)
- File type
No other editions are linked here.