Council archive · source document
Environmental Noise Level Impact Assessment of Facilities Building · 132005.1133.13
Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads Page 12 of 16 Closest Residential to North The next closest residential apartments with direct line of sight to the outdoor dining area are to the north – Block 14, and to the north-north-west, Block 2. Block 14 is approximately 75 metres from the outdoor dining area and has line of sight to approximately 80% of the outdoor dining area. Block 2 is approximately 50 metres from the outdoor dining area and has line of sight to approximately 60% of the outdoor dining area. Block 14 At a 75 metre separation distance the patron noise levels would be: 0600 to 0700 hours: 85 dB(A) LWA – 46 (distance) = 39 dB(A) LAeq,adj,T with line of sight, less 7 dB(A) for the residential balcony balustrade = 32 dB(A) LAeq,adj,T. 0700 to 2200 hours: 95 dB(A) LWA – 46 (distance) = 49 dB(A) LAeq,adj,T with line of sight less 7 dB(A) for the residential balcony balustrade = 42 dB(A) LAeq,adj,T. 2200 hours to midnight: 92.5 dB(A) LWA – 46 (distance) = 46.5 dB(A) LAeq,adj,T with line of sight, less 7 dB(A) for the residential balcony balustrade = 40 dB(A) LAeq,adj,T. For the time varying noise of patrons laughing and talking the noise limits are: daytime (0700 to 1800 hours): 50 dB(A) LAeq,adj,T; evening (1800 to 2200 hours): 45 dB(A) LAeq,adj,T; night-time (2200 to 0700 hours): 40 dB(A) LAeq,adj,T. The daytime, evening and night-time noise limits are complied with for the above scenarios, for Block 14. Block 2 At a 50 metre separation distance the patron noise levels would be: 0600 to 0700 hours: 83 dB(A) LWA – 42 (distance) = 41 dB(A) LAeq,adj,T with line of sight, less 7 dB(A) for the residential balcony balustrade = 34 dB(A) LAeq,adj,T. 0700 to 2200 hours: 93 dB(A) LWA – 42 (distance) = 51 dB(A) LAeq,adj,T with line of sight less 7 dB(A) for the residential balcony balustrade = 44 dB(A) LAeq,adj,T. 2200 hours to midnight: 90.5 dB(A) LWA – 42 (distance) = 48.5 dB(A) LAeq,adj,T with line of sight, less 7 dB(A) for the residential balcony balustrade = 41 dB(A) LAeq,adj,T. For the time varying noise of patrons laughing and talking the noise limits are: daytime (0700 to 1800 hours): 50 dB(A) LAeq,adj,T; evening (1800 to 2200 hours): 45 dB(A) LAeq,adj,T; night-time (2200 to 0700 hours): 40 dB(A) LAeq,adj,T. The daytime and evening noise limits are complied with for the above scenarios, as is the early morning period. However, the night-time period (2200 to midnight) is potentially exceeded by 1 dB(A). Given that it is unlikely that there would still be 100 patrons in the outdoor dining area between 2200 hours and midnight on a regular basis, this minor exceedance should be considered acceptable. David Moore & Associates Pty Ltd Our reference: R19083/D3422/Rev.2/18.12.19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Environmental Noise Level Impact Assessment of Facilities Building.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.