Environmental Noise Level Impact Assessment of Facilities Building · 132005.1133.13
Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads Page 14 of 16 night-time (0600 to 0700 hours and 2200 hours to midnight) = 88 dB(A) LWA, which is equivalent to 71 dB(A) + 5 = 76 dB(A) LAeq,adj,T at 3 metres from the speakers. In addition to the above any live performer must be required to play through the in-house system. No speakers (in addition to the in-house system) are to be permitted on site. NOISE CONTROL The noise limits adopted in this noise impact assessment report for the Facilities Building are: Steady state noise: daytime (0700 to 1900 hours): 50 dB(A) LAeq,adj,T; evening (1900 to 2200 hours): 43 dB(A) LAeq,adj,T; night-time (2200 hours to midnight): 38 dB(A) LAeq,adj,T; time varying noise: daytime (0700 to 1800 hours): 50 dB(A) LAeq,adj,T; evening (1800 to 2200 hours): 45 dB(A) LAeq,adj,T; night-time (2200 hours to midnight): 40 dB(A) LAeq,adj,T. All of the noise level impact calculations detailed in this report are to the closest residential external living areas, namely balconies or courtyards. In consideration of the potential for noise impact inside the residential apartments, this will be significantly less due the fact that all habitable rooms of all apartments are fully air-conditioned, enabling external openings to be closed and maintaining an acceptable level of temperature comfort inside the apartment. Additionally, all sliding glass doors are fitted with 6 mm thick toughened glass with an Rw 28 to 30. For Block 3 (at least), where there is also fixed panes of glass above the sliding glass doors to access the balconies, these have 6 mm float glass with a similar Rw to the sliding glass doors. In accordance with the Council approval, the following noise control measure requirements should be noted: 82. The development shall comply with the noise management strategies contained in the report prepared by Ron Rumble Pty Ltd and dated November 2006, with the following additional details to be provided prior to issue of Operational Works to the reasonable satisfaction of Manager, Environmental Health Noosa Council: - 83.1 The necessary and appropriate noise control measures incorporated into the façade of the apartments and within the restaurant. These measures shall include: 83.1.1 Upgraded glazing and air-conditioning to the potentially affected apartments; 83.1.2 Strategically placed wing walls on balconies to screen the apartment and balconies from alfresco dining areas; 83.1.3 Installation of a roof over the outdoor dining area with absorption to the underside should be explored; 83.1.4 Revised hours of operation to no later than midnight; 83.2 Formulate and implement a Noise Management Plan to deal with noise emissions from the premises including patron noise. 83.3 The applicant must advise prospective purchasers that a noise management plan has been prepared to manage noise emissions related to the development. 83.4 The Noise Management Plan referred to in Condition 83.2 shall be incorporated in perpetuity in the By-Laws of the Body Corp for the building. David Moore & Associates Pty Ltd Our reference: R19083/D3422/Rev.2/18.12.19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Environmental Noise Level Impact Assessment of Facilities Building.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.