Environmental Noise Level Impact Assessment of Facilities Building · 132005.1133.13
Altum Constructions Environmental Noise Level Impact Assessment of Facilities Building, Parkridge, 75 Resort Drive, Noosa Heads Page 16 of 16 6. Any live performer must be required to play through the in-house system. No speakers (in addition to the in-house system) are to be permitted on site. 7. Plant and equipment (excluding the kitchen exhaust) can operate 24-hours per day, 7-days per week. 8. Kitchen exhaust fan can be operated on ‘high’ (75%) from 0600 to 2200 hours. From 2200 hours to midnight the kitchen exhaust fan must only be operated on ‘low’ (50%), or turned off. 9. Access door into the rooftop plant deck (western side of plant deck) must be kept closed at all times. It is a requirement of Condition 82 (and to a lesser extent Condition 84) that a noise assessment of the plant and equipment be conducted to confirm compliance with the noise limits. This plant and equipment noise assessment was conducted on Monday 2 and Wednesday 18 December 2019. With the kitchen exhaust fan operating on ‘high’ from 0600 to 2200 hours and then, from 2200 hours to midnight, operating at ‘low’ (50%), together with all other plant and equipment operating 24-hours per day, all of the steady state noise limits are complied with. CONCLUSIONS The Facilities Building of Parkridge is located at 75 Resort Drive, Noosa Heads. The proposed hours of operation for this Facilities Building are 0600 hours to midnight, daily. Potential noise impacts from the Facilities Building include: 1. delivery vehicles; 2. waste collection vehicles; 3. plant and equipment; 4. patron noise; 5. amplified music. The closest residential to the Facilities Building are: Block 3 to the west; Block 2 to the north-north-west; Block 14 to the north; Blocks 18, 19, 20 and 21 to the east. Noise limits have been established for the Facilities Building with due consideration of the following: Acoustic Quality Objectives, Environmental Protection (Noise) Policy 2008; ‘background creep’ criteria of the Environmental Protection (Noise) Policy 2008; plant and equipment noise limits contained in Noosa Council Decision Notice for Application number 132005.12133.9 dated 14 May 2019, specifically Condition 81; Australian Standard AS 2107:2000, Acoustics – Recommended design sound levels and reverberation times for building interiors. From the calculations detailed in this report noise control measures have been defined. All of these noise control measures, as detailed in the Noise Control section of this report, are in place. The Facilities Building can operate in accordance with the Noise Management Plan from 0600 hours to midnight, daily, and comply with all of the noise limit requirements of Noosa Council. David Moore & Associates Pty Ltd Our reference: R19083/D3422/Rev.2/18.12.19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Environmental Noise Level Impact Assessment of Facilities Building.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.