GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
NOOSA COUNCIL THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
APPROVED PLAN 9
8
MCU RFI RESPONSE
CONSULTANT ISSUE
22.09.25
02.05.25
7 CONSULTANT ISSUE 30.04.25
MCU25/0053 & OPW25/0074 6 MINOR UPDATES 24.04.25
5 STRUCT UPDATES 09.04.25
21 NOVEMBER 2025 4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
1 2 2 1
40.03 REV DESCRIPTION DATE
40.03 40.02 40.02
1 2 3 4 5 6 7 REVISION SCHEDULE
LEGEND
CODE DESCRIPTION
AFG-SD1 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 4-PANEL XXXO
AFG-SD2 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 3-PANEL XXO
BAL-02 BALUSTRADE TYPE 2
BAL-03 BALUSTRADE TYPE 3
BLK-200 190mm CORE-FILLED BLOCKWORK
7292 3380 8500 7160 11435 6000 4690 7000 CNC-PF CONCRETE - PAINT FINISH
COL-A CONCRE COLUMN - PAINT FINISH
COL-B STEEL COLUMN
TFD-01 TIMBER DECKING
VB VANITY BASIN
26945 WC TOILET SUITE
2000 SIDE BOUNDARY FENCE
HT
754
2005
RL 2.650 +
R9
POOL
2005
RL 0.800 +
740 5050
A BAL-02 A
DOOR LEGEND
890
BBQ SK BAR PLANTER
ENTRY HT COL-A COL-A
550 2425
LEVEL OR UNIT NUMBER
***
PAVING D**
3000
3000
DOOR NUMBER
RL 2.300 GATE HOSE TAP HT BAL-02
200
MAXIMUM RL 2.100 + GATE BAL-03
SLOPE 1:15 WINDOW/GLAZING LEGEND
9
W** L**
564
COL-A COL-A
GATE LIVING
R2
WINDOW NUMBER LEVEL NUMBER
FT-01
COL-B
2 FFL 2.725 WALL TYPES
AFG-SD2
AFG-SD2
40.01 RL 2.725
PARTITION STUD WALL WITH LININGS AS NOTED,
11210
SEWER LINE
BAL-02 REFER ARCH. SCHEDULES
7000
CONCRETE/PRECAST WALL/PANEL. FINISHES AS
POOL TERRACE
FRONT COURT NOTED, REFER ARCH. SCHEDULE
BLK-200
COL-A EX-FT-01 TFD-01 RL 1.300
LANDSCAPING
COL-B FFL 2.650 CONCRETE/PRECAST WALLPANEL WITH LINING.
FINISHES AS NOTED, REFER TO ARCH. SCHEDULE
FFL 2.725
DINING
KEY TMF-01 CONCRETE BLOCK WALL WITH LINING.
1800 FRONT BOUNDARY
2024
DROP BLK-200 COL-B BAL-03 FINISHES AS NOTED, REFER ARCH. SCHEDULE
FENCE AND GATE FFL 2.700
COL-B REAR TERRACE CONCRETE BLOCK WALL. FINISHES AS NOTED, REFER
EX-FT-01 ARCH. SCHEDULE
200
HT SHR COL-B
1000
FFL 2.700 ALUMINIUM FRAMED GLAZING SUITE. REFER TO
SHR 1000 COL-B SK
WC ELEVATIONS AND DETAILS.
HALL
WT-20
ROBE
ROBE
KITCHEN
2500
TMF-01
RL 2.700
ENS 4 ENS 5
1100
2265
WT-20
790 PLANTER SERVICE PENETRATION ZONE
BLK-200 COL-B TMF-01
B B
ROBE
FT-01 WC FT-01
60095600
VB VB
1 1
BLK-200
2 2
200
1600
GENERAL NOTES:
3
WT-20
BLK-200 4
5
3
4
LIFT CNC-PF BLK-200
6 5
SCULLERY 1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
WT-12
OUTDOOR ROOM FAMILY STAIR
965
7 6
FT-01 SYSTEMS, LININGS & FINISHES.
4400
COL-A
BLK-200
EX-FT-01 TMF-01 FT-01
8 7
BLK-200 1100 2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
1
AFG-SD1
9
DRIVEWAY BED 4 BED 5
8
BAL-03 GATE
3500
3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
60095600
10
VB WC BLK-200 SK
PDR
9
40.01 14 7 COBBLESTONE 4 CPT-01 CPT-01 10 WT-20
BLK-200
AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
FT-01 LT UPPERMOST FFL NOTED ONLY.
3645
11
12 13 14 15 16 17 18
MH 4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
BLK-200 BLK-200 LAUNDRY REINF. WALL DEFLECTION AND STRUCTURAL MOVEMENT.
965
PLANTER
C FT-01
C 5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
100
RL 2.560
COL-B COL-B COL-B HT REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
HT WM BAL-02
280 600
RL 2.675 RL 2.675 BLK-200 BAR SK BBQ HT 6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
REQUIREMENTS.
200
2500
SIDE COURT DRY COURT
0
2500
8 7 6 5 4 3 2 1 7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
RL 2.700 + RL 1.300 + WITH AS2419 AND AS2441.
1500
1500
RL 2.675
RL 2.675 RL 2.675 8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
HT CONSTRUCTION.
2000 SIDE BOUNDARY FENCE 9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
200 3995 200 3995 200 2010 200 2770 2890 200 3795 3540 200 1100 200 1400 200 1100 125 2712 200 1938 125 1100 200 3190 10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
INFORMATION.
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
STRUCTURAL ENGINEERS DETAILS
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.