                                                                                                                                                                                                                                                                                                          GENERAL NOTES
                                                                                                                                                                                                                                                                                                          VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.

                                                                                                                                                                                                                                                                                                          COPYRIGHT
                                                                                                                                                                                                                                                                                                          THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
                                                                                                                                                                                                                                                                                                          SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
                 NOOSA COUNCIL                                                                                                                                                                                                                                                                            THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
                                                                                                                                                                                                                                                                                                          LOCATION DESCRIBE HEREON


                 APPROVED PLAN                                                                                                                                                                                                                                                                             7
                                                                                                                                                                                                                                                                                                           6
                                                                                                                                                                                                                                                                                                                           MCU RFI RESPONSE
                                                                                                                                                                                                                                                                                                                           CONSULTANT ISSUE
                                                                                                                                                                                                                                                                                                                                                                                               22.09.25
                                                                                                                                                                                                                                                                                                                                                                                               02.05.25
              MCU25/0053 & OPW25/0074                                                                                                                                                                                                                                                                      5
                                                                                                                                                                                                                                                                                                           4
                                                                                                                                                                                                                                                                                                                           CONSULTANT ISSUE
                                                                                                                                                                                                                                                                                                                           UPDATED BASEMENT, STRUCTURE
                                                                                                                                                                                                                                                                                                                                                                                               30.04.25
                                                                                                                                                                                                                                                                                                                                                                                               11.03.25
                21 NOVEMBER 2025                                                                                                                                                                                                                                                                           3
                                                                                                                                                                                                                                                                                                           2
                                                                                                                                                                                                                                                                                                                           GENERAL UPDATES
                                                                                                                                                                                                                                                                                                                           CONSULTANT COORDINATION
                                                                                                                                                                                                                                                                                                                                                                                               30.01.25
                                                                                                                                                                                                                                                                                                                                                                                               16.01.25
                                                                                                                                                                                                                                                                                                           1               STRUCTURAL ENG INFORMATION                                          08.01.25
                                                                           A                                                                                B                   C                                        A                                                              B         C
                                                                                                                                                                                                                                                                                                           REV DESCRIPTION                                                                     DATE
                                                                                                                                                                                                                                                                                                           REVISION SCHEDULE

                                                                                                                                                                                                                                                                                                           LEGEND
                                                                                                                                                                                                                                                                                                           CODE                        DESCRIPTION

                                                                                                                                                                                                                                                                                                           AFG-01                      ALUMINIUM FRAMED GLAZING - TYPE 1
                                                                                                                                                                                                                                                                                                           AFG-SD1                     ALUMINIUM FRAMED GLAZED SLIDING DOOR - 4-PANEL XXXO
                                                                                                                                                                                                                                                                                                           AFG-SD2                     ALUMINIUM FRAMED GLAZED SLIDING DOOR - 3-PANEL XXO
                                                                  2005                                            11210                                                  4400             2500
                                                                                                                                                                                                                                                                                                           AFG-SD3                     ALUMINIUM FRAMED GLAZED SLIDING DOOR - 2-PANEL XO
                                                                SETBACK                                                                                                                 SETBACK
                                                                                                                                                                                                                                                                                                           BAL-01                      BALUSTRADE TYPE 1
                                                                                                                                                                                                                                                                                                           BAL-02                      BALUSTRADE TYPE 2
                                                                                                                          8M HEIGHT                                                                                                                                                                        BAL-03                      BALUSTRADE TYPE 3
                                                                                                                                                                                                                                                                                                           CNC-PF                      CONCRETE - PAINT FINISH
                                                                                                                                                                                                                                                                                                           COL-A                       CONCRE COLUMN - PAINT FINISH
                                       ROOF                                                                                                                                                                                                                                                                RND                         RENDER - PAINT FINISH
                                       RL 9.800
                                                                                                                                                                                                                                                                                                           SCN-01                      SCREEN - TYPE 1
                                                                                                                                                                                                                                                                                                           SGG                         SLIDING GLASS GATE
                                                                                                                                                                                                                                                                                                           SMG                         SLIDING METAL GATE
                                                                                                                                                                                         SCN-01                                                                                                            SST                         STACKED STONE VENEER
                                                         3450




                                       01_FIRST FLOOR
                                       RL 6.350
                                                                                                              AFG-01
                                                                                                                                                                                             1500
                                                                                                                                                                                           SETBACK
                                                                                                                                                                                                                                                                  1800 FRONT BOUNDARY
                                                         3650




                                                                                                                                                                                                                                                                  FENCE AND GATE
                                                                                                                                                                RND


                                                                                                                                                                                                                                  SGG                 SST                                   SMG
                                       00_GROUND FLOOR
                                       RL 2.700                                                                                                                                                          DFL
                                                                                                                                                                                                     RL 2.400

                                                                                                                          NATURAL GROUND LINE




                                                                                                       NORTH ELEVATION                                                                                                                      FRONT BOUNDARY ELEVATION
                                                                                               1       1 : 100
                                                                                                                                                                                                                                        3   1 : 100




                                                                                                                                                                                                                                                                                                          GENERAL NOTES:
                                                                                                                                                                                                                                                                                                          1.         REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
                                                                                                                                                                                                                                                                                                                     SYSTEMS, LININGS & FINISHES.
                                                                                                                                                                                                                                                                                                          2.         ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
                                                                                                                                                                                                                                                                                                          3.         FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
                                                                                                                                                                                                                                                                                                                     AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
                                                                                                                                                                                                                                                                                                                     UPPERMOST FFL NOTED ONLY.
                                                                                                                                                                                                                                                                                                          4.         ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
                                                                                                                                                                                                                                                                                                                     DEFLECTION AND STRUCTURAL MOVEMENT.
                                                                               C                              B                                                                     A                                        C                    B                                                   A   5.         REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
                                                                                                                                                                                                                                                                                                                     REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
                                                                                                                                                                                                                                                                                                          6.         REFER TO NCC REPORT & ESD REPORT FOR THERMAL
                                                                                                                                                                                                                                                                                                                     REQUIREMENTS.
                                                                                                                                                                                                                                                                                                          7.         FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
                                                                                                                                                                                                                                                                                                                     WITH AS2419 AND AS2441.
                                                                                                                                                                                                                                                                                                          8.         VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
                                                                                                                                                                                                                                                                                                                     CONSTRUCTION.
                                                                                                                                                                                                                                                                                                          9.         REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
                                                                                                                                                                                                                                                                                                                     SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
                                                                                                                                                                                                                                                                                                          10.        REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
                                                                                                                                                                                                                                                                                                                     INFORMATION.
                                                                                                                                                                                                                                                                                                          11.        ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
                                                                   2500                      4400                                                   11210                                  2005                                                                                                                      STRUCTURAL ENGINEERS DETAILS
                                                                 SETBACK                                                                                                                 SETBACK
                                                                                                                                                                                                                                                                                                          12.        OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
                                                                                                                                                                                                                                                                                                                     ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
                                                                                                                                                                                                                                                                                                                     BE COORDINATED WITH THE ARCHITECT.
                                                                                                                            8M HEIGHT                                                                                                                                                                     13.        REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
                                                                 CNC-PF                                                                                                                                                                                                                                   14.        ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
                                                                                                                                                                                                                                                                                                                     ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
                                       ROOF
                                                                                                                                                                                                                                                                                                                     FINISH.
                                       RL 9.800
                                                                                                                                                                                                                                                                                                          15.        DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
                                                                                   AFG-SD3           AFG-01                           AFG-SD1                                                                                                                                                                        REQUIREMENTS.
                                                                                                                                                                                                                                                                                                          16.        ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
                                                                                                                                                                                                                                                                                                                     VERIFY PRIOR TO CONSTRUCTION.
                                                                                                                                                                                           SCN-01
                                                         3450




                                                                                                                             BAL-01
                                                                 CNC-PF
                                       01_FIRST FLOOR                                                                                   SST
                                       RL 6.350

                                                                           AFG-SD1                                                        AFG-SD2

                                                                                             COL-A                                                                    COL-A
                                                         3650




                                                                                                                                                                                                                                                                                                          bureau^proberts PTY LTD
                                                                                                                                                                                                                                                                                                          ABN 53 073 087 993 ACN 073 087 993
                                                                                                                                                                                                                                                                                                          LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
                                                                                                                                                                                                                                                                                                          P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au

                                                                                                                                                                                                                                                        BAL-03                                            CLIENT:
                                       00_GROUND FLOOR
                                       RL 2.700                                                                                                                                                          DFL DFL                                            SST                                           SEYMOUR GROUP
                                                                                                                                                                                                     RL 2.400 RL 2.400                                                                                    PROJECT:

                                                                                                                                                                                                                                                                                                          NOOSA RESIDENCE
                                                                                                                                                                                                                         BAL-02

                                                                                                                            NATURAL GROUND LINE                                                                                                                                                           ADDRESS:

                                                                                                                                                                                                                                                                                                          7 NOOSA PARADE

                                                                                                                                                                                                                                                                                                          DRAWN BY:                                                                                  NORTH:
                                                                                                                                                                                                                                                                                                                                                   TH
                                                                                                                                                                                                                                                                                                          CHECK BY:
                                                                                                                                                                                                                                                                                                                                                   JC
                                                                                                                                                                                                                                                                                                          PROJECT

                                                                                                       SOUTH ELEVATION                                                                                                                      REAR BOUNDARY ELEVATION                                       ARCHITECT                                JC

                                                                                               2       1 : 100
                                                                                                                                                                                                                                        4   1 : 100
                                                                                                                                                                                                                                                                                                          DESIGN
                                                                                                                                                                                                                                                                                                          ARCHITECT                                AB
                                                                                                                                                                                                                                                                                                                                                                                                         SCALE:
                                                                                                                                                                                                                                                                                                                                                                            5             1 : 100 [A1]
                                                                                                                                                                                                                                                                                                          DRAWING TITLE:

                                                                                                                                                                                                                                                                                                          NORTH & SOUTH ELEVATIONS

                                                                                                                                                                                                                                                                                                          CAD FILE REF:                                                                                   DATE:
                                                                                                                                                                                                                                                                                                          C:\_Revit Local\24048_7 Noosa Parade_B.A_larissaf4R2ZR.rvt
                                                                                                                                                                                                                                                                                                                                                                                                 22.09.25
                                                                                                                                                                                                                                                                                                          PROJECT NO:                             PHASE:               DRAWING NUMBER:             REVISION:


                                                                                                                                                                                                                                                                                                          24048                                        B.A.            AR 30.01                             7
                                                                                                                                                                                                                                                                                                                                                                                              22/09/2025 3:37:11 PM


Document Set ID: 24343720
                  24149760
Version: 1, Version Date: 28/11/2025
                          26/09/2025

Used in these records

About this file

File size
5.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix C - Current Development Approval.pdf · 5.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.