Original source · versioned page text
SUPERSEDED - Approved Plans OPW22-0218
Plans and drawings: the text below has words only, no drawings.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
DESIGN LINE SETOUT - ACCESS DRIVEWAY NOOSA COUNCIL
POINT CHAINAGE EASTING NORTHING LEVEL BEARING RAD/SPIRAL A.LENGTH D.ANGLE APPROVED PLAN
IP 1 -4.844 3090.340 7997.750 1.680 OPW22/0218 31 OCT 2022
TC 38.156 3047.340 7997.750 2.490
IP 2 42.868 3041.340 7997.750 2.537 R = -6.000 9.425
CT 47.581 3041.340 7991.750 2.580
IP 3 80.745 3041.342 7958.586
HI CH.62.356 RL.2.675
IP CH.62.356 RL.2.675
IP CH.46.381 RL.2.572
IP CH.2.743 RL.2.136
DESIGN
SURFACE
LOT 401
LOT 402
EXISTING
SURFACE
STORMWATER
RP BOUNDARY
DRAINAGE FUTURE DRIVEWAY EXTENSION
HORIZ CURVE DATA R-6m
VERTICAL GEOMETRY GRADE 6% 1% 0.645% -0.687%
VERTICAL GRADE LENGTH 7.587m 43.638m 15.975m 18.104m
DATUM RL-1.0
CUT 0 3 0 0 0
VOLUMES
FILL 0 1 13 11 2
1.680
1.971
2.136
2.308
2.508
2.572
2.660
2.675
2.554
DESIGN CONTROL LINE
EDGE OF
1.703
2.023
2.188
2.361
2.561
2.624
2.712
CONCRETE RIGHT
EDGE OF
1.658
1.941
2.151
2.391
2.563
2.626
2.712
CONCRETE LEFT 0 0.5 1.0 1.5 2.0 2.5m
-4.844 1.680
1.974
2.202
20.000 2.273
40.000 2.310
46.381 2.578
60.000 2.429
62.356 2.419
80.000 2.532
EXISTING SURFACE
SCALE 1:50 A3
80.745
0.000
2.743
CHAINAGE 0 5.0 10 15 20 25m
SCALE 1:500 A3
PLAN DETAILS: PLAN AMENDMENTS: PLAN TITLE:
Rev Date Comment Altered Checked
Designed: AJD
Drawn: AJD A 14-04-22 ORIGINAL ISSUE AJD JP
SUNSHINE COAST OFFICE NORTH LAKES OFFICE Checked: JP B 24-08-22 ISSUE FOR APPROVAL AJD SC
Building A, Level 1, Corporate Suite A, Bld 2 Datum: AHD
6 Innovation Parkway, 2 - 4 Flinders Parade, Date: MARCH 2022
Birtinya 4575, Qld North Lakes 4509, Qld ISO 9001
MANAGEMENT This plan is Copyright. Other than for the purposes of and subject to the conditions prescribed under the Copyright Act, no part of it may in any form or by
www.ContourCE.com.au SYSTEMS
any means be reproduced, stored in a retrieval system or transmitted without the prior written permission of Contour Consulting Engineers. The plan shall not
Ph. (07) 5493 9777 Trading name of SN Registrars (Holdings) Ltd
8327 Director: BRETT THOMSON (RPEQ 6068) PLAN No: REVISION: SHEET: 10 OF 14
Document Set ID: 22090891 [email protected] Quality Assured International 3rd Party Accredited (FOR & ON BEHALF OF CONTOUR C/E PTY LTD) be used for construction without prior written approval. FILE LOCATION: C:\_PROJECTS\DD262 HAY ST, TEWANTIN\DRAWINGS\3045-010.DWG
Version: 1, Version Date: 01/09/2022
See the original