8m Max Bui
ld Height F
rom Natural Colorbond kliplok roof sheeting
20-003
Prefabricated pine roof trusses with Nom. Ground
fixed to manufacturers specification
410 Heel Height at 900 crs. Roof Bracing to for required wind category.
8m Max Build Height From Existing Ground
09
truss manufacturers specification.
1.5° Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
Heel Height
specification.
410
Q.B.C.C Lisence No.
Selected EPS sunhood/feature fixed
WD REV B
to manufacturers specification.
Project Status:
Ens Wir Bed 1
Ceiling Height
(Rendered & Painted)
Joinery
126221
2800
2700
Recessed Curtain Space
to builders detail. Nom. 100 x 50 Aluminium Batten Screen
150 High x 200 Wide. @ 150 Crs. Max to manufacturers
2° 2° specification. (ABS)
Heel Height
Heel Height
216
216
Wet Area Drop Joists to
engineers detail. Floor Framing to Recessed Curtain Space to builders
Ceiling Height
engineers detail. detail. Nom. 150 High x 200 Wide.
Garage
Joinery
2820
2700
Project Issue Date :
Wall Framing to
11/03/2022
engineers specification. Guest Bed Suspended Ceiling to
Sections
Sheet Name:
Gyprock wall & manufacturers specification.
ceiling linings.
Approx. Natural
Ground Line. Rendered 200 Series Blockwork
Fence. Max. 2000 High. to
Approx. Proposed
engineers detail.
Ground Line.
No. 38 Tristania Drive, Marcus Beach
Approx. Existing
Ground Line. Reinforced footing & slab
to engineers details.
Compacted fill to
engineers detail. SECTION A - 03 / 05 200 Series Built-Up Blockwork
Walls to engineers detail.
Scale : 1 : 100
Marcus & Amanda
8m Max Bui
ld Height F
rom Natural Colorbond kilplok roof sheeting
Prefabricated pine roof trusses with Nom. Ground
fixed to manufacturers specification
210 Heel Height at 900 crs. Roof Bracing to
Project Address :
8m Max Build Height From Existing Ground for required wind category.
truss manufacturers specification.
Client Name :
Colorbond slotted gutter, fascia
Heel Height
to match roofing. Fix to manufacturers
277
specification.
Selected EPS sunhood/feature fixed
2S
Issued by
to r
to manufacturers specification.
Ceiling Height
Revision Schedule
ey
NZP
NZP
NZP
NZP
(Rendered & Painted)
3000
Vo
Joinery
2700
id
10/02/22
16/02/22
03/03/22
11/03/22
Date
100 x 50 Aluminium Batten Screen
Stairs @ 150 Crs. Max to manufacturers
2°
Number Description
18 [email protected] 2° specification. (ABS)
WD REV A
WD REV B
Prelim WD
Heel Height
Heel Height
17 treads @ 250mm
Void Ceiling
Timber Treads to match First Floor.
PCD I
216
216
1000 High Solid Balustrade
6900
Floor Behind
Ceiling Height
1
2
3
4
Suspended Ceiling to
Office
2820
manufacturers specification.
Joinery
Gyprock wall & Stairs
2400
Entry Ceiling
4 risers @ 180mm
ceiling linings. 5 treads @ 250mm
3120
Timber Treads.
Foyer Entry
Wall Framing to
Email: [email protected]
Approx. Natural
Step
720
engineers specification.
Ground Line. Rendered 200 Series Blockwork
Website: www.iconbuildingdesign.com.au
Fence. Max. 2000 High. to
Approx. Proposed
engineers detail.
Ground Line.
Approx. Existing
Ground Line. Reinforced footing & slab
to engineers details.
Compacted fill to
200 Series Built-Up Blockwork
engineers detail.
Walls to engineers detail.
SECTION B - 03 / 05
Scale : 1 : 100
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.