20-003A_Wd_Rev_B
Attached to the e-mail Operational Works Application - DA Form 1 - Engineering Plans - Architectural Plans - Owners Consent - 38 Tristania Dr Marcus Beach - Driveway.
The original of this document is very large (12.1 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
8m Max Build
Height From
Natural Groun
d
Selected EPS sunhood/feature fixed
Colorbond kliplok roof sheeting
to manufacturers specification.
fixed to manufacturers specification
(Rendered & Painted)
1.5° for required wind category.
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
Bed 1 Ceiling Height
Aluminum framed windows
Joinery
2800
2700
to manufacturers specification.
100 x 50 Aluminium Batten Screen
@ 150 Crs. Max to manufacturers
specification. (ABS)
Rendered NRG Foamboard Walls
Ceiling Height to manufacturers specification.
2820
Joinery
2400
Rendered 200 Series Blockwork
Walls to engineers detail.
Approx. Natural
Ground Line.
Approx. Proposed
Ground Line. Rendered 200 Series Blockwork
Fence. Max. 2000 High. to
Approx. Existing engineers detail.
Ground Line. SOUTH ELEVATION
Scale : 1 : 100
Selected panel lift door fixed to
manufacturers specification.
Colorbond kliplok roof sheeting
fixed to manufacturers specification
for required wind category.
Aluminum framed windows
Colorbond slotted gutter, fascia
to manufacturers specification.
to match roofing. Fix to manufacturers
specification.
Rendered NRG Foamboard Walls
to manufacturers specification. Selected EPS sunhood/feature fixed
to manufacturers specification.
(Rendered & Painted)
Rendered 200 Series Blockwork
Walls to engineers detail.
Bed 1 Ceiling Height
Joinery
2800
Ceiling Height
2700
3040
Joinery
2700
Garage Ceiling Height
2820
Joinery
Ceiling Height
2400
3000
Joinery
2700
Joinery
Joinery
1650
1650
Approx. Natural
Ground Line.
100 x 50 Aluminium Batten Screen Approx. Proposed
@ 150 Crs. Max to manufacturers Ground Line.
specification. (ABS) WEST ELEVATION Approx. Existing
Scale : 1 : 100
Existing Blockwork Retaining Wall to remain. Ground Line.
(Shown Dashed) Omitted for clarity Built up rendered 200 series
blockwork wall to engineers detail.
Revision Schedule Project Address : Sheet Name: Project Status: Project Number:
Number Description Date Issued by No. 38 Tristania Drive, Marcus Beach Elevations WD REV B 20-003
1 PCD I 10/02/22 NZP
2 Prelim WD 16/02/22 NZP Client Name : Project Issue Date : Q.B.C.C Lisence No. Sheet Number:
Email: [email protected]
Website: www.iconbuildingdesign.com.au
3 WD REV A 03/03/22 NZP Marcus & Amanda 11/03/2022 126221 07
4 WD REV B 11/03/22 NZP
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.