Revises [oascpin fn)
New 25dn Water Service 2/25mm Meters with duol Revised nverievele oeHCBines. ‘| ¥-1006
branch end meter from check volves in individual
councd moin, by N.S.C poth boxes with unit New HCB (10) |
sumbers clearly morked. S 39.76 pT
———_—=——_ = RP Boundary Line {L 38.46 Mott 9/06/2006 4:34 PM 16115—H1—H4,d6g
-————- - oor CSC —$$<$—$ a — —_——___]
ee ee eee tae Woman
om oe 20dn tim 18dn Ic Existing branch house
tr eet
ly HC ig ye connection line to be BUILDER AND PLUMBER 10
capped ond disused
POR BY ——____ CONFIRM ALL CONNECTION
—--——— DCV OTHERS 1
| POINTS FOR SERVICES TO
PROPOSED UNITS PRIOR TO
LOT 1 Units 1 & 2 | CONSTRUCTION COMMENCING
\ | le DN40 PUMPED DISCHARGE General Notes
FROM POOL, CONNECTION 1. Hydraulic services shown are diagramatic’ only. Refer to architectural
TO GULLIES IN ACCORD drawings for locations of fixtures.
POOL BY AS3500.2.2-1996 Ct. 10.9 Alt Sanitary Hydraulics and Water Reticulotion within the allotment
OTHERS
awe eeeewseee. ocv Io boundary to be in accordance with AS3500
2 2e——err
~
HC ><j 3. All work shali comply with the requirements of authorities having
HC New HCB (10) prisdiction, offer obtaining all necessary permits and approvals
IL
S! 41.00 4. The contractor is to confirm the position of ail existing services as
ae Fe a W indicated on these and associated plons prior to the commencing of
eee
i} -—- aan ne) 18dn work
20dn ote
ea eee ee eC 5. Stormwater drainage pipes to 225% shall be Class SW uPVC HEAVY
oer ee ee ene W te ae oe ee oe ef tu 18d a@RP Boundary Line 50# Rising Main {U.N.0.) pipe. Over 2256 Concrete Rubber Ring Joint (RRU) Class 3. All
a! HC 20dn oe heer er ems we F IC pipes U.N.O. to be laid at a minimum grade of 1 in 100 U.N.O. Joins ore
Existing bronch house to be constructed in accordance with the manufacturers requirements
HC connection line to be 6. Sewers 100mm diam..uPVC DWV (U.N.0.} ond loid at o minimum
><]
a DCY POR BY capped and disused grade of 1 in 60.
———— OTHERS
7. Woter supply pipework below ground is to be
PROVIDE AN APPROVED 63mm diam. or less - High Density Type 50
J yl PUMP WELL WITH REMOTE Class 12 Polyethylene
MOUNTED CONTROL PANEL
AND WARNING SIGNAL 8. All above ground and internal water supply pipework to be Type B
Copper.
LOT 1 Units 1 & 2 9. Water services are not permitted in ground slabs and all joins ond
connections shall be mode above the slab
10. Fire Hydronts ore to be installed are to be installed in accordance
POOL BY | with AS2419.1. Hose Reels are to be installed in accordance with AS2441
11. Clean-outs, Inspection openings and Closing cops situated in
OTHERS vehicular or pedestrian pavements are to be fitted with either brass or
---—___---. DCY cast-iron covers
==sece eee
J 25¢n DJ | | 12. All in-ground valves shall be in accordance in approved concrete
os path boxes
18dn 13. All waste pipes and water services penetrating slabs 1o be wrapped
aye mere mm ne some veep eeater hfe ee ees $6 SSS ara eres emmen ame Mi a in on approved flexible joint joint wrapping
|_* 20dn 14. The term ‘SERVICE’ refers to the minimum interno! pipe diameter
—— wee Ln! = —— RP Boundory Line Sewer —-- unless nofed otherwise.
check valves in individual SITE PLAN PRIOR TO CONSTRUCTION ENGNEERS, Man Hole SGE structural - civil - Geotechnical ©
New 25dn Woier Service 2/25mm Meters with duct (Scale 1: 200) (S TD REVEW CONTOUR SERVEY CONSU Tes ENGINEERS
TO BE PROMDED) ON BOTH
ALOTWENTS {N TO CONFIRM THE
branch and meter from path boxes with unit DETALS CONTAINED HERE iN.
council moin, by N.S.C numbers clearly marked ABN 40 098 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY
Call ~ Water Meter Ph (07) 5447 5544 Fax (07) 5447 2634
OCV Oual Check Value — UPVC Sewer, size grade and invert acme «=~ Stormwoter pipe, size, grade and invert
B Both HCB House Connection Branch NRV Non-Reiurn Valve 1G Test Gate level os noted levels as noted Title internal Hydraulics Arrangement
CO Clean—Out HR 36m Fire Hose Reet ORG Overflow Relief Gully V Vent — - External Poly Water Service, size as noted — Ye — Cold and Hot Water riser
DP Rainwoter Down-Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin riser locations and size.
FP Frag Flap IC Inspection Chamber Sc Stop Cock VC Vent Cowl —cw— Internal Cold Woter service G)— - Sanitary Stack number ond Vent size
FWG Floor Waste Gully 10 Inspection Opening SHR Shower WC Woter Closet
HC Hose Cock LT Laundry Tub SK Sink WM Washing Machine —HW¥— Internal Hot Water service =O — Fixture Unit loading,See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00156930.001.pdfRelated documentPublic source context ↗
07/0386 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.