Health and Safety Personnel health and safety
Access to a Jellyfish® unit requires removing heavy Whilst performing maintenance on the VortCapture,
access covers/grates, and entry into a confined space. precautions should be taken in order to minimise
Pollutants collected by the Jellyfish® will vary depending (or when possible prevent) contact with sediment and
on the nature of your site. There is potential for these other captured pollutants by maintenance personnel.
materials to be harmful. For example, sediments may In order to achieve this the following personal protective
contain heavy metals, carcinogenic substances or equipment (PPE) is recommended:
objects such as broken glass and syringes. For these
• Puncture resistant gloves
reasons, all aspects of maintaining and cleaning your
Jellyfish® require careful adherence to Occupational • Steel capped safety boots
Health and Safety (OH&S) guidelines. • Long sleeve clothing, overalls or similar skin
It is important to note that the same level of care needs to protection
be taken to ensure the safety of non-work personnel. • Eye protection
As a result, it may be necessary to employ traffic/
pedestrian control measures when the device is situated • High visibility clothing or vest
in, or near areas with high vehicular/pedestrian activity.
During maintenance activities, it may be necessary
to implement traffic control measures. Ocean Protect
recommend that a separate site-specific traffic control
plan is implemented as required to meet the relevant
governing authority guidelines.
Whilst some aspects of Jellyfish® maintenance can be
performed from surface level, there will be a need to
enter the Jellyfish® pit (confined space) for both minor and
major services. It is recommended that all maintenance
personnel evaluate their own needs for confined space
entry and compliance with relevant industry regulations
and guidelines. Ocean Protect maintenance personnel
are fully trained and carry certification for confined space
entry applications.
4 Ocean Protect Jellyfish® Filter
90
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Judgment - Stockwell v Noosa Council - PEC Appeal 1998 of 2024 - 26.06.25.pdfRelated documentApplication case desk ↗
About this file
- File size
- 21.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.