Council archive · source document
Approved Plan - MCU25 0060 (As Published) · MCU25/0060
Plans and drawings: the text below has words only, no drawings.
Very large file (20.9 MB): may take a few minutes to open.
rnd01 tyrolian concrete textured render timber windows, doors and screens stn01 eco outdoor - Luca crazy paving to walls and floors tsh01 weathered timber cladding/battens
con01 off-form concrete con02 board-form concrete monument metal work elements stn02 travetino alabastrino bench tops tim01 tongue & groove bistre engineered timber flooring
til03 white heavensand glass mosaic pool tile con03 exposed aggregate concrete - crossover native and endemic landscaping aoysia integrated grass / landscaping
NOOSA COUNCIL
APPROVED PLAN
MCU25/0060 27 APRIL 2026
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca D 20/12/2024 SD client review 22 / 512 David Low Way, Justin + Kylie Collum look and feel SD 020.00 G SCALE 1:1
aca E 12/02/2025 SD issue for pricing Castaways Beach QLD 4567
A3
material and finishes - exterior
aca F 03/04/2025 SD client review
aca G 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 10 (of 24)
Page 2
site details
22 / 512 David Low Way,
Castaways Beach QLD 4567
Lot 22 on SP111721
Site Area 648 sqm
water line (approx. location)
vegetation
existing multistorey
rendered building
existing timber fence on
21 timber sleepers retaining
SP111721 sewer manhole
9.42
vegetation
1
m ap
existing neigbour
driveway existing vegetation outside the lot
areas
prox
existing neighbor
driveway shown shown indicative
|
indicatively ' 45"
162
58
| 252°
prox
° 50
concrete
71 m ap existing timber fence to be
3 8 .8
' 50"
demolished
vegetation
existing vegetation
sewer manhole
3 .6
85
electrical pit
m
22
ap
water meter
pro
vegetation SP111721
x
|1
47
trees required to be removed (as part of sewer IO
°
10
43
DA application) are shown in red
. 36
'1
6m
0"
ap
on-site existing trees existing chain wiring fence
pro
grass shown as per survey plan
x
|3
notes
30
°4
"
2'
20
9'
00
4
8°
"
vegetation
|5
pro
x 1. All works to be carried out in
ap accordance with the general
m
existing light pole .5 87
to be relocated 35 construction notes on coversheet
11
of this package.
.9 7
grated pit
3m
4 2. All works to be carried out in
ap
pri
pro
accordance with the DA and BA
va
x
including drawings & conditions.
|3
te
27
ex
ist
°
roa
CP
43
ing
3. Handrails are required to all
'0
d
SP111721 existing multistorey
str
0"
stairsways where a change of
ee
3
rendered building
tp
level of 575mm or greater occurs
ark
as per BCA 2013 Part 32.9.2.4.
ing
power boxes
fire hydrant
23
SP111721
telstra pit
2
1
existing neighbor
52
80
driveway shown
indicatively
35
20
site & locality plan - existing NOOSA COUNCIL
1 APPROVED PLAN
1 : 250
MCU25/0060 27 APRIL 2026
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum site existing SD 100.00 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
site & locality plan - existing
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 3
site details
22 / 512 David Low Way,
Castaways Beach QLD 4567
Lot 22 on SP111721
Site Area 648 sqm
water line (approx. location)
vegetation
existing multistorey
rendered building
existing timber fence on
21 timber sleepers retaining
SP111721 sewer manhole
9.42
vegetation
1
m ap
existing neigbour
driveway existing vegetation outside the lot
areas
prox
existing neighbor
driveway shown shown indicative
|
indicatively ' 45"
162
58
| 252°
prox
° 50
concrete
71 m ap
3 8 .8
' 50"
en
scre
fixed
sewer manhole
3 .6
85
electrical pit
m
proposed multistorey 22 landscaped area
ap
water meter
pro
building SP111721
x
|1
landscaped area
field inlet to civil
47
engineering details sewer IO
°
10
43
. 36
4
'1
6m
0"
ap
proposed relocation of accessible
existing chain wiring fence
pro
planted roof area
528
street parking grass
x
|3
0
en
notes
30
s c re
°4
ed
proposed location for proposed fix "
2'
20
pedestrial access 9'
00
existing light pole 3 4
8°
"
|5
pro
x 1. All works to be carried out in
ap accordance with the general
m
87
52
.5 construction notes on coversheet
35
80
11
of this package.
.9 7
grated pit proposed
3m
35 driveway
pump well and rising 20 2. All works to be carried out in
ap
main to discharge runoff
pro
from driveway to civil accordance with the DA and BA
pri
x
including drawings & conditions.
|3
engineering details
va
27
te
° 43
3. Handrails are required to all
roa
'0
CP existing multistorey
0"
stairsways where a change of
d
SP111721 heavy duty rendered building level of 575mm or greater occurs
trench grate
as per BCA 2013 Part 32.9.2.4.
power boxes
fire hydrant
23
SP111721
telstra pit
2
ex
ist
52
ing
80
str
ee
tp
ark
1
ing
existing neighbor
52
80
driveway shown
indicatively
35
20
1 site & locality plan - proposed NOOSA COUNCIL
1 : 250 APPROVED PLAN
MCU25/0060 27 APRIL 2026
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca D 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum site SD 100.01 G SCALE As indicated
aca E 03/04/2025 SD client review Castaways Beach QLD 4567
A3
site & locality plan - proposed
aca F 21/08/2025 RFI response
aca G 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 4
ngl +8.0
ngl +8.0
ngl
ngl
9.4m setback (corner)
5.1m setback (corner)
4.5m side setback
4.5m side setback
5.1m setback (corner)
6.0m rear setback
1 site setback 3d - view 01 2 site setback 3d - view 02
ngl +8.0
ngl +8.0
9.4m setback (corner)
ngl
ngl
5.1m setback (corner)
4.5m side setback
4.5m side setback
6.0m rear setback
3 site setback 3d - view 03 4 site setback 3d - view 04
NOOSA COUNCIL
APPROVED PLAN
MCU25/0060 27 APRIL 2026
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum site SD 100.10 H SCALE 1:1
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
site setbacks
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 5
site boundary
site boundary
northern neighbours
building on lot 21
proposed fixed
screen southern neighbours building on lot 23
accessible
screen
1630
planted roof area
650
500
1500 ca.
southern neighbours southern neighbours building on lot 23
building on lot 23
northern neighbours building on lot 21
1 Section 06 - overlooking analyses
200.00 1 : 100
northern neighbours building on lot 21
NOOSA COUNCIL
APPROVED PLAN note: the bird’s-eye view images above were taken from
MCU25/0060 27 APRIL 2026 approximately 3 metres above the eye level of the accessible
planted roof area.
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca A 21/08/2025 RFI response 22 / 512 David Low Way, Justin + Kylie Collum 100.30 B SCALE As indicated
aca B 12/11/2025 RFI response 02 Castaways Beach QLD 4567
A3
overlooking analyses 01
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 6
general notes general items legend
1. all works to be carried out in accordance with the general RL 60.200 spot level window code. refer to window 20 step up code. note step line
L1 (level)
construction notes in coversheets of this package. tos = top of step w01 (window ref) elevations + door/window occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) bos = bottom of step hardware schedules high lvl high lvl - 20 mm change
and BA including drawings & conditions. RL = lvl at point (AHD typ)
J 3. handrails are required to all stairways where a change of level of
K 1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. RL xx.xxx top of wall (surface) level Ipb01 material code. refer finishes (cos) check on site
4. where boundary locations are not clear, the builder shall arrange schedule (typical). (mir) mirrored detail
950 for survey to locate the boundaries and complete an identification SSL xx.xxx structural slab level (sim) similar detail
9 survey prior to setting out the new work. dp01 component code. (part) partial detial
(refer material code for similar)
4860 L 5. contours shown are existing and do not represent finished levels.
FFL xx.xxx finished floor level
1350
door/gate code. refer to window 2700 ceiling code
L1 (level) height*
elevations + door/window Ipb01 finish** * heights are relative to assocaited
8 1
M
d01 (door/gate ref)
10.366 m approx | 330° 42' 00"
hardware schedules finished floor
400.04 4610 * refer finishes schedule
38.87
2000
1ma
ppro 4100 N
2m s
ide s x | 25
2° 5 8
NOOSA COUNCIL
etb ack - ' 4 5"
from
4.5m
-
APPROVED PLAN
7 7.5m
NGL
1 MCU25/0060 27 APRIL 2026
9.4 m front setback
4820 O
400.05
1
100.30
1 P
Q
2010
400.07
2380
920
6
dry cavity
proje
cted
line o
fb uildin
g over
multipurpose
5 multipurpose - stn01
golf wine cellar
1380
dry stn01
stn01
cavity shower
4
tv outdoor lounge
vnt
1 FFL 26.375 pwd stn01
400.01 wc
1
stn01 FFL 26.325
2800
400.03
50 "
landscaped area
11.973 m approx | 327° 43' 00"
° 5 0'
over
g
3
| 1 62
uildin
storage
1200
pool seat
fb
prox
line o
family room/
rumpus
m ap
1
cted
2 400.02
proje
stn01
9.421
pool equipment laundry FFL 26.375
and service area pool
stn01
4700
storage landscaped area
1
6m rear setback
3.685 m approx | 147° 43' 10"
400.00
dry cavity drying court
5.1 m front setback
2m side setback - from 4.5m - 7.5 NGL
1 projected line of building over
landscaped area
35.587 m approx | 58° 49' 20"
1
400.06
1900 3950 3500 1100 4000 4700 1700 1500
A B C D E F G H I
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum floor plans SD 200.00 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
lower ground floor plan
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 7
general notes general items legend
1. all works to be carried out in accordance with the general RL 60.200 spot level window code. refer to window 20 step up code. note step line
L1 (level)
construction notes in coversheets of this package. tos = top of step w01 (window ref) elevations + door/window occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) bos = bottom of step hardware schedules high lvl high lvl - 20 mm change
and BA including drawings & conditions. RL = lvl at point (AHD typ)
J 3. handrails are required to all stairways where a change of level of
K 1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. RL xx.xxx top of wall (surface) level Ipb01 material code. refer finishes (cos) check on site
4. where boundary locations are not clear, the builder shall arrange schedule (typical). (mir) mirrored detail
950 for survey to locate the boundaries and complete an identification SSL xx.xxx structural slab level (sim) similar detail
9 survey prior to setting out the new work. dp01 component code. (part) partial detial
(refer material code for similar)
4860 L 5. contours shown are existing and do not represent finished levels.
FFL xx.xxx finished floor level
1350
door/gate code. refer to window 2700 ceiling code
L1 (level) height*
elevations + door/window Ipb01 finish** * heights are relative to assocaited
8 1
M
d01 (door/gate ref)
hardware schedules finished floor
400.04 4610 * refer finishes schedule
10.366 m approx | 330° 42' 00"
38.87
2000
1ma
pprox 4100 N
2m s
ide s | 25 2° 58
NOOSA COUNCIL
etb ack - ' 45 "
from
4.5m
-
APPROVED PLAN
7 7.5m
NGL
1 MCU25/0060 27 APRIL 2026
9.4 m front setback
4820 O
400.05
1
100.30
1 P
Q
2010
400.07
2380
920
6 guest room
robe stn01 seat snk
bbq
shw
day
guest ensuite bed fire
outdoor dining place
over
stn01 tv
wc stn01
g
uildin
vnt
mail box and
fb
house number
over
seat
line o
5
wning
cted
1380
entry
fa
proje
seat
line o
stn01
seat living
cted
4 FFL 30.050
tim01
proje
de
1
tra
400.01 1
balus
outdoor living skylight over
2800
drop off 400.03
' 50"
stn01
2° 50
pump well and rising main to FFL 30.050 FFL 29.875 landscaped area
| 16
discharge runoff from driveway to
civil engineering details
prox
3
m ap
1200
dining
9.421
heavy duty trench grate
over
tim01
11.973 m approx | 327° 43' 00"
2 1
g
uildin
400.02
corridor
driveway double car
fb
tim01
line o
con03 garage FFL 29.875
cted
storage buffet
proje
skylight over
kitchen
storage tim01
4700
snk
storage FFL 29.875
landscaped area
pantry
1
6m rear setback
tim01
400.00
awning
3.685 m approx | 147° 43' 10"
storage storage fridges ctp ovens
5.1 m front setback
2m side setback - from 4.5m - 7.5 NGL
1
landscaped area
2050
bin storage
35.587 m approx | 58° 49' 20"
1
400.06
1900 3950 3500 1100 4000 4700 1700 1500
A B C D E F G H I
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum floor plans SD 200.01 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
ground floor plan
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 8
general notes general items legend
1. all works to be carried out in accordance with the general RL 60.200 spot level window code. refer to window 20 step up code. note step line
L1 (level)
construction notes in coversheets of this package. tos = top of step w01 (window ref) elevations + door/window occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) bos = bottom of step hardware schedules high lvl high lvl - 20 mm change
and BA including drawings & conditions. RL = lvl at point (AHD typ)
J 3. handrails are required to all stairways where a change of level of
K 1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. RL xx.xxx top of wall (surface) level Ipb01 material code. refer finishes (cos) check on site
4. where boundary locations are not clear, the builder shall arrange schedule (typical). (mir) mirrored detail
950 for survey to locate the boundaries and complete an identification SSL xx.xxx structural slab level (sim) similar detail
9 survey prior to setting out the new work. dp01 component code. (part) partial detial
(refer material code for similar)
4860 L 5. contours shown are existing and do not represent finished levels.
FFL xx.xxx finished floor level
1350
door/gate code. refer to window 2700 ceiling code
L1 (level) height*
elevations + door/window Ipb01 finish** * heights are relative to assocaited
8 1
M
d01 (door/gate ref)
hardware schedules finished floor
400.04 4610 * refer finishes schedule
landscaped area
2000
38.87
1ma 4100 N
10.366 m approx | 330° 42' 00"
2m s pprox
ide s
etb ack -
| 25 2° 58
' 45 "
NOOSA COUNCIL
from
4.5m
- APPROVED PLAN
7 7.5m
NGL
1
9.4 m front setback
shw
400.05 1 4820 O MCU25/0060 27 APRIL 2026
100.30
seat 1 P
Q
2010
400.07
2380
master ensuite 920
6 stn01 vnt wir her
scree
n - de
tim01 tail tb
c
vnt
robe
wc
robe
over
wc wir him master bedroom
wning
seat tim01
robe tim01
fa
FFL 33.200
line o
5
cted
1380
proje
outoor area below
4
bedroom 02
skylight
1 tim01 corridor
400.01
robe
1
tim01
2800
400.03
FFL 33.200
' 50"
2° 50
desk
| 16
3 seat
prox
shw vnt
1200
wc
11.973 m approx | 327° 43' 00"
m ap
projected line of awning over
bathroom 1
9.421
2 vnt
400.02
stn01
accessible
seat
planted roof area
stn01
FFL 33.200 FFL 33.200
skylight
bedroom 01
4700
tim01
robe
FFL 33.200 skylight
over
1
6m rear setback
400.00
3.685 m approx | 147° 43' 10"
suspended planter
desk
5.1 m front setback
2m side setback - from 4.5m - 7.5 NGL
1
landscaped area
35.587 m approx | 58° 49' 20"
1
400.06
1900 3950 3500 1100 4000 4700 1700 1500
A B C D E F G H I
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum floor plans SD 200.02 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
first floor plan
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 9
general notes general items legend
1. all works to be carried out in accordance with the general RL 60.200 spot level window code. refer to window 20 step up code. note step line
L1 (level)
existing multistorey construction notes in coversheets of this package. tos = top of step w01 (window ref) elevations + door/window occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) bos = bottom of step hardware schedules change
rendered building RL = lvl at point (AHD typ)
high lvl high lvl - 20 mm
and BA including drawings & conditions.
J 3. handrails are required to all stairways where a change of level of
K 1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. RL xx.xxx top of wall (surface) level Ipb01 material code. refer finishes (cos) check on site
4. where boundary locations are not clear, the builder shall arrange schedule (typical). (mir) mirrored detail
950 for survey to locate the boundaries and complete an identification SSL xx.xxx structural slab level (sim) similar detail
9 survey prior to setting out the new work. dp01 component code. (part) partial detial
(refer material code for similar)
4860 L 5. contours shown are existing and do not represent finished levels.
FFL xx.xxx finished floor level
1350
door/gate code. refer to window 2700 ceiling code
L1 (level) height*
elevations + door/window Ipb01 finish** * heights are relative to assocaited
8 1 d01 (door/gate ref)
400.04 4610 M hardware schedules finished floor
* refer finishes schedule
10.366 m approx | 330° 42' 00"
2000
38.87
1ma
pprox 4100 N
2m s
ide s
etb ack -
| 25 2° 58 NOOSA COUNCIL
from ' 45 "
4.5m
- APPROVED PLAN
7 7.5m
NGL
1 MCU25/0060 27 APRIL 2026
9.4 m front setback
400.05 1 4820 O
100.30
1 P
Q
2010
400.07
2380
920
6 skylight
awning
bo
xg
ut
te
r
5
1380
4
1 awning
400.01 1
2800
' 50"
400.03
2° 50
| 16
flat roof
prox
3
m ap
1200
9.421
2 1
400.02
11.973 m approx | 327° 43' 00"
accessible planted roof area
4700
skylight
1
6m rear setback
400.00
3.685 m approx | 147° 43' 10"
awning
5.1 m front setback
2m side setback - from 4.5m - 7.5 NGL
1
35.587 m approx | 58° 49' 20"
1
400.06
1900 3950 3500 1100 4000 4700 1700 1500
A B C D E F G H I
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum floor plans SD 210.00 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
roof plan
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Page 10
9 8 7 6
1350 2000 2010
1 1
site boundary
site boundary
400.03 400.02
con01 gls01 NGL + 8.0m
first floor ceiling
RL35.900
con02
2700
first floor level
con01 RL33.200
stn01 tbs01
tsh01
3325
NGL + 2.0m
con01
ground level
RL29.875
3500
lower ground level
RL26.375
1 western elevation NOOSA COUNCIL
1 : 100 APPROVED PLAN
MCU25/0060 27 APRIL 2026
general notes general items legend
RL 60.200 spot level L1 (level) window code. refer to window component code. 20 step up code. note step line
1. all works to be carried out in accordance with the general construction 6. levels and services locations for civil works may vary from those shown -
notes in coversheets of this package. verify all levels and services locations prior to commencement of tos = top of step w01 (window ref) elevations + door/window dp01 (refer material code for similar) occurs on low side of level
2. all works to be carried out in accordance with the DA (if required) and BA construction. bos = bottom of step hardware schedules low lvl low lvl + 20 mm change
including drawings & conditions. 7. concrete profile and blockwork setout is provided on 220 (series) of RL = lvl at point (AHD typ)
3. handrails are required to all stairways where a change of level of drawings, refer to these for setout. licensed surveyor to establish grids.
RL xx.xxx top of wall (surface) level door/gate code. refer to window ceiling code hose cock. refer serivces
1000mm or greater occurs as per BCA 2013 Part 3.9.2.4. where discrepancies occur the 220 series drawings are to take L1 (level)
d01 elevations + door/window 2700 * heights are relative to assocaited schedule. client to confirm
4. where boundary locations are not clear, the builder shall arrange for precedent. (door/gate ref) height* hc
hardware schedules Ipb01 finish** finished floor locations
survey to locate the boundaries and complete an identification survey
* refer finishes schedule
prior to setting out the new work. SSL xx.xxx structural slab level
5. contours shown are existing and do not represent finished levels.
material code. refer finishes J0.1 joinery code. refer to cabinetry (cos) check on site
Ipb01 Ipb01 schedule (typical). elevations on 820 (series) and (mir) mirrored detail
FFL xx.xxx finished floor level (refer also to sanitary/ applicances/
level joinery
details on 830 (series) drawings (sim) similar detail
reference
lighting/services as appropriate) (part) partial detial
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0448
aca E 12/02/2025 SD issue for pricing 22 / 512 David Low Way, Justin + Kylie Collum elevations SD 300.00 H SCALE As indicated
aca F 03/04/2025 SD client review Castaways Beach QLD 4567
A3
elevations
aca G 21/08/2025 RFI response
aca H 12/11/2025 RFI response 02
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
The text continues on page 11.
Used in these records
Approved Plan - MCU25 0060 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 20.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.