Original source · versioned page text
2020-06-15 General Committee Meeting Notes
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
RECOMMENDATIONS ONLY – NOT THE FINAL DECISION OF COUNCIL
GENERAL COMMITTEE MEETING RECOMMENDATIONS 15 JUNE 2020
b. For the Resort Facilities Building component:
i. A minimum of 30 uncovered spaces are to be designated through the
Principal Community Management Scheme as Exclusive Use Areas,
within the common property, for the Resort Facilities Building. These
parking spaces are to be accessible at all times for patrons and staff
of the Resort Facilities Building.
ii. All 30 patron and staff carparking spaces are to be provided within
proximity of the Resort Facilities Building, that is, not located along
the proposed new road along the eastern property boundary.
iii. All 30 spaces are to be fully constructed and available for use prior
to the commencement of the use of the Resort Facilities Building.
Condition 83
83. The development shall comply with the Noise Management Plan (Report No:
R19084/D3295/Rev.4/30.03.20) prepared by David Moore & Associates and
dated 30 March 2020 to the reasonable satisfaction of Council, including:
a. The necessary and appropriate noise control measures incorporated into
the façade of the apartments and within the restaurant/café in the Resort
Facilities Building. These measures shall include:
i. Upgraded glazing and air-conditioning to the potentially affected
apartments;
ii. Strategically placed wing walls on balconies to screen the apartment
and balconies from outdoor dining areas;
iii. Revised hours of operation to no later than midnight for the
restaurant/café (indoor area only);
iv. The outdoor dining areas associated with the restaurant/café use is
to operate between the hours of 6am and 10pm only;
v. After 10pm, all patrons must be within the building confines with
doors/windows closed, except for the ingress and egress of patrons
and staff;
vi. The underside of all roof elements over outdoor dining areas
associated with the café use are to be lined with acoustic absorptive
lining minimum NRC 0.7;
vii. Outdoor dining is confined to the 185m2 roofed area shown on the
approved plans.
viii. All amplified noise at the premises must be conducted through a
sound limiting device at all times to ensure that noise does not
exceed the following:
1. during the daytime and evening (0600 to 2200) must not exceed
92 dB(A) LWA, which is equivalent to 75 dB(A) + 5 = 80 dB(A)
LAeq, adj, T at 3 metres from the speakers.
ix. Any live performer must be required to play through the in-house
system. No speakers (in addition to the in-house system) are
permitted on site.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.