Appendix B - Acoustic Report
Attached to the e-mail PM Submission - Wayne Simmiss - 51995.1611.04.
Your Mates Bowlsy Pty Ltd Reference: #1859d1-B
Your Mates Bowls Pub Date: 6 March 2025
Noise Impact Assessment
2.4 Noise Monitoring
To quantify the existing acoustic environment, unattended noise monitoring was conducted from
the 21st to 30th of January 2025 using a Rion NL-42 precision noise logger. Details of the logger
are provided in Table 3.
Noise measurements were conducted in accordance with AS 1055:2018 Acoustics – Description
and measurement of environmental noise.
The noise logger was calibrated with a sound pressure level of 94.0 dB at 1 kHz before and after
the measurements. Calibration drift was within ±0.5 dB and is therefore considered acceptable.
Table 3. Equipment details
Description Serial No. NATA calibration date
Rion NL-42 Sound Level Meter 00171580 15/07/2024
Norsonic Nor139 Sound Level Meter 1393046 09/10/2023
Larson Davis CAL200 Field Calibrator 22787 10/07/2024
The noise logger was set to record statistical sound pressure levels Lmin, L90, Leq, L10, Lmax
noise descriptors over sampling periods of 15-minutes for the entire monitoring period.
The microphone was positioned 1 m from two reflecting planes (the courtyard fence and storage
container) at a height of 1.5 m. The noise monitoring location is indicated over aerial imagery
below.