Appendix B - Acoustic Report

Attached to the e-mail PM Submission - Wayne Simmiss - 51995.1611.04.

of 35

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Your Mates Bowlsy Pty Ltd                                                                          Reference: #1859d1-B
Your Mates Bowls Pub                                                                                 Date: 6 March 2025
Noise Impact Assessment


3.4 Summary of Noise Goals
A summary of the adopted limiting criteria for this assessment has been presented in Table 7.

                                                Table 7. Adopted limiting criteria
                                                                                             Noise limit, dB
        Compliance location                Noise source         Noise descriptor
                                                                                     Day        Evening        Night
                                                                  LAeq,adj,1hr       50            50           --
      Residence (for outdoors)           All noise sources        LA10,adj,1hr       55            55           --
                                                                  LA1,adj,1hr        65            65           --

                                                                  LAeq,adj,1hr       35            35           30
      Within nearest habitable
       room (assuming open               All noise sources        LA10,adj,1hr       40            40           35
             windows)
                                                                  LA1,adj,1hr        45            45           40
       Commercial and retail
                                         All noise sources        LAeq,adj,1hr       45[1]         --           --
        activity (for indoors)
  Hospital, surgery or other
   medical institution (for              All noise sources        LAeq,adj,1hr       35[1]         --           --
           indoors)
[1]
      Only applicable when the activity is open for business.



Where indoor noise limits are specified, an attenuation of 7 dB through open windows is assumed
to assess levels on the building’s external façade.




Live It Acoustics                                                                                               Page 11
Log in to download the original file

Appendix B - Acoustic Report.pdf · 4.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.