Appendix B - Acoustic Report
Attached to the e-mail PM Submission - Wayne Simmiss - 51995.1611.04.
Your Mates Bowlsy Pty Ltd Reference: #1859d1-B
Your Mates Bowls Pub Date: 6 March 2025
Noise Impact Assessment
Appendix A – Nomenclature
Term Description
means the part of the environment of an area or place characterised by the total amount of noise
Acoustic environment
that may be experienced there.
for an area or place, means the maximum level of noise that should be experienced in the acoustic
Acoustic quality objective
environment of the area or place.
Total encompassing sound in each situation at a given time usually composed of sound from many
Ambient (or total) noise
sources near and far.
Assessment Background Level (ABL) is a single figure background level for each assessment
Assessment background
period (day, evening and night). It is the tenth percentile of the measured L90 statistical noise
level (ABL)
levels.
The following time periods are prescribed in the EHP’s Noise Measurement Manual to be used for
Assessment periods long term background noise measurements: 7am to 6pm (‘Day’); 6pm to 10pm (‘Evening’); and
10pm to 7am (‘Night’).
Background creep occurs when noise levels creep higher and higher over time with the
Background creep
establishment of new development in or near an area.
The A-weighted sound pressure level of the residual noise (dB) exceeded for 90 per cent of a given
Background noise level,
time interval, T, measured using time weighting ‘F’ and quoted to the nearest whole number of
(LA90,T)
decibels.
Residence means a building or part of a building used or capable of being used as a residence.
The value of the A-weighted sound pressure level of a continuous steady sound that within a
Equivalent continuous A-
specified time interval, T, has the same mean-square sound pressure as a sound under
weighted sound pressure
consideration whose level varies with time. The equivalent continuous A-weighted sound pressure
level (LAeq,T)
level is quoted to the nearest whole number of decibels.
A position where there are no reflecting surfaces, other than the ground, close enough to influence
Free field the sound pressure level. Taken as a minimum of 1.2 metres above ground level and 4m from the
closest building façade.
Immission The sound energy received at a receptor point.
Sound characterised by brief excursions of sound pressure (acoustic impulses) that significantly
Impulsive sound exceed the background sound pressure. The duration of a single impulsive sound is usually less
than one second.
An area or place where noise is measured. A list of Sensitive Receptors is defined in EPP (Noise)
Sensitive Receptors
2019 Schedule 1.
Rating Background Level (RBL) is the overall single-figure background level representing each
Rating background level assessment period (day/evening/night) over the whole monitoring period (as opposed to over each
(RBL) 24-hour period used for the ABL). The RBL (or minLA90,1hour) is the level used for assessment
purposes.
Defined objectively in several different ways ranging from the smallest detectable physiological
response to some external stimulus whilst asleep to actual behavioural awakening. Sleep
Sleep disturbance disturbance can also be described subjectively using some appropriate scale after the event. If
there are any effects on mood, attitudes or performance of some task the next day, such variables
could also be measured, both objectively and subjectively.
Sound pressure level Sound Pressure Level (SPL) in decibels is a logarithmic measure of the effective pressure of a
(SPL) sound relative to a reference level of 20 micro pascals (uPA)
Sound Power Level (SWL) in decibels is ten times the logarithm of the ratio of the sound power to a
Sound power level (SWL)
sound power reference level of 1 pico Watt (pW).
Component of the ambient noise (or total noise) that can be specifically identified by acoustical
Specific noise source
means and is associated with a specific source.
Noise that gives fluctuations over a range of not more than 3dB on a sound level meter set to
Steady noise
frequency weighting ‘A’ and time weighting ‘F.’