6 Martin Street NSC-MnrChg-AprvdPlans-Complied
From the archive 6 Martin Street - OPW Application.zip, inside Operational Works Application OPW26/0051 - 1&2/6 Martin Street Peregian Beach. File date in the archive: 2026-01-05 09:58.
RETAININ
G WALL
WATERPROOFING AND DRAINAGE TO
GARDEN
BIN STORE
ENGINEERS AND MANUFACTURERS
OUTDOOR SPECIFICATION
SHOWER BUILT TO
CRAZY PAVE
BO
ACCORD UNDARY WALL
ANCE W S
N USER FIGURED DIMENSIONS. DO NOT SCALE
FROM THE DRAWINGS. CONFIRM ALL
ITH MAN YSTEM & FOOT DIMENSIONS ON SITE PRIOR TO
UFACTUR ING
DESIGN
- FRL 60 ERS ENG S IN CONSTRUCTION OR FABRICATION, ANY
/60/60 INEERS DISCREPENSIES TO BE NOTIFIED TO THE DESIGN
AUTHORITY. IT REMAINS THE CONTRACTORS
RESPONSIBILITY TO ENSURE COMPLIANCE
WITH ALL RELEVANT CODES AND REGULATIONS
IS MAINTAINED AT ALL TIMES. SUBJECT TO
RETAININ
G WALL LEGEND LOCAL COVENANT & BUILDING APPROVAL.
C:\Users\Duncan 2021\Downloads\21-068 - 6 Martin St Peregian - WD - REV H.rvt
ABBR. DESCRIPTION
SLIDING GATE
2452 TILT PANEL
DRIVEWAY GARAGE BBQ BARBEQUE
11/11/2025 2:33:24 PM
D01
DATE ISSUE / AMENDMENT
CONCRETE
EXP. AGG. BIN BIN DRAWER 15.04.2024 H BA ISSUE
D CH 2700 SLAB 03.11.2025 I REVISIONS
STORE
CD CLOTHES DRYER POS. NOTES:
WD-4.02 CT COOKTOP 1). PROVIDE LIFT OFF HINGES TO WC DOORS
REQUIRED BY NCC.
COURTYARD DP DOWNPIPE
2). SMOKE ALARMS TO BE HARD WIRED IN
DW DISHWASHER
STW ACCORDANCE WITH ABCB PART 9.5
GT GATE
EXP. AGG. 3). TERMITE TREATMENT TO BE IN ACCORDANCE
MW MICROWAVE POS. WITH ONE OR MORE METHODS AS SPECIFIED IN AS
D02 SCREEN
920 OHC OVERHEAD CUPBOARD 3660.1 AND ABCB PART 3.4
GARDEN
P EXP. AGG.
EXP. AGG.
P POST 4). SURFACE WATER DRAINAGE TO BE IN
STEPPERS
VOID PPUMP POOL PUMP & ACCORDANCE WITH ABCB PART 3.3.3
OVER EQUIPMENT 5). INSULATION TO BE IN ACCORDANCE WITH ABCB
W06 W07
PTY PANTRY 13.2 OR ENERGY EFFICIENCY REPORT
DP x3 2427SGD 2010 FG
BUILDING OVER 6). BUILT TO BOUNDARY WALLS IN ACCORDANCE
EXP. AGG. SHR SHOWER
GT P P WITH ABCB PART 9.3 & FIRE SEPARATING WALLS IN
GT EXP. AGG. W08 W05 D06 3 4 STAIR PLATFORM SK SINK ACCORDANCE WITH ABCB PART 9.3
2406LV 0618AW OBS 1020 GLASS STW STORM WATER PIT
2
7). SOUND INSULATION OF SEPARATING WALLS AND
1
UP UP
TR TOWEL RAIL SERVICE DUCTS TO BE IN ACCORDANCE WITH ABCB
CH 2950 SLAB
LEVEL OVER
TR
CD TS TOILET SUITE PART 10.7
POLISHED CONC.
LDY * INDICATES SLAB REBATE FOR HEBEL WALL SYSTEM,
GARDEN
CH 2950 SLAB
OHC
SHR 6
5 UBO UNDER BENCH OVEN
WM 7 REFER TO ENGINEERS AND MANUFACTURERS SPEC.
LIVING
2422 MF
2424SGD VB VANITY BASIN
TILES
ENTRY
STDN
FOR DETAILS
D07
8
W04
VB
OFFICE BATH TS 9
10
WM WASHING MACHINE POS. 8). BALUSTRADE TO BE MIN. 1.0m HIGH TO COMPLY
SK
MEDIA CABINET
POLISHED CONC.
LEVEL OVER
D04 WO WALL OVEN
100 STEP
720 C/S
VOID 11 WITH ABCB PART 11.3
OVER 12
PW1 9). POOL FENCE TO BE MIN. 1.2m HIGH TO COMPLY
13
B STW WITH QDC MP 3.4
820 C/S
14
D05
D03
820
10). DOWNPIPE LOCATIONS TO BE CONFRIMED BY
R.C. AWNING OVER
WD-4.01 ROBE CH 2950 SLAB 15
16
17
HYDRAULIC ENGINEER
OHC OHC LEVEL OVER 18 11). FLOOR WASTE GRADES TO COMPLY WITH ABCB
UNIT 1
SD
PTY WO
CT OHC
19 PART 10.2.12 (1:80).
UBO FRIDGE UNIT 2 PARTI-WALL W/ DISCONTINUOUS CONSTRUCTION
(MIN. FRL 60/60/60 & MIN. RW+CTR 50
POLISHED CONC.
KITCHEN CH 2950 SLAB
BIN
DROP CEILING OVER
MW DW SK
LINEN
100 STEP DINING NOOSA COUNCIL
GARDEN
2418SGD
APPROVED PLAN
LEVEL OVER
EXP. AGG.
W03
W02 CH 2650 VJ
132004.4029.02 & RAL22/010 Phone: 07 5493 2587
POOL Email: [email protected]
2446SGD 3 DECEMBER 2025
100 STEP
GLASS POOL FENCE GATE Website: www.dcmbuildingdesign.com.au
W01
QBCC: 15027404
GLASS POOL FENCE POOL
2449SGD SK
EXP. AGG. GATE
R.C. AWNING OVER PROJECT
BBQ
WALL LEGEND UNIT 2 / 6 MARTIN STREET
New Stud Wall (as dimensioned)
ALFRESCO Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
GLASS POOL FENCE
EXP. AGG. PW1 Insulation to external walls to NCC requirements
Existing Wall - Retained
DEEP POOL SHALLOW
OV
ER
Varying construction types
Existing Wall / Column - Demolished PEREGIAN BEACH, QLD
A
(BY OTHERS) OL Varying construction types
RG
PE
SEA
New block wall lined internally
C Internal - Plasterboard to manufacturers spec. CLIENT
T
Battens fixed to block wall (insulation to energy
GA
WD-4.02 efficiency report)
RD
190mm Block wall - as per engineers specification
EN
New block wall unlined
190mm Block wall - as per engineers specification TITLE
New block wall against existing double brick UNIT 2 PROPOSED GROUND FLOOR
wall w/ discontinuous construction
PLAN
EXISTING DOUBLE BRICK WALL
(MIN. FRL 60/60/60 & MIN. Rw+ctr 50)
EXP. AGG. 600 PW1 New 190mm Block wall - as per engineers
STEP
STEP
NEW BLOCK WALL specification - fire rated FRL: 60/60/60
GARDEN DATE
MIN. 50mm gap
03.11.2025
ALU. POOL FENCE
Existing double brick wall wall.
STW OUTDOOR SCALE
As indicated
EXISTING HEBEL & STUD WALL
GARDEN SHOWER New block wall against existing hebel stud wall
EXP. AGG. NEW BLOCK WALL PW2 w/ discontinuous construction (MIN.FRL:
60/60/60 & MIN. Rw + ctr 50) DRAWN CHECKED
PPUMP Internal - Plasterboard to manufacturers spec.
Studs & insulation
SA DC
A Hebel panel PROJ No
GARD
EN WD-4.01
50mm gap
190mm Block wall - as per engineers specification
21-068
1 PROPOSED GROUND FLOOR
EXISTING HEBEL & STUD WALL
PW3 Existing hebel & stud wall convert to MIN. FRL: DRAWING No ISSUE
WD-2.01 I
60/60/60
GT Internal - Plasterboard to manufacturers spec.
SCALE 1 : 100 Studs & insulation
Hebel panel
0 1 2 3 4 5m
Document Set ID: 24368220
Version: 1, Version Date: 10/12/2025