6 Martin Street NSC-MnrChg-AprvdPlans-Complied
From the archive 6 Martin Street - OPW Application.zip, inside Operational Works Application OPW26/0051 - 1&2/6 Martin Street Peregian Beach. File date in the archive: 2026-01-05 09:58.
B
NOOSA COUNCIL
EXISTING UNIT 1 WD-4.01
APPROVED PLAN (IN BACKGROUND)
REMOVE EXISTING WINDOW. WALL CLADDING
132004.4029.02 & RAL22/010 ALTERED TO ACHIEVE FRL: 60/60/60 (TO
NGL + 8.0m
3 DECEMBER 2025 BUILDERS AND CERTIFIER SPECIFICATION)
L1 CEILING
EG
W09
0921 LV/FG/LV
L1 JOINERY
RBL
R.C. SLAB TO ENGINEERS
7655 BUILDING HEIGHT
2550 BED 3
2400
RBL
DETIALS.
FLOATING CONCRETE STAIRS
BAL 2
OPEN PERGOLA
FIRST FLOOR
GF JOINERY
3200 PERGOLA
SH
ALFRESCO
3200
RBL
COURTYARD DINING
2400
LIVING RBL
RBL
BENCH SEAT
RETAINING WALL
GROUND FLOOR
NGL
A UNIT 2 - BUILDING SECTION A
SCALE 1 : 100 C A WALL LEGEND
WD-4.02 WD-4.01 New Stud Wall (as dimensioned)
Internal - 10mm Plasterboard - Paint Finish
External - FC Sheet as noted on elevations
Insulation to external walls to NCC requirements
0m
NGL + 8. Existing Wall - Retained
Varying construction types
Existing Wall / Column - Demolished
Varying construction types
L1 CEILING
LEGEND
ABBR. DESCRIPTION
L1 JOINERY BAL 2 BALUSTRADE TYPE 2 - VERTICAL
W14 D08 SLENDER STEEL
W13 2427SGD 920 GLASS
EG EAVES GUTTER
2550
2400
06075AW OBS
F1.5 1.5M HIGH PC ALUM. FENCE
EXISTING UNIT 1
FIRST FLOOR WIR BED 1 BAL 2
F1.8 1.8M HIGH TIMBER FENCE
RBL RENDERED BLOCK
SH SHOWER HEAD
W07
W06 2010 FG
F1.8
GF JOINERY 2427SGD
W08
D04
ENTRY
3200
720 C/S
2406LV
D02
LIVING
2400
OFFICE 920
2430
RBL F1.5 RBL
GROUND FLOOR
NGL 0 1 2 3 4 5m
DATE ISSUE / AMENDMENT
B UNIT 2 - BUILDING SECTION B PROJECT TITLE
SECTIONS 01
15.04.2024
03.11.2025
H
I
BA ISSUE
REVISIONS SCALE 1 : 100
UNIT 2 / 6 MARTIN STREET
PEREGIAN BEACH, QLD
DATE
03.11.2025
USE FIGURED DIMENSIONS. DO NOT SCALE FROM THE DRAWINGS. SCALE
CONFIRM ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION OR
As indicated
PROJ No
FABRICATION, ANY DISCREPENSIES TO BE NOTIFIED TO THE DESIGN
AUTHORITY. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO
21-068 DRAWN
SA
CHECKED
DC
ENSURE COMPLIANCE WITH ALL RELEVANT CODES AND
DRAWING No ISSUE
REGULATIONS IS MAINTAINED AT ALL TIMES.
SUBJECT TO LOCAL COVENANT & BUILDING APPROVAL.
C:\Users\Duncan 2021\Downloads\21-068 - 6 Martin St Peregian - WD - REV H.rvt
11/11/2025 2:33:42 PM
Phone: 07 5493 2587 Email: [email protected]
Website: www.dcmbuildingdesign.com.au QBCC: 15027404
CLIENT
WD-4.01 I
Document Set ID: 24368220
Version: 1, Version Date: 10/12/2025