Skip to the record
Search everything, all in one place.

Council archive · source document

07/1242 (part 3) - Approved Plans - 05/12/07 [As Published] · 142007.1242

of 64

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
 

  

OS% - OPEN SPACE
{ENVIRONMENT AL,
DRAINAGE AREA)

 

~._ RECTIFY AND MAINTAIN Sen” >
~s. DT EXISTING ACCESS TQ. 997 SO
“RUMP STAION-ONTIL NEW "7S
(CESSES AVAITA

 

‘

NEW CONCRETE ACCESS YO
MATCH EXISTING SEWER

     

 

  

 

      

 

' Sewerage
ELECTRIACL UIT IN THIS Pump, Station
VICINITY. Lor

RPLISISS

   

 

           

ENERGEX EARTHWORKS.

* PAD 3.9mtW) x &.3m(L}
FSL 3.3m

LOCATE EXISTING

 

 

         

ARTICULATED EHICLE TURN AROUND
WITHIN CLEARED VEGETATION AREA,

CONSTRUCT CONCRETE ACCESS
WAY ON EXISTING TRACK
ALIGNMENT AND LEVEL, ~~
MINIMUM WIDTH 3.5m,

'3x600x300 BOX CULVERT
AND HEADWALL TO SUIT.
US iL 2.20

OS IL 2.15

LENGHT = 4.88

GRADE CONCRETE: ACCESS FROM
BOUNDARY. AT 1 in 12 MAX TO
EXISTING TRACK LEVEL,

 

 

 

 

 

 

 

 

 

 

CONSTRUCT COMMERCIAL DRIVEWAY
CROSSOVER JN ACCORDANCE WITH
OWG IPWEA R-0051 AS DETAILEO

CONSTRUCT CONCRETE, PAVEMENT FOR

OS2- OPEN SPACE
(ENVIRONMENTAL AREA)

 

 

             

  

    
  

 

 

 

 

 

 

 

 

 

PUMP STATION ACCESS PAVEMENT DETAILS

rNI2 @ 400
CENTRES PLACED

 

 

 

CONCRETE

| CONCRETE DRIVEWAY TO BE 150mm
[__*~" THKK SL92 MESH 40 TOP COVER

 

 

 

 

ORIVEWAY

 

600

$-—— 300mm SUB BASE GRAVEL (CBR 15 MIN)

 

 

ALL PAVEMENT GRAVEL TO BE
COMPACTED TO 100 PERCENT
RELATIVE DENSITY RATIO
(STANDARD) AS DEFINED IN AS 12897,
U.8.O

 

 

 

 

PAVEMENT DEPTHS MAY BE VARIED BY THE SUPERINTENDENT FOLLOWIN

co Cc NDARD:

ROADWORKS TO 300mm BELOW SUBGRADE 98% STANDARD
ROADWORKS WITHIN 300mm OF SUBGRADE 100% STANDARD
LOT FILL 98% STANDARD
SUB BASE GRAVEL 100% STANDARD
BASE GRAVEL 100% STANDARD

‘CONCRETE TYPES

ORIVEWAY PAVEMENT
EDGE RESTRAINT

N32
N2S

GENERAL NOTES

  

NEW UNDERGROUND POWER IN ACCORDANCE WITH ENERGEX AND
COUNCIL REQUIREMENTS TO EXISTING PUMP STATION AND SHALL
CONNECT TO EXISTING CONDUIT LOCATED AT NORTH EASTERN

CORNER OF EXISTING CONCRETE PLATFORM SURROUNDING PUMP
STATION. NOT SHOWN FOR CLARITY.

   

2, CONNECTION OF NEW UNDERGROUND SERVICE AND CISCONNECTION OF
EXISTING OVERHEAD SERVICE TO BE CARRIED QUT IN ACCORDANCE
WITH THE REQUIREMENTS OF ENERGEX. WORKS TO BE CARRIED OUT
IN A MANNER TO ENSURE NO DISRUPTION TO COUNCILS PUMPING

SYSTEM OCCURS.

3. ALL WORKS AT DEVELOPER'S COSTS.

DRIVEWAY CROSSOVER
4, CONCRETE N32 IN ACCORDANCE WITH AS 1379 AND AS 3600.

5. REINFORCING FABRIC TO AS 1304 LAP FABRIC 250mm.

6 DEPTHS OF CONCRETE AND REINFORCING STEEL SHOWN ARE THE
MINIMUM REQUIREMENTS FOR GOOD FOUNDATION CONDITIONS AND

 

 

OANLEY DOWELMASTER KJ/OM —
150/20/250 WITH RIP-A-STRIP
CAPPING {GREY}

 

PREPARED SUB GRADE 100% COMPACTION

LEVEL MIN CBR OF $ REQUIRED FOR PAVEMENT
SPECIFIED, CONFIRM CBR BY TESTS BEFORE PLACING CBR
1S GRAVEL) REFER TO DESIGN ENGINEER FOR ADDITIONAL
SUB GRADE GRAVEL © CBR TESTS LESS THEN 5,

1G SUBGRAOE TESTING.

N16 TRIMMER

2} 80mm TO OOWEL EACH SIDE

CENTRE

 

 

 

 

 

 

 

 

 

DOWELED CONTROL JOINT MAX 6m CENTRES
(SQUARE) ANO CHANGES IN PAVEMENT WIDTHS.
NOT SHOWN FOR CLARITY.

     
   

    

 

Works Manager, certify that
this drawing complies with Noosa Shire
Council Planning Scheme Policy 6 -
Engineering Desiga Standards - Water &

ai,
tee Date: Wate?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVERAGE TRAFFIC LOADING. WHERE THIS DOES NOT APPLY, DEPTHS
OF CONCRETE AND REINFORCING SHALL BE INCREASED TO SUIT SETO
SPECIFIC CONDITIONS. EASTING WORTHING
294,402 409.776
7. LOCATION OF CROSSOVER TO BE MININUN 1.25m CLEAR OF ESF We-65
STORMWATER STRUCTURES IN KERB. R29 Tait
59 92.555
8. COMPACTION FOR SUBGRADE 95% STANDARD TO AS 1289.5.1.1, sere 5.606
362.210 103.808
9. WHERE SUBGRADE IS LESS THAN CBR 5, EXCAVATE AND PROVIDE 357-309 130.960
IMPORTED MATERIAL TO SATISFACTION OF THE SUPERINTENDENT. «gr 300.593 TOT.64
350.752 103.537
350.01 31.957
a a 10. (LOCATION GF CONCRETE ACCESS ADJACENT EXISTING CONCRETE 332.01 iF
eta , : SLAB OVER AND SURROUNDING PUMP STATION SHALL BE tt K
aLal Sea msgve er =
i. {EE EE gC - te CONFIRMED ON SITE. PROPOSED ACCESS SHALL BE MODIFIED TO 296.878 123.208
a sve %, | e SUIT COUNCIL'S REQUIREMENTS AT THE PUMP STATION.
* { | es 8 5 eB Me
ae ® SCALE 1500 AT At
NOTES; Te: PROXCT: care MARCH 2007 | seu AS SHOWN
1 Ts Hh poet of fh enone. sy ot | SN BARLOW GREGG Waepama. | SEWERAGE PUMP STATION LOT RECONFIGURATION at oa et | oe
Ce ee merely & past B ASK 7) 1A ey MS ACK I OST mS ACCESS LAYOUT PLAN LOT 1 SP 182880 naw war | Palen Barlour
5 ee ae ES an | Male Soetnorcrarmtsonem|| 1Ge 4 emae Rea, EENIE CREEK ROAD oe wee #1990
Pune STW Tafel AREA APEIOED OOS) SEWER Ft ADDED 2. gees tobe precedesce aver sccled C7 oe oma cast TSSRGNTED CORSA TTS NOOSAVILLE PROJECT-SUBSET- SHEET -REVISION
1 [eounck of wonxs ABPROVAL REVISIONS po/oacer | yt 3 Verily all on se. Phone ie tae Cruevan, {KEN HICKS & ASSOCIATES M3048 (62 D
No. Amendment Date |ByjNo. Amendment Date (By ater Prana 696 6572 Ph: O7Sh43 2066 Fox: (07) 5663 76 =

 

 

 

Used in these records

About this file

File size
7.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_1242 (part 3) - Approved Plans - 05_12_07 [As Published].pdf · 7.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document