Bushfire Hazard Management Plan v3                                                                                                                  NCES REF: J000662
Lot 101 on SP142407, Lot 140 on MCH978, Lot 3 on RP137375,
Lot 2 on RP852009 and Lot 8 on RP160703 - 27 Wilgee Court, Cooroy



 PERFORMANCE OUTCOMES                                        ACCEPTABLE OUTCOMES                                 PROPOSED SOLUTION
  b) adequate access for the evacuation of                   around the perimeter of the subdivision, between    is considered unwarranted on the proviso the
     residents and emergency personnel in an                 the created lots and surrounding vegetated lands.   minimum Asset Protection Zones recommended
     emergency situation.                                                                                        herein are implemented.
                                                             OR

                                                             AO8.2                                               Given the limited scale of hazardous vegetation
                                                                                                                 identified adjacent to building envelopes within and
                                                             Fire access tracks are provided between the
                                                                                                                 adjacent to the site, combined with the irregular
                                                             created lots and surrounding vegetated land that:
                                                                                                                 topography including gullies and steep slopes
                                                               a) have a cleared minimum width of 6 metres;      between the building envelopes and retained
                                                               b) have a maximum gradient of 12.5%;              vegetation, the provision of fire access tracks
                                                               c) provide unbroken access for fire fighting      between the hazardous vegetation and the
                                                                  vehicles;                                      building envelopes is considered unwarranted on
                                                               d) provide passing bays and turning areas;        the proviso the minimum Asset Protection Zones
                                                               e) are located within an access easement that     recommended herein are implemented.
                                                                  is granted in favour of Noosa Council and
                                                                  the Queensland Fire and Rescue Service.

                                                             AO8.3                                               All bushfire management measures including
                                                                                                                 prescribed APZ’s are proposed within the site and
                                                             Bushfire management measures are carried out
                                                                                                                 not within any adjoining site.
                                                             on the subject property and not any adjoining
                                                             property.




© 2020                                                                               37
Log in to download the original file

Bushfire Hazard Management Plan OPW20-0051 3 of 3 - Copy.pdf · 8.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.