Original source · versioned page text
Compiled Reference Documents - MCU24/0153 & OPW24/0202
Very large file (10.0 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Given the sandy soil profile and depths of footings required, steel screw piles are considered to be a
suitable foundation type for the proposed unit development generally. However, in areas of cut
exposing medium dense (or denser) sands at the subgrade level conventional high-level footings may be
adopted. It should be noted that excavation for concrete strip footings (or similar) may loosen the base.
Therefore, the use of a vibrating plate and ample water would be required to densify any high-level
footing bases prior to the placement of reinforcing steel.
Due to the presence of loose sands, open bored piers or driven piles are not considered to be suitable
for this site. Steel reinforced concrete bore piles may be possible; however, the use of casings or
sacrificial liners (e.g. formatube etc.) would be required. Cast in place continuous flight auger (CFA) piles
may also be suitable for foundation piles (and shoring piles) provided a small rig capable of traversing
the site can be sourced.
The advice of a specialist piling contractor must be sought regarding feasibility, design and installation of
the piling system for this site, including an assessment of potential vibration effects on nearby structures,
and monitoring requirements.
If steel screw piles are adopted, it will be important to ensure close supervision of installation, as piling
may not encounter sufficient drilling resistance (from torque measurement) in sands at the suggested
founding depth, and piles could extend to much greater depth than necessary.
It is therefore recommended that site specific static load testing be conducted from screw piles, if
adopted, at a minimum. Where tension or compression capacity developed in the footings is critical for
the future structure (e.g. resistance to uplift forces from high winds), then cyclic load tests (including
measurement of deflections under tension and compression cycles) should also be undertaken prior to
construction. Kentledge for static testing, or simulated cyclic loads, should prove the piles to a minimum
of two times the expected working load within tolerable deflections.
Footing design should also account for potential soil reactivity to be equivalent to Class M. It should be
noted that placement of reactive clay (which is not recommended) may result in a more severe equivalent
site classification, such as H1 or greater.
All footings should found such that they are not adversely affected by any adjacent excavations, trenches,
retaining walls, or in ground structures that are not designed to support building loads. Footings should
found at least below a plane extending 1 m horizontally from the base of trenches/excavations/retaining
walls/swimming pool, then rising up at 1V:1H, as illustrated in Text Figure 10 overleaf.
Proposed Unit Development
30 September 2024 | 24265-001-Rev0 14
Document Set ID: 23376055
Version: 1, Version Date: 28/11/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.