100 x 6 mm STEEL EDGING SLEEVES WELDED TO REVERSE
TYPICALLY 350 - 400mm. SPACED 1200mm APART
20mm WITH 30x30 MILD STEEL ANGLE IRON STAKE
TURF AS SPECIFIED
6mm STEEL PLATE WELDED ACROSS JOIN MULCH AS SPECIFIED
STAKES ARE WELDED TO
EDGE TO PREVENT
VERTICAL MOVEMENT
TIMBER SPECIFICATION: SECTION
UNSEASONED HARDWOOD, CLASS 1 SELECT GRADE F17, ACQ OR TANALITH E MIN. H4
TREATMENT, WITH ONE COAT OF TIMBER COATING.
GALVANISED TIMBER
4 STEEL EDGE (CORTEN) N.T.S.
FIXING SCREWS, TYP. LD4 Typical Detail
STREET TREE PLANTING DETAIL PLAN STEEL EDGE. WASHED GRAVEL
NOTES: REFER TO DETAIL AS SPECIFIED
EXTENT OF TREE PIT EXCAVATION TO BE 1800mm x 1800mm IN AREA, MINIMUM
(SUBJECT TO FOOTPATH LOCATION). REMOVE ALL EXCAVATED FILL OFF-SITE. GARDEN AS SPECIFIED
ELEVATION
150
50mm x 150mm H4 F14 HARDWOOD TIMBER TOPSOIL AS
EDGE, REFER DETAIL, TYPICAL. SPECIFIED, FINISH 100mm
HARDWOOD BELOW TOP OF EDGE TO
STAKES (2), 1200mm, MAXIMUM ALLOW FOR MULCH
SEE SECTION
2x HOT DIPPED GALVANISED TRIPLE GRIP PLAN
STREET TREE, SCREW TO FIX MITRED TIMBER EDGING
REFER DETAIL TOGETHER, TYPICAL.
BELOW. 100 x 50 mm TIMBER EDGING 50 x 25 x 450mm HARDWOOD PEG
ROOTBALL 20mm
@1200mm CENTRES 5 GRAVEL PLACEMENT - PLASTIC EDGE N.T.S.
KERB INVERT
TURF AS SPECIFIED LD4 Typical Section
MULCH AS SPECIFIED
ROAD
FIX EDGING WITH 3x F14 HARDWOOD 2x HOT DIPPED
50mm x 25mm x 450mm STAKES, WITH 2x GALVANISED TRIPLE GRIP
GALVANISED NAILS TO FIX STAKES TO SCREW TO FIX MITRED
1800mm
TOPSOIL WITH EDGING, TYPICAL. TIMBER EDGING
MULCH ABOVE TOGETHER, TYPICAL. SECTION
EDGING TO EXTEND TO FOOTPATHS WHERE
WIDTH VARIES REFER TO DWG'S
APPLICABLE WITH STREET TREE
CENTRALLY LOCATED WITHIN GARDEN
(ALLOWING FOR SERVICES SETBACKS),
2 HARDWOOD TREATED GARDEN EDGE N.T.S. MULCH
ALL EXPOSED
BLOCKWORK TO BE
REFER TO PLANS FOR PATH LOCATIONS. LD4 AS SPEC.
Typical Detail NOM 30mm 'A' HORIZON PLANTER SOIL AS SPEC. TREATED AS PER
190mm FINISHES SCHEDULE
'FIGURE 8' HESSIAN TREE TIE, TYPICAL. IRRIGATION
CONDUIT 200
COREFLUTE OR
EQUIVALENT PROTECTION
CENTRE TREE, 900mm FROM BACK OF KERB, OR BETWEEN KERB & FOOTPATH AS APPLICABLE. GARDEN AREAS TO BOARD TO PLANTER SIDES
EXTEND FROM BACK KERB TO FOOTPATH, TYP. OVER MEMBRANE TO
40mm CAP
REFER TO DWG'S
WATER PROOFING
HEIGHT VARIES
CONSULTANTS SPEC
NOTES:
ENSURE CROWN OF ROOTBALL LEVEL IS
SET HIGHER THAN ADJACENT FINISHED PLANTER MASONRY
GROUND LEVELS TO PREVENT EXCESSIVE WALLS TO STRUCTURAL
PONDING AROUND ROOTBALL. WHEN ENGINEER SPEC
NOTES:
FOOTPATH IS ADJACENT TO STREET TREE ENSURE CROWN OF ROOTBALL LEVEL IS
INSTALL ROOT BARRIER TO FOOTPATH SET HIGHER THAN ADJACENT FINISHED
SIDE OF PLANT PIT AS PER NOTES ABOVE. GROUND LEVELS TO PREVENT EXCESSIVE
PONDING AROUND ROOTBALL.
PODIUM SLAB PODIUM SLAB
FULL & EVEN CROWN, TYP. FULL & EVEN CROWN, TYP.
DRAINAGE CELL (30mm
WATERPROOF MEMBRANE
ATLANTIS DRAINAGE
50mm WIDE HESSIAN TREE TIES WRAPPED 50mm WIDE HESSIAN TREE TIES WRAPPED AND ROOT BARRIERS TO TOPPING SLAB (IF
CELL OR EQUIVALENT)
LOOSELY AROUND TRUNK, THEN A FIGURE 8 & LOOSELY AROUND TRUNK, THEN A FIGURE 8 & WATER PROOFING NECCESARY) NOM. 55mm.
SECURED TO STAKE WITH GALVANISED NAILS SECURED TO STAKE WITH GALVANISED NAILS CONSULTANT SPECIFICATION REFER TO STRUCTURAL
OR STAPLES. POSITION TREE TIE BETWEEN OR STAPLES. POSITION TREE TIE BETWEEN ENGINEER FOR DETAIL
1/3 TO 1/2 OVERALL HEIGHT OF TREE. PODIUM DRAINAGE
1/3 TO 1/2 OVERALL HEIGHT OF TREE.
REFER TO HYDRAULIC
2 - 50 x 50 x 2400mm F14 HARDWOOD ENGINEERING DRAWINGS
2 - 50mm x 50mm x 2400mm F14 HARDWOOD
CENTRALLY POINTED NON-TREATED STAKES. FOR DETAIL
CENTRALLY POINTED NON-TREATED STAKES
(SHOWN PERPENDICULAR TO KERB FOR STAKES TO BE DRIVEN VERTICALLY INTO
GRAPHIC CLARITY ONLY). STAKES TO BE GROUND OUTSIDE OF THE ROOTBALL &
DRIVEN VERTICALLY INTO GROUND OUTSIDE SHALL HAVE A FINISHED HEIGHT LOWER
OF THE ROOTBALL & SHALL HAVE A FINISHED THAN THE TREES LOWER LATERAL LIMBS. 6 PLANTER ON PODIUM N.T.S.
HEIGHT LOWER THAN THE TREE'S LOWER
FORM SHALLOW SAUCER SHAPED LD4 Typical Section
LATERAL LIMBS.
DEPRESSION AROUND BASE OF PLANT.
FORM SHALLOW SAUCER SHAPED KEEP MULCH NOM. 50mm FROM TRUNK
900mm
DEPRESSION AROUND BASE OF PLANT. KEEP 900mm 900mm BASE.
min. 900mm MULCH NOM. 50mm FROM TRUNK BASE.
100mm DEEP ORGANIC MULCH AS 100mm DEEP ORGANIC MULCH AS
NOMINATED. MOUND MULCH AT EDGE OF NOMINATED. MOUND MULCH AT EDGE OF
2 x POT Ø. PLANT PIT TO COLLECT WATER TO FALL 2 x POT Ø PLANT PIT TO COLLECT WATER TO FALL PLANT PIT 2X WIDTH OF 2x POT Ø SHRUB / GROUNDCOVER / TUFTY
DOWN EDGES OF PLANT PIT. DOWN EDGES OF PLANT PIT. DO NOT MULCH RESEPCTIVE POT. SCARIFY ALL
POT Ø POT Ø GRASS PLANT SPECIES PER PLAN
WITHIN 50mm OF PLANT STEM. PIT WALLS & BOTTOM, TYP.
TURF AS SPECIFIED. POT Ø
TURF OR GARDEN, REFER TO PLAN.
BACKFILL PLANT PIT WITH 100mm ORGANIC MULCH PER AS
TIMBER EDGE DETAIL. TOPSOIL AS PER GENERAL NOTES, SPECIFIED, KEEP MINIMUM 50mm
SPADE EDGE, REFER TO DETAIL. AVOID COMPACTION, TYP. FROM PLANT STEM. FORM SHALLOW
TREE PIT TO BE EXCAVATED TO NOMINAL DISH DRAIN TO BASE OF PLANT, TYP.
TOPSOIL PROFILE AS PER GENERAL NOTES GARDEN BED TOPSOIL AS
DEPTH OF 600mm. BACKFILL HOLE WITH PROJECT SPECIFICATIONS. PER GENERAL NOTES, AVOID
600mm
TOPSOIL PER SPECIFICATIONS FIRMING
TREE PIT TO BE EXCAVATED TO NOMINAL COMPACTION, TYP.
PROGRESSIVELY. ALL EXCAVATED FILL TO
200mm 150mm 300mm
BE REMOVED OFF SITE. DEPTH OF 600mm. BACKFILL HOLE WITH
DEPTH VARIES
100mm, TYP.
100% TOPSOIL PER SPECIFICATIONS FIRMING
COMPACTED SOIL UNDER TREE PROGRESSIVELY. EXCESS EXCAVATED SOIL 10mg TERRAFORM PRODUCT
TO BE REMOVED OFF SITE. GRANULES
PROVIDE CLEAN CONNECTION TO ROAD 2x ROOTBALL
SCARIFY PIT WALLS & CULTIVATE PIT
DRAINAGE AS ADVISED ON SITE BY CIVIL DEPTH, TYP.
BOTTOM 150mm, TYP.
ENGINEER. TYPICAL: 100mm DEEP UNIFORM
GRAVEL LAYER. TERRACOTTEM UNIVERSAL SOIL CONDITIONER. 150mm, TYP. 150mm DEEP CULTIVATED
ONE APPLICATION WHEN PLANTING AS PER SUBGRADE, OR AS PER
150mm CULTIVATED SUBGRADE & PIT WALLS. MANUFACTURES RECOMMENDATIONS EXISTING SUBGRADE, TYP. GENERAL NOTES, TYP.
TERRACOTTEM UNIVERSAL SOIL CONDITIONER.
ONE APPLICATION WHEN PLANTING AS PER COMPACTED SOIL UNDER TREE
MANUFACTURES RECOMMENDATIONS
1 STREET TREE PLANTING - TIMBER EDGES N.T.S. 3 TREE PLANTING - in GARDEN or TURF N.T.S. 7 POTTED SHRUB, GROUNDCOVER OR TUFTY GRASS PLANTING
LD4 Typical Section Detail LD4 Typical Section LD4 Typical Section Detail N.T.S.
anembo consultants
Client: Location: Project Description: Drawing Title: JOB No.: S24111298
FILE: 250321 D 21.03.25 ARCH BASE UPDATE CK TH
ArchEnd 51 Elanda St, Sunshine Beach Landscape Works DWG. No. LD5 C 27.11.24 COUNCIL SUBMISSION CK TH
anembo consultants pty.ltd. A.B.N. 75 089 473 156
SHEET 5 OF 10 B 21.11.24 FOR REVIEW CK TH This document is the copyright of anembo consultants & shall PO Box 24 Moffat Beach Q 4551 Landscape Architects
Development: Lot on Plan: Project Status: APPROVED:
A 11.11.24 FOR REVIEW CK TH
not be copied without written approval, nor shall it be used Ph: 07 5437 0000 Project Management
T Hindley AILA 713 except for the development and the site specified. Scale can email: [email protected] Environmental
Development Lot 403 on RP 48112 Landscape Operational Works TYPICAL DETAILS CATEGORY: MHD ISSUE DATE DESCRIPTION DWN CKD ISSUE DATE DESCRIPTION DWN CKD
not be guaranteed when printing from PDF files. www.anembo.com Arboriculture