S
-
S
>
APPROVED PLAN
REFER TO BASEMENT PLAN
MCU24/0153 & OPW24/0202
S
FOR STORMWATER SYSTEM
>
>
UNDER BASEMENT LEVEL NOOSA COUNCIL
S
3-3 15 DECEMBER 2025
>
>
2.0m x 2.5m x 1.0m DEEP CONCRETE
S
DETENTION TANK. MIN. 5.0m3
S
REQUIRED STORAGE VOLUME.
>
>
S
>
>
S
>
1-2
>
6-1
S
S
>
>
S
>
>
REFER TO BASEMENT LAYOUT
S
DRG C011
4-3 1-5
>
S
S
>
REFER TO SHEET 017 FOR VEHICLE
TRACKING LONGITUDINAL SECTION.
S
>
S
>
S
S
3-3
>
A4
04
S S
8
45.
1-2
0
46.
8-1
S
>
2
46.
6-1
.96
4
46.
43
>
T
6
EN
46.
7-1
S
3 M
8
3.6
E
46.
AS
4-3
4
0
B
47.
CONNECT TO EXISTING TO
2
47.
STORMWATER INLET PIT AY
S
4
REFER TO ARCHITECTURAL
47.
W
VE PLANS FOR BUILDING DESIGN
6
I
47.
DR
8
47.
S S S
0
8-1
48.
ENLARGEMENT
43.2
6
2
.9
48.
43
7-1
43 .4
43 .6
4
43
.63
48.
SCALE 1:50 ACO K300 KLASSIKDRAIN
44 .8
43
44.2.0
OR SIMILAR APPROVED 6
48.
TO CONNECT TO 2-1
4 4.4
4 4.6
8
45.40.8
48.
4
0
49.
4 5.2
LID TO BE LIFTED 100mm REFER TO
45.56.4
ACO K300 KLASSIKDRAIN 5-1
4
ABOVE DESIGN SURFACE
LEGEND
OR SIMILAR APPROVED ENLARGEMENT
TO CONNECT TO 1-4
49.2
2-1
45.8
EXISTING POWER POLE TO BE RELOCATED
46.0
OR MAIN TO BE RELOCATED UNDERGROUND.
1-1
46.2
SUBJECT TO ENERGEX APPROVAL.
46.4
REINSTATE VERGE AND
49.4
HANDRAILS NOT TO BE
46.6
KERB TO MATCH EXISTING EXISTING CONTOURS
INSTALLED ADJACENT TO
46.8
SERVICING AND ACCESS AREAS EXISTING BUILDING
(LOCATION INDICATIVE) EXISTING KERB AND CHANNEL
PROPOSED VEHICLE CROSSOVER
47.0
IN ACCORDANCE WITH IPWEA STD .6
5.4
49 EXISTING FENCE
DRG RS-049 & RS-050
0m
47.2
VISITORS PARKING 4-1 EXISTING TELSTRA
T
47.4
W
OE EXISTING OVERHEAD ELECTRICAL
47.6
W W EXISTING WATER
47.8
4.
49.
00
S
48.0
6 EXISTING SEWER
m
W
EXTERNAL FOOTPATH RAMP AND STAIRS NOTES: EXISTING TELSTRA PIT
49.6
48.2
ACO K100 KLASSIKDRAIN WITH WM EXISTING WATER METER
W
1. THE EXTERNAL FOOTPATH, RAMP AND STAIRS SHALL BE
5.
HEELSAFE GRATE OR SIMILAR
PROPOSED CONTOURS
48.4
00
APPROVED TO CONNECT TO 46.0
m
STRUCTURE 4-1
CONSTRUCTED IN ACCORDANCE WITH AUSTRALIAN STANDARDS AS
ADJACENT BOUNDARY
48.6
W
0m 1428.1-2001, AS1428.2-1992, AND THE PROPOSED DESIGN.
1.5
2.5
2. WARNING TACTILE INDICATORS (TGSIs) ARE TO BE PLACED AT THE PROPOSED BOUNDARY
m
48.8
PROPOSED 2.5m WIDE
W
CONCRETE FOOTPATH
TOP OF ALL RAMPS AND STAIRS AND AT THE TOP AND BOTTOM OF PROPOSED STORMWATER PIPE
ALL RAMPS AND STAIRS WHERE THE LANDING WIDTH EXCEEDS 3.0m
49.0
EL
AN
WIDE. TACTILE INDICATORS ARE TO BE PLACED IN ACCORDANCE PROPOSED STORMWATER PIT
DA
49.2
W
ST
WITH AS1428.4 - 2009. RETAINING WALL (BY OTHERS)
RE
HANDRAILS NOT TO BE
ET
3. CAMBER AND CROSSFALL MUST NOT EXCEED 1:40 IN ACCORDANCE
INSTALLED ADJACENT TO > > > PROPOSED SWALE
W WITH AS1428.1-2001
SERVICING AND ACCESS AREAS
. 50m 49.2
(LOCATION INDICATIVE)
4. STAIRS AND RAMPS ARE TO BE SLIP RESISTANT SURFACES IN PROPOSED CONCRETE PAVEMENT
0 ACCORDANCE WITH AS 4586-2013 AND HB 197:1999
PROPOSED FOOTPATH
PROPOSED 1.5m WIDE
CONCRETE FOOTPATH PROPOSED BITUMEN PAVEMENT
PAVEMENT CUTBACK EXTENT
PROPOSED TYPE 2 HANDRAIL IN ACCORDANCE WITH
MATCH NEATLY TO IPWEA STD DRG. GS-044 OR OTHER SIMILAR
EXISTING FOOTPATH PRODUCT NOMINATED BY ARCHITECT AND
APPROVED BY COUNCIL AND TO COMPLY WITH
CLAUSE 10 OF AS 1428.2-1992 ACCESS AND MOBILITY
.53
49
North Point Approved Project Address Sheet Title
E WHITMORE
N RPEQ 31423
51 ELANDA STREET SUNSHINE BEACH QLD
SITEWORKS OVERALL LAYOUT GROUND
For and on behalf of RECOR Pty Ltd.
Scale 1.0 0 1.0 2.0 ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SCALE (metres) SUNSHINE COAST | BRISBANE | SYDNEY
B 26/09/25 ISSUE FOR OPW APPROVAL DP AY
1 0
1 : 50 (FULL SIZE)
1 2 3 4 5
www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE A1
A 21/03/25 ISSUE FOR APPROVAL TVZ AY SCALE (metres) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
1 : 100 (FULL SIZE) drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK in the revision description. 20240127 010 B
Document Set ID: 24193100
Version: 1, Version Date: 01/10/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU24-0153 & OPW24 0202Related documentApplication case desk ↗
About this file
- File size
- 30.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.