132007.2446.05 - Request For An Other Change To An Existing Development Permit For Material Change Of Use - Visitor Accommodation Type 4 Conventional (Visitor Hostel) To Include 11 Additional Beds At 102 Pacific Avenue Sunshine Beach · Attachment 4 - 132007.2446.05 - Proposal Plans
Plans and drawings: the text below has words only, no drawings.
ATTACHMENT 4 - (132007.2446.05) - PROPOSAL PLANS
EXIST. GROUND FLOOR HOSTEL ACCOMM. EXISTING HOSTEL ACCOMM.
4400 7600 3000 3000
EMT A
H 3400 EXIST. SEWER
RT
O
N 45.253 133°0'0"
exist.
3000
3884
4500
EXISTING LANDSCAPING EXISTING LANDSCAPING
EXIST. 1.0M WIDE LANDSCAPED
EXISTING
7200
STRIP TO BOUNDARY
BLOCK A 2286
PROPOSED
1ST FLOOR
HOSTEL PATHWAY
ACCOMMODATION
EXISTING LANDSCAPING
Existing EXISTING
33.595 43°0'0"
19200
BLOCK B
PATHWAY TO EXISTING
43°0'0"
EXISTING
FACILITIES
EXTENT OF PROPOSED BLOCK C EXISTING POOL
1ST FLOOR ROOF OVER & DECK
33.603
2600
Council annotation: omp
Location and extent of PATH
3400 WAY
Acoustic fence. Height, extent
wall
and building material to be in EXIST.
accordance with condition 110 PARK
ING
ENTRY
of the approval. BIKE
PARK PARK ROOFED RACKS
5400
1 2 COMMUNAL
AREA PARK
ING DISABLED
9284
PARKING
PARK
COMMUNAL ING
EXIST. AREA PARKING
4500
EX
Y
DRIVEWAY
BINS (11)
NL
IST
MINIBUS
YO
500
.E
TR
XIT
45.253 133°0'30"
EN
SITE DETAILS
ON
CONCRETE FOOTPATH
T.
LY
IS
EX EXISTING
LOT NO: 162 SP307694 & EMT A RP 897370 EXISTING
LANDSCAPING
BLOCK WALL
ADDRESS: 102 PACIFIC AVE, SUNSHINE BEACH
L/A: NOOSA COUNCIL
SITE AREA: 1520m2
PROPOSED
USE: VISITOR ACCOMMODATION TYPE 4 - HOSTEL
EXISTING DRIVEWAY PACIFIC AVENUE
SITE PLAN
SCALE 1 : 200 FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
SITE PLAN - CONCEPT
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
P3 Amendment Information Response 21.02.2025 Do not scale off drawings. Scale As indicated DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn JG Designed JG A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-01
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved POD Rev: P3
Plot Date: 20/03/2024 1:54:52 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 6 pages
Page 2
7600 1800
9400 12800 9400
SITE COVERAGE
EXISTING GROUND FLOOR AREAS:
230 4300 70 1200 70 1500
BLOCK A = 95.4m²
BLOCK B = 188.77m2
WALKWAYS & ENTRY = 76.2m²
SUB TOTAL = 360.37m²
EXISTING
BLOCK A BLOCK C = 165.12m2
3000
EXIST. WC
3911
CARPORT/OUTDOOR = 39.0m2
MANAGER'S UNIT 95.4m2 WALKWAY = 25.2m2
SUB TOTAL = 229.32m2
GROUND FLOOR =95.4m2
70
TOTAL GR. FL (38.8%) = 589.69m2
8500
SITE AREA = 1520m2
3210
40% Site coverage = 607.76m2
230
WALKWAY
EXIST.
8 BED DORM EXISTING
BLOCK B
19200
EXISTING
6000
WALKWAY
BLOCK C GROUND FLOOR =188.77m2
B GROUND FLOOR = 165.12m2
23110-06
ROOFED
230
WALKWAY WALKWAYS
25.2m2 EXISTING POOL = 65.6m2
& DECK
13199
6000
EXIST.
8 BED DORM
230
EXIST.
ENTRY
10.5m2
CARPORT COMMUNAL AREA
39.0m2 Council annotation:
A This approved plan relates to
23110-06 132007.2446.05 for upper level of
Block C only.
FLOOR PLAN FOR INFORMATION ONLY
SCALE1 : 125 NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
GROUND FLOOR PLAN -
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
EXISTING
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
Do not scale off drawings. Scale 1 : 125 DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn JG Designed JG A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-02
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved POD Rev: P2
Plot Date: 20/03/2024 1:22:50 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
Document Set ID: 22882418
Version: 1, Version Date: 25/03/2024
Page 3
90 4604 70 2770 230 1710 90 SITE COVERAGE
1ST FLOOR AREAS:
90 5605 70 2770 230 1710 90 EXISTING BLOCK A = 92.16m2
EXISTING BLOCK B = 170.89m2
WALKWAYS & STAIRS = 56.00m2
SUB TOTAL = 319.05m2
116
PROPOSED BLOCK C 1ST FLOOR AREAS:
Screens to
STORE 4200 EXISTING
windows
ACCOMM. UNITS = 166.4m2
BATH BLOCK A WALKWAYS & STAIRS = 27.0m2
92.16m2 SUB TOTAL = 193.4m2
6410
TOTAL 1ST FLOOR (33.71%) = 512.4m2
8 BED DORM BATH
(29.4m²)
230
WALKWAY
PROPOSED
BLOCK C EXISTING
FLOOR AREA = 166.4m2 BATH BLOCK B
6000
WALKWAY
21699
WALKWAY 170.89m2
27m2
B 8 BED DORM BATH
(33.6m²) 56m2
23110-06
230
8 BED DORM
(34m²) BATH
Council annotation:
6140
This approved plan relates to
BATH 132007.2446.05 for upper level of
Block C for maximum 11
additional beds only.
90
90 5605 70 1200 70 1500 230 1800
8765 1800
A
23110-06 8400
7319
1ST FLOOR
SCALE1 : 125 FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
1ST FLOOR - CONCEPT
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
Do not scale off drawings. Scale 1 : 125 DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn JG Designed JG A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-03
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved POD Rev: P2
Plot Date: 20/03/2024 1:23:58 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
Document Set ID: 22882418
Version: 1, Version Date: 25/03/2024
Page 4
PROPOSED 1ST FLOOR
Council annotation:
This approved plan relates to
Slatted screens
132007.2446.05 for ground level parking
EXISTING HOSTEL
to 1st floor windows and upper level of Block C.
Colorbond roof sheeting
to match existing.
ceil
Rendered finish
to match existing
2700
600 Existing Outdoor Area
1st
7481
ceil
ce
2700
groun
lower floo
Existing Landscaping
to remain
PACIFIC AVENUE ELEVATION
SCALE 1 : 100 Council annotation:
Colorbond roof sheeting
to match existing. All upper floor windows to be non opening and
Slatted screens
to 1st floor windows screened to ensure no overlooking to adjoining
sites.
Rendered finish
to match existing
8000
Existing Outdoor Area
Existing roofline to
ground floor units SHS support posts
1st floor
7481
ceiling 2
7770
6.05m ceiling 1
2700
2400
1800
2700
2400
ground floor
PUBLIC lower floor level
6000 FOOTPATH
NORTHERN ELEVATION
SCALE 1 : 100 FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
ELEVATIONS - SHEET 1
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
CONCEPT
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
Do not scale off drawings. Scale 1 : 100 DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn JG Designed JG A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-04
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved POD Rev: P2
Plot Date: 20/03/2024 1:28:54 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
Document Set ID: 22882418
Version: 1, Version Date: 25/03/2024
Page 5
PROPOSED 1ST FLOOR
Colorbond roof sheeting ACCOMMODATION Rendered finish
to match existing. to match existing
ceiling 3
LANDSCAPING
2700
STRIP EXISTING ROOFED
COMMUNAL AREA
1st floor
7481
200
ceiling 2
2700
ground floor
lower floor level
Existing roofline to
EXISTING GROUND FLOOR ground floor units
HOSTEL ACCOMMODATION
Council annotation:
SOUTHERN ELEVATION All upper floor windows to be non opening and
SCALE 1 : 100 screened to ensure no overlooking to adjoining PROPOSED 1ST FLOOR
EXISTING
sites. EXISTING
HOSTEL HOSTEL Colorbond roof sheeting Slatted screening Rendered finish
BLOCK B BLOCK A to match existing. to windows to match existing
ng 3 ceiling 3
2700
2700
1st floor 1st floor
ceiling 2
200
ceiling 2
2700
2700
ground floor ground floor
EXISTING GROUND FLOOR
HOSTEL ACCOMMODATION
EASTERN ELEVATION
SCALE 1 : 100 FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
ELEVATIONS - SHEET 2
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
CONCEPT
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
Do not scale off drawings. Scale 1 : 100 DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn Author Designed Designer A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-05
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved Approver Rev: P2
Plot Date: 20/03/2024 1:55:36 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
Document Set ID: 22882418
Version: 1, Version Date: 25/03/2024
Page 6
Colorbond roof sheeting
to match existing
Proposed Fire Fire rated
rated floor dividing walls Slatted screens to
1st floor windows
ceiling 3 ceiling 3
NEW 1ST FLOOR
8 BED DORM 8 BED DORM 8 BED DORM
2700
34m2 33.6m2 29.4m2
2100
1st floor 1st floor
7370
6677
ceiling 2 ceiling 2
EXISTING
EXISTING
2700
GROUND FLOOR
ground floor ground floor
lower floor level
Line of existing ground
floor roof to be removed.
SECTION A
SCALE1 : 125 23110-02
A
23110-06
Colorbond roof sheeting
to match existing
Slatted screens to
1st floor windows NEW 1ST FLOOR
EXISTING HOSTEL
ceiling 3 ceiling 3
NEW
WALKWAY
Balustrade to EXISTING EXISTING
8 BED DORM BATH
2700
match existing
BLOCK A BLOCK B
Proposed Fire
1st floor 1st floor
7481
rated floor
ceiling 2 ceiling 2
EXISTING
2700
SHS support posts
GROUND FLOOR
ground floor ground floor
lower floor level lower floor level
SECTION B
SCALE1 : 125 23110-02
FOR INFORMATION ONLY
NOT FOR CONSTRUCTION
Drawing Revisions
Note: * indicates signatures on original issue of drawing or last revision of drawing
Construction Notes
All construction to be in accordance with the current BCA, Qld Building Act,
Client FLASHPACKERS NOOSA Title
SECTIONS
PJ
relevant Aust. Stds, QDC and relevant Local Govt reqts.
Builder or contractor is to verify all dimensions and details before the
commencement of any work and notify designer of any discrepancies. concepts Project HOSTEL 102 PACIFIC AVE,
All dimensions shown in millimetres u.n.o.
& designs SUNSHINE BEACH
Do not scale off drawings. Scale 1 : 125 DO NOT SCALE
Original Size
Drawing No:
P2 ISSUED TO CLIENT 19.03.24 PJ concepts & design Pty Ltd PH. 0438 945 935 Drawn JG Designed JG A3
P COMMENTS 09.01.24 Conditions of Use. This document may only be used by PJ's client (and any other
person who PJ concepts & designs has agreed can use this document) for the PH. 0410 627 589 ABN 80 130 019 288 This Drawing must not be used for Construction unless signed as Approved 23110-06
No Revision Date
purpose for which it was prepared and must not be used by any other person or for
any other purpose.
E. [email protected] QBCC LIC 1264 308
Approved POD Rev: P2
Plot Date: 20/03/2024 1:43:07 PM Cad File No: Z:\PJ CONCEPTS & DESIGNS\Flashpackers\2023\FLASHPACKERS_additions.rvt
Document Set ID: 22882418
Version: 1, Version Date: 25/03/2024
Page 7
5400
500
B85Vehicle(Real
istcminradius)(2
3200
4.91 1999
0 4) B85 Vehicle (Realistic min radius) (20 4)
800
B85 Vehicle (Realistic min radius) (20 4)
0.92 2.8
B85 Vehicle (Realistic min radius) (2004)
Overall Length 4.910m
Overall Width 1.870m
Overall Body Height 1.421m
Min Body Ground Clearance 0.159m
Track Width 1.770m
Lock to Lock Time 4.00s
Curb to Curb Turning Radius 5.750m
B85 Swept Path Assessment 102 Pacific Av, Sunshine Beach
Australian Standard AS/NZS2890.1:2004 Drawing No: BMC25053-ATR01 Version: 1
(07) 3398 4649
www.bmctraffic.com.au
Scale 1:100 at A4 Prepared By: Beth Meehan RPEQ #8373 Date: 21/02/2025
Used in these records
132007.2446.05 - REQUEST FOR AN OTHER CHANGE TO AN EXISTING DEVELOPMENT PERMIT FOR MATERIAL CHANGE OF USE - VISITOR ACCOMMODATION TYPE 4 CONVENTIONAL (VISITOR HOSTEL) TO INCLUDE 11 ADDITIONAL BEDS AT 102 PACIFIC AVENUE SUNSHINE BEACH · ATTACHMENT 4 - 132007.2446.05 - PROPOSAL PLANSAttachmentsMeeting 897 · read item & discussion ↗