secure piled foundations approximately 10-12m further down slope. The
western contiguous piled retaining wall could be more economically
constructed using temporary tie-back ground anchors installed into the
adjacent properties, but it may not be possible to obtain permission from
those owners to do this.
The combination of cantilevered and strutted contiguous piled walls
throughout the building works will not only provide very stable working
platforms during the construction stage, but will also greatly enhance the
completed building's capacity to resist lateral loads and add significantly
to the stability of all areas uphill of the proposed works by limiting the
extent of any future surface sand slips.
Once the contiguous piled walls are completed and fully strutted where
required, the remainder of the reinforced concrete structure can be readily
constructed on a safe and stable building platform using traditional
formwork and cast-insitu methods.
3.2 General
the proposed residence comprises the following:
• Two living levels to the main residence
• Access driveway at road level/roof level.
• External terraced areas, pool and access corridors
3.3 Site Conditions
The information discussed below has been interpreted from the
geotechnical reports by Morrison Geotechnical (dated September 2009)
and SCG Consulting Engineers dated 24 March 2009.
In brief, boreholes drilled across the site encountered fairly consistent
tipper layer conditions comprising loose sands gradually increasing in
density with depth. Deeper surface conditions vary across the site from
dense sands to very stiff sandy clays overlying extremely weathered
sandstone at approximately RL33.
Ground water seepage and springs are likely to be encountered at any hard
impermeable layers following wet weather.
Due to the topography of the site all precautions must be taken to
minimise risk of surface sand slips and possible flow of loose surface
sands from excavated trenches and building platforms.
Surface sands are very loose and slope at gradients of between 23° and
32°.
The additional Geotechnical information provided in the Morrison
Geotechnical Report to 22.4m depth will be used to further develop the
structural design, and refine construction procedures.
5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0169 Information Response to DERM - 71 Seaview Terrace Sunshine BeachRelated documentApplication case desk ↗
About this file
- File size
- 14.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.