EXISTING BALCONY OVER EXISTING BALCONY OVER
(CONCRETE SLAB) (CONCRETE SLAB)
EXISTING BEDROOM EXISTING BEDROOM
EXISTING SLIDING GLASS DOOR NEW SLIDING GLASS DOOR
NEW WALL EXTENSION
EXISTING EXTERIOR VIEW PROPOSED EXTERIOR VIEW
ISSUE DESCRIPTION DATE CLIENT DESIGN KJ CHECKED KJ
BUILDER A PRELIMINARY DRAWINGS 12.10.21 D. ALLEN
PROJECT
KIERON JAMES DESIGN UNIT 2 FLOOR AREAS
DRAWN
SCALE
KJ ISSUE
SHEET
A
BUILDING DESIGN & DRAFTING
PROPOSED ALTERATION/ADDITION MOBILE: 0417 633 275 N.T.S. A3 1 OF 10
EXISTING UNIT 2 92.6 m²
UNIT 2/33 P.O. BOX 483 COOLUM BEACH QLD 4573 TERRACE 39.1 m²
DWG NUMBER DATE
NOOSA DRIVE EMAIL: [email protected]
ALTERATION 8.4 m² 21-121 12.10.2021
Grand total 140.1 m² ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH
C COPYRIGHT THIS DRAWING REMAINS THE PROPERTY OF KIERON JAMES DESIGN & IS PROVIDED FOR THE USE AS DESCRIBED AND MAY
NOOSA HEADS MEMBER BDAQ : QBCC LICENCE No. 81726 THE BUILDING CODE OF AUSTRALIA and QUEENSLAND DEVELOPMENT CODE
NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. STANDARD BUILDING REGULATIONS and TIMBER FRAMING CODE AS 1684
Document Set ID: 21651747
Version: 1, Version Date: 19/10/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
REAL PROPERTY DESCRIPTION
LOT NO: 2
RP/SP: RP123877
PARISH: WEYBA
COUNTY: MARCH
SITE AREA: 715.32 m² -
LOCAL AUTHORITY:
CONTOURS:
NOOSA COUNCIL
0.25m
APPROVED PLAN
DATUM: ASSUMED 51901.3961.01
NOOSA COUNCIL
SITE COVERAGE: 42.8%
SITE NOTES: 24 NOVEMBER 2021
1. ALL WORK TO BE CONSTRUCTED IN ACCORDANCE -
WITH THE CURRENT B.C.A INC. AMENDMENTS,
ALSO ANY RELEVANT AUSTRALIAN STANDARDS.
2. DRIVEWAY, PATHS CLOTHESLINE & GULLY PITS
ARE DIAGRAMMATIC ONLY. FOR SHAPE AND
LOCATION REFER TO BUILDERS SPEC FOR DETAILS.
3. SITE EXCAVATION SHALL BE SUCH THAT A 1M
WIDE BY 1:20 GRADE EXISTS AROUND THE
PERIMETER OF THE BUILDING AS PER THE
CURRENT B.C.A REQUIREMENT'S.
4. ALL DRIVEWAYS & PATHS ARE TO BE CONSTRUCTED
TO LOCAL AUTHORITY'S SATISFACTION AND RELEVANT 0°0'
BY-LAWS & AUSTRALIAN STANDARDS.
5. ALL GROUND LEVELS ARE APPROXIMATE ONLY.
6. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILS & SPECIFICATIONS SU
N
PRIOR TO SET-OUT AND ORDERING MATERIALS. PM
WI
NT
ER
ER
NT
SU
WI
BEAMS / LINTELS:
AM
MM
UN
SUN
ER
BEAMS / LINTELS HAVE NOT BEEN DESIGNED TO
PM S
W
SUMM
BREEZ ES PM
TAKE GIRDER TRUSSES. IF BEAMS ARE REQUIRED TO 270°0'
ER A M SU
E
W - SW
MER
TAKE GIRDER TRUSSES CONTACT AN ENGINEER FOR 90°0'
S UM
APPROPRIATE SIZES.
NDS
N
WI
MS
NE
OR
MAINS WATER PRESSURE:
ER
ST -S
ER
NT
E
I S UMM AM S
IF MAINS WATER PRESSURE EXCEEDS OR MAY W SU - SE
MM
ER
B RE EZ ES
EXCEED 500KPA, A PRESSURE LIMITING DEVICE IS
INSTALLED TO ENSURE THAT THE MAX OPERATING
PRESSURE AT ANY OUTLET WITHIN THE BOUNDARIES S
OF THE PROPERTY DOES NOT EXCEED 500KPA. 180°0'
STRUCTURAL:
1. STRUCTURAL TIMBER:
ALL STRUCTURAL TIMBER TO BE STRESS GRADE F14
UNLESS OTHERWISE NOTED.
ALL FRAMING TO COMPLY WITH AS 1684.2 85° 43' 30" 53440
2. STEEL WORK:
ALL EXPOSED STEEL TO BE PRIMED AND PAINTED.
ALL WELDS TO BE 6.0MM CONTINUOUS FILLETS.
348° 48' 40
INTERNAL LININGS:
1. 10MM PLASTERBOARD.
2. 6MM VILLABOARD TO WET AREAS.
IF IN DOUBT ASK!
" 7540
SURVEY SYMBOL LEGEND
1
180° 03' 00" 1395
NOOSA DRIVE
LIGHT POLE FENCE
ROCK RETAINING WALL
OP ORIGINAL PEG
TIMBER RETAINING WALL
TBM TEMPORARY BENCH MARK
S STORM WATER PIPE
POWER POLE
GAS SUPPLY
F
A
FIRE HYDRANT
AIR VALVE
G
BARRIER KERB LINE EXISTING UNIT
R
SEWER MANHOLE
ROOFWATER PIT S
SURVEY CONTROL MARK
STORMWATER MANHOLE 268° 29' 01" 14448 DEVELOPMENT
POWER BOX PERMANENT SURVEY MARK
TELSTRA PIT GULLY GRATE
CROSS-OVER WATER TAP/WATER/VALVE EXISTING UNIT 2
S
HEADWALL
SEWER LINE
SIGN (AS SHOWN)
4848
SW STORMWATER LINE
TOP Top of Bank
ELECTRIC POWER LINE
348° 48' 40 WALL
APPROX. TO
TOE Bottom of Bank
" 10149
APPROX. TO
2898
36090
258° 48' 40"
WALL
PROPOSED BEDROOM
EXTENSION
SITE PLAN
ISSUE DESCRIPTION DATE CLIENT DESIGN KJ CHECKED KJ
BUILDER A PRELIMINARY DRAWINGS 12.10.21 D. ALLEN
PROJECT
KIERON JAMES DESIGN UNIT 2 FLOOR AREAS
DRAWN
SCALE
KJ ISSUE
SHEET
A
BUILDING DESIGN & DRAFTING
PROPOSED ALTERATION/ADDITION MOBILE: 0417 633 275 1:200 A3 2 OF 10
EXISTING UNIT 2 92.6 m²
UNIT 2/33 P.O. BOX 483 COOLUM BEACH QLD 4573 TERRACE 39.1 m²
DWG NUMBER DATE
NOOSA DRIVE EMAIL: [email protected]
ALTERATION 8.4 m² 21-121 12.10.2021
Grand total 140.1 m² ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH
C COPYRIGHT THIS DRAWING REMAINS THE PROPERTY OF KIERON JAMES DESIGN & IS PROVIDED FOR THE USE AS DESCRIBED AND MAY
NOOSA HEADS MEMBER BDAQ : QBCC LICENCE No. 81726 THE BUILDING CODE OF AUSTRALIA and QUEENSLAND DEVELOPMENT CODE
NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. STANDARD BUILDING REGULATIONS and TIMBER FRAMING CODE AS 1684
Document Set ID: 21651747
Version: 1, Version Date: 19/10/2021
Page 3
EXISTING INTERNAL G.F.A. EXISTING EXTERNAL G.F.A.
LEVEL 1 INTERNAL GFA 87.0 m² LEVEL 2 EXTERNAL GFA 47.5 m²
LEVEL 2 INTERNAL GFA 92.6 m² LEVEL 3 EXTERNAL GFA 67.8 m²
LEVEL 3 INTERNAL GFA 169.3 m² LEVEL 4 EXTERNAL GFA 70.3 m² -
LEVEL 4 INTERNAL GFA 151.3 m² Grand total 185.6 m² APPROVED PLAN
51901.3961.01
Grand total 500.2 m²
4540 7060 2430
EXISTING SITE AREA - 715.32m² (FROM COUNCIL RECORDS) NOOSA COUNCIL
24 NOVEMBER 2021
EXISTING PLOT RATIO 500.2 / 715.32 - 0.70
230 1480 2830 150 6640 270 2160 270 -
PROPOSED INTERNAL G.F.A.
EXISTING INTERNAL G.F.A. 500.2 m²
ADDITIONAL G.F.A. 8.4 m²
230 4310 150 4650 4420 270
Grand total 508.6 m²
EXISTING SITE AREA - 715.32m² (FROM COUNCIL RECORDS)
PROPOSED PLOT RATIO 508.6 / 715.32 - 0.71
900H WALL TAPERED WALL FULL WALL
230
230
270
270
270
270
270
1220
950
820
270
EXISTING LIVING .
FFL 6173
26.52 SGD FSSFF
4680
EXISTING
5280
5280
5390
KITCHEN
3460
EXISTING BALUSTRADING TO 900H
.
TIMBER INFILL WALLS
UNIT 2 .
TILES
FFL 6516
EXISTING 400H WALL
EXISTING BALCONY
.
CARPORT.
FFL 6001
110 1000 110 110
110
10470
10010
10010
490
8290
EXISTING ROBE
110
110 1000 110
600
FUTURE ROBE EXISTING ROBE
TIMBER INFILL WALL
WM
4180
SLIDING GLASS DOOR EXIST. SPACE EXISTING BEDROOM .
BATH
BASIN TUB
- -
23.39 SGD SSF
26.39 SGD FSF
.
CARPET
4540
--- TILES FFL 6173 ---
3940
EXISTING BEDROOM
3430
3430
.
FLOOR LEVEL CARPET
E
WC
UIT
RAISED TO MATCH
FFL 6173
NS
INTERNAL FLOOR
270
E
RE
SHR
TU
12.18 SW
FU
960
960
9A
270
270
270
270
.0
230
230
06
900H WALL TAPERED WALL FULL WALL
PROPOSED BEDROOM
EXTENSION
2740 1800 150 4550 110 1090 110 3210 270
2740 90 1710 150 3840 110 1800 110 3210 270
230 1480 2830 5050 4440
4540 5050 4440
UNIT 2 PLAN
ISSUE DESCRIPTION DATE CLIENT DESIGN KJ CHECKED KJ
BUILDER A PRELIMINARY DRAWINGS 12.10.21 D. ALLEN
PROJECT
KIERON JAMES DESIGN UNIT 2 FLOOR AREAS
DRAWN
SCALE
KJ ISSUE
SHEET
A
BUILDING DESIGN & DRAFTING
PROPOSED ALTERATION/ADDITION MOBILE: 0417 633 275 1:100 A3 3 OF 10
EXISTING UNIT 2 92.6 m²
UNIT 2/33 P.O. BOX 483 COOLUM BEACH QLD 4573 TERRACE 39.1 m²
DWG NUMBER DATE
NOOSA DRIVE EMAIL: [email protected]
ALTERATION 8.4 m² 21-121 12.10.2021
Grand total 140.1 m² ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH
C COPYRIGHT THIS DRAWING REMAINS THE PROPERTY OF KIERON JAMES DESIGN & IS PROVIDED FOR THE USE AS DESCRIBED AND MAY
NOOSA HEADS MEMBER BDAQ : QBCC LICENCE No. 81726 THE BUILDING CODE OF AUSTRALIA and QUEENSLAND DEVELOPMENT CODE
NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. STANDARD BUILDING REGULATIONS and TIMBER FRAMING CODE AS 1684
Document Set ID: 21651747
Version: 1, Version Date: 19/10/2021
Used in these records
Approved Plan - 51901.3961.01.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type
No other editions are linked here.