  Lot 5 RP 227335
                                                                                                                                                                                                                                                                                      Notes:
  Site Area: 19981.16m²
  Local Authority: Noosa Shire                                                                                                                                                                                                                                                        #Landslide - High Hazard Area
  Council                                                                                                                                                                                                                                                                              Bushfire - Potential Impact Buffer

                                                                                                                                                     m
  Zone: Rural                                                                                                                                150.9                                                                                                                                    #Existing Powerbox may need upgrading
  Climate Zone: 2                                                                                                                                                                                                                                                                     to 3 Phase

                                                                                                                                                                                                                                                                                      #Powerlines run along Easement Parallel to
                                                                                                                                                                                                                                                                                      boundary.

                                                                                                                                                                                                                                                                                      #Overhead Powerlines - Okay from Power
                                                                                                                                                                                                                                                                                      pole to house.




                                                                                                                                                                                                                                                           124.
                     NORTH




                                                                                                                                                                                                                                                               72m
                                                                                                                                                                                                                                                                                      #Vegetation / Tree trimming Reguired
                                                        31.54m

                                                                                                                                                                                                                                                                                      down Property Access.

                                                                                                                                                                                                                                                                                      #PWD - Ramp Access to Cottage. May
                                                                                                                                                                                                                                                                                      need to be at angle to Cottage. Need to
                                                                                                                                                                                                                                                                                      Confirm with Clients is us to Install.

              Location of Existing Water Tanks
                                                                                                                                                                                                                                                                                      #No Level Access for Trucks or Crane.
                                                                                                                                                                                                                                                                                      - Machine work required for Crane
                                                                                                                                                                                                                                                                                      Access - Will do When Installing Drainage.

                                                                                                                                                                                                                                                                                      #1 Squat Water Tank 22500 Ltr - Refer to
                                                                                                                                                                                                                                                                                      Site Plan for approx. Location.
                                                              94.75
                                                                 m




                 Location of Existing Residence
                                                                                                                                                                                 STUDIO TO FACE 40 Deg
                 Location of Existing Meter Box -
                                                                                                                3600                                                             NORTH-EAST.
                 (35-40m)                                                               1000
                                                                                               0

                                                                                                                             13.3
                                                                                                   6m       14m                  m




                                                                                                                                                                                        1000
                                                                                           8000




                                                                                                                                                                                           Minim

                                                                                                                                                                                            0-S
                                                                                                                                                                  1030




                                                                                                                                                                                                e t ba c
                                                                                                                                                         To W




                                                                                                                                                                                                 um
                                                                                                                                                               0-S




                                                                                                       0                    ckk
                 Location of Existing Pool                                                         1560             Seettbbaac
                                                                                                               00 -- S
                                                                                                                                                                                                        k
                                                                                                                                                              all Fr




                                                                                                               6 0
                                                                                                           338450
                                                                                                                                                                  etbac




                                                                                                                                     16914                                                                     Location of Proposed 22500 Ltr
                                                                                                                                                                     ame




                                                                                                                                                                                                               Squat Water Tank. (approx.6m from
                                                                                                                                                                        k




                                                                                                                                                                                      0m
                                                                                                                                                                                162.3
                                                                                                                  1050




                                                                                                                                                                                                               Cottage). To be Confirmed Onsite.
                 Approx. Location of Crane Setup
                                                                                                                      0




                                                                                                                                                                         Location of Proposed Studio
                                                                                                                                                                                                                                         Overall Site Plan
                                                                                                                                                                                                                                         1 : 750
NOTE: THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE                                                                                                                                                                                                            Issue for Building Approval
ATTACHED BEARER, TRUSS & FRAMING DETAILS OF WHICH ALL DETAILS
AND CONSTRUCTION NOTES ARE REFERRED TO ENGINEERS DETAILS.




                                                                                                                                                                                                                                                                                                                                                6/06/2022 4:37:01 PM
All construction methods and
materials to comply with:                                                                  QBCC Licence No. 1151985
                                                                                                                                                                                                               Studio                       Revision Schedule                                         Site Plan              Revision number:
● The Building Act 1975                                                                    P: 07 5442 6888
                                                                                                                                                                                                                 for                        No.                 Description        Date   Project Status: BA                       9
● The National Construction Code                                                           M: 0400 737 595
● The Queensland Development Code                                                          E: [email protected]                                                                                       Sam Curatolo                    7      Issue for Site Visit          11-05-22
                                                                                                                                                                                                                                                                                                       GB Checked by:   GP   Sheet number:
● Building Regulations 2006                                                                www.ecocottages.com.au                                                                                                of                         8      Issue for Slope Stability &   19-05-22 Drawn by:
                                                                                                                                                                                                                                                   Engineering
● Relevant Australian Standards
● Local Government Planning Schemes
                                      DO NOT SCALE from these drawings.
                                      Figured dimensions take precedence at all times
                                                                                           © 2017 Eco Cottages Pty Ltd                                                                  528 Black Mountain Road, Black                      9      Issue for Building Approval   06-06-22   Scale:      As indicated @ A3      BA-02
                                                                                                                                                                                                  Mountain
Log in to download the original file

Attachment A - Proposal Plans.pdf · 4.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.