Engineering Plans · MCU16/0018
Attached to the e-mail MCU16/0018 - Response to Information Request.
Attached to the e-mail OPW16/0094 Application - 9 Duke Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
KE
EX. SWPT EXISTING STORMWATER PIT
RC. HW. REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
DRAWING SIZE - Al
HOUSE
NEIGHBOURING
GROUND LEVELS IN THIS AREA HAVE BEEN MODIFIED BY
BUILDING WORKS ON ADJOINING SITES AND DO NOT
ACCURATLEY REPRESENT THE NATURAL GROUND LEVELS -
THE CONTOURS SHOWN IN THIS AREA HAVE BEEN TAKEN
FROM THE NOOSA COUNCIL INTERACTIVE MAPPING WEBSITE.
RP-BOUNDARY
by Gp
% |
Cr oe |
S
lan On
o>) Cy © S x
3 "Gs S 29 G5
RP BOUNDARY
— _.__ f—— = SSF TF ITS
I f / a /
' / J & A
/ / / © x
| / / / ~
-f 4 / - Lot 204
i § / 7 (RP 48ITE
| s
| 3 8 < J
= i a EN ; . “
| /
é | ' SA / > /
Z, Ss ! / A C
DX» “©. & 1 oo on / / © /
ae & | 1s * / g :
6, & iB 8 f “ S
7 H / S
od | i / 8 & &
| | w .
| ; 8
| ! iS
| | 44.21
i I —
! Ss i on
| i 8 / a EXISTING TREES ON
/ 2 SITE TO BE REMOVED
| ; ~ Y AND ROOTS “GRUBBED
/ yas On
| f / 45.65
1 / %
| / Z 04 eg
i / a
—_— - — - — -: — S ss i Coa NZ De _ fo he Le I —2 Lo _ _
S = eZ oS o s = %
i Ss > % RPSBOUNDARY e %
> % Q cr 5 $ °
% %@ |
% 2
7 > |
&
NEIGHBOURING HOUSE
SITE PLAN — SITE SURVEY & EXISTING SERVICES
Scale 1: 100
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
www.dialbeforeyoudig.com.au
SA DIAL 1100
BEFORE YOU DIG
c€ Gr
ld Busia)
ov
9E°Sb
K&C
45.48
Power p
EX. SWMH EXISTING STORMWATER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&Cc EXISTING KERB & CHANNEL
.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
EXISTING KERBING
S
e
SW/EX SW/EX
SW/EX
SW/EX
Ex. SWMH
LEGEND
3.007
INDICATES EXISTING STORMWATER
DRAIN /MAIN.
SW/EX
INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF SITE FALL
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%. THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25%, LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
Checked:
RPEQ 5835
S Richardson
DO NOT SCALE FROM THIS DRAWING
SCG Consulting Engineers.
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
DESCRIPTION
AMEND DATE
APPR.
AMENDMENTS,
“FOR DEVELOPMENT APPROVAL
DEBUILD T/A
SCG)consulting ENGINEERS
STRUCTURAL eCIVILeGEOTECHNICAL
ABN 40 098 481 899
Ph (07) 5455 5604
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Fax (07) 5455 5696
Title:
OPERATIONAL WORKS:
SITE SURVEY & EXISTING SERVICES
Project
9 DUKE STREET
SUNSHINE BEACH
Scale:
Date: Warch 16 AS NOTED
Drawn:
Rev.
9 N°: 25464—OW1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 5 pages
Page 2
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWING SIZE - Al
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
NEIGHBOURING = HOUSE
ROLLER TO ACHIEVE A MINMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
x AB ; ~ THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
On o Qo 3 9, Xx CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
o o RP. BOUNDARY o Pp ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
= —. anos (PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
= SLF—- i) = 45.48 PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
° a Power ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
“T Pple - THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
ly
ev ov
9E'St
%,
P
be
|
|
S
oy
a
SSS SLES — — — SLE — — — SL — -
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%,
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
S BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
S ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
© FIELD DENSITY OF 95%.
i Oo — ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
=
I
1
i
/ PRIOR TO CONSTRUCTION COMMENCING.
/
i /
‘
i EN ) J
/ N / / _
y ny y / -
= _
'
7 /
Slot 2040 fons
5 / | / / RP4811 3 / J 44.45
é / J] .
/ / a s § / = \ 76
a
Ga
|
/ . / , s }
/ = / 45.84 44.70 |
J / |
\
a
|
p
/
I / )
SW/EX
~
co SV
NN
8ve'8
Beer —
RP-BOUNDARY
PO A
x
SW/EX
56.000
I
I
1
I
I
'
1
1
i
i
I
1
'
t
1
I
1
i
1
1
'
1
I
i
1
!
\
\
~7>>~-55,009-——_
54.000
rr Sh
£8 Sp
&
53.000
SW/EX
ol /
€S'p¢
/ A
Qo /
eo) / /
oO) c /
y 44, SO \
' 8 ( / 44.06 \ \
= / Jf \
‘ / CREATE asthinc IN
TEMPORARY HARDSTAND ‘~
/
;
( 44.21 FOR DIVERISION INTO
= SILT FENGES.
RP BOUNDARY
gel
9 6p
SL'Or
SW/EX
52.000
/ 45.65 /
/ %
44.04 %5
° a: 44, 6p Checked:
RPEQ 5835
S Richardson
! / / .
a - > _ S
Sy Ox S % RPSBOUNDARY & %, %
% Z D i Q C &
80-150mm ROCK (NO FINES)
HARD STAND OVERLAY
FOR DELIVERY'S DURING
CONSTRUCTION.
JOJO JOYEM
99' vv
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
SCG Consulting Engineers.
NEIGHBOURING HOUSE
SITE PLAN — SILT AND SEDIMENT CONTROL
Scale 1: 100
LEGEND
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
SILT RETENTION
THE CONTRACTOR IS TO INSTALL APPROVED SILT RETENTION FENCES
PRIOR 10 COMMENCING ANY EARTHWORKS. THE FENCE IS TO BE INDICATES EXISTING SURFACE AMEND | DATE
2.00 CONTOUR AND LEVEL TO AHD. SNENDWENTS
TO BE PROTECTED IN ACCORDANCE WITH THE
900(W) GEO-FABRIC SILT CONSTRUCTED ALONG THE LOWEST BOUNDARY AND RETURNED UP SIDE
Issue:
FOR DEVELOPMENT APPROVAL
APPR.
DESCRIPTION
AUTHORITY RESPONSIBLE FOR THE SERVICE
FENCE, FIXED TO SPIKES AND
* BOUNDARIES TO ENSURE FULL STORMWATER ENTRAPMENT. SURFACE
BURIED 300 INTO STABLE RUNOFF FROM WITHIN THE ALLOTMENT MUST DRAIN TOWARDS THE
— SIL-— — — — SILT RETENTION FENCE TO DETAIL
DEBUILD T/A
)
GROUND. S FENCE AND SHALL NOT ENTER NIEGHBOURING ALLOTMENTS THROUGH
THE USE OF SURFACE BUNDING OR SCOUR PROTECTED DRAINS. THE
FENCE MUST REMAIN IN PLACE UNTIL SUCH TIME THAT FINISHED
ae SCE) SOO ENGINEERS
LANDSCAPING AND DRAINAGE MEASURES ARE INSTALLED
i EXISTING SURFACE SPOT LEVELS. STRUCTURAL #CIVILeGEOTECHNICAL
ABN 40 098 481 899
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Fax (07) 5455 5696
INDICATES DIRECTION OF FALL UP
OR DOWN AS INDICATED Ph (07) 5455 5604
Title:
Sane) GREE LEVELS | OPERATIONAL WORKS:
GPT 00Sq GRATED FIELD INLETS, SITE SURVEY & EXISTING SERVICES
PRE-CAST CONCRETE.
DUST MOBILISATION FROM WIND ACTION
SITE CONTROL TO INCLUDE PROTECTION AGAINST THE
CARRIAGE OF SOIL SEDIMENT FROM WIND ACTIONS. SITE
FOREMAN TO COVER ALL STOCKPILES WITH HESION OR 1200(L) 50 SQ. HDWD SPIKES,
1800 CTRS DRIVE 600 INTO
SITE_DRAINAGE — CONSTRUCTION
ENSURE GROUND PROFILE DURING CONSTRUCTION FALLS SIMILIAR, PROVIDE SILT FENCING AROUND BASE OF to er
TOWARDS THE CENTRE OF THE ALLOTMENT THEN TOWARDS
THE FRONT BOUNDARY WHERE RUNOFF WILL DRAIN THROUGH STOCKPILES
THE SILT FENCES. IN NO INSTANCE SHALL THE ALLOTMENT
DRAIN INTO NEIGHBOURING ALLOTMENTS. MAINTENANCE OF SILT PROTECTION
SITE FOREMAN TO MAINTAIN ALL SILT AND SEDIMENT
Project
PROTECTION MEASURES THROUGHOUT THE DURATION OF
—— E——— ___ INDICATES OVERHEAD ELECTRICITY 9 DUKE STREET
www.dialbeforeyoudig.com.au
GE_DRAINAGE — CONSTRUCTION THE PROJECT. ANY BREACHING OF THE PROTECTION
MEASURES MUST BE REMEDIATED IMMEDIATELY AND SILT FENCE DETAIL
SUPPLY LINE
INDICATES EXISTING SEWER LINE SUNSHINE BEACH
CONSTRUCTED STORM WATER PITS WITHIN THE SITE ARE TO
DI AL BED What SLT BROTECHN WEASURES TO iE ari REPORTED TO THE ENGINEER FOR CORRECTION MEASURES.
Date: March 16 Scale: AS NOTED Drawn:
FALL
Bre EN SINEER ON MEASURES TO THE APPROVAL SILT RUNOFF PROTECTION IS TO BE MAINTAINED UNTIL
SUCH POINT THAT LANDSCAPING IS COMPLETED AND NOT
sw/ex_—_ INDICATES EXISTING STORMWATER
DRAIN /MAIN. BaNS. 95464 —0W9 Rew
BEFORE YOU DIG
SUSCEPTABLE TO STORMWATER SCOUR.
Page 3
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
DRAWING SIZE - Al
NEIGHBOURING HOUSE x
rc 1
[45,900 |
353.000)
~
SITE PLAN — DRIVEWAY ACCESS PLAN
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
WITH
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
ALL LINE MARKING TO BE IN ACCORDANCE
THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
SL82 MESH
MIDDLE
NOMINAL
KERB LINE
1000
25
lg
4
1 50MM
COMPACTED
SAW CUT AND
BREAKOUT SAND BED
BARRIER, SEMI-MOUNTABLE, MONTABLE
KERB & CHANNEL OR INVERT CROSSING
CROSSOVER DETAIL
(SCALE 1:20)
BACK OF KERB
/
UPPER LEVEL.
RL 49.000
NN
= Z
Lot 20 7 i
2 P4813 proposen PROPOSED UNIT |
eo RCPOSED DEVELOPMENT |
: RL_ 46,000 ¥
& = * |
/ » $5.84 » 44.70 UNIT 2, |
" / J / |
DRIVEWAY SLAB
40mm TOP COVER
125mm _ THK
SL82 MESH
(TJ) TOOLED JOINT DETAIL 50mm CLEAR ALONG LINE
WET TOOLED
INTROLLED FILL
LLLLL LL LS
MAI
CONTROL JOINT.
125mm
150(0) CONNOLLY
KEY JOINT PROFILE.
[Compacted Sub-Grade]
R16 DOWELS,
800 CRS. 125 THICK
SLAB.
ay
LOWER SLAB MESH TO
INTAIN 40mm TOP COVER
CUT EVERY SECOND WIRE
OF
190 BLOCK RETAINING WALL = s
a @ . “% e® a =E
A i = Ko?
a KE | @ 3S Q ir)
=
{ &
| ]
NEIGHBOURING — HOUSE
|.
&
|Z
a
le.
Cc > Cc
_O .00— = —<—— x 7 46.00 ©
—— + 2: . o> © aT Ww
DO 45.00 J <a x St 45.00 O
D490 44,99
Li GRATED! DRAIN —— Lu
BTM OF KERB
loo los lo lw Ino ko
EXISTING S.L. - + ~ z 8 = =
| Poy [3 3 wo || od Pook
~ “2 m S o to
PROPOSED LEVEL- J 8g 3 |
CUT/FILL — = & = 7 3 8
oO oS Oo oO Oo oO
CHAINAGE — g 5 z 5 8 5
DRIVEWAY PROFILE A
Scale 1: 200
JOIN
REQUIREMENTS
2.00
a
b
FALL
2.740
CE)
E
S/EX
CL ———
DRIVEWAY CROSSOVERS IN ACCORDANCE WITH
IPWEA STD DRG R-0050 AND COUNCIL
— STOP MESH SOMM
FROM JOINT.
KJ) DANLEY KEY JOINT DETAIL
i a
a 8
x O s &
2. 8
2
& 45.48
IN ov Power pble
a is
Z| ela =
(Ss ,
oot =
1 8ye
\ I x
\ te I, | S$
«(Ss oO 4
| siz
iS) 8 i
oi) No
g = | &
| o io
| fea] fF
/ ENSURE SMOOTH TRANSITION
uw |/ —— BETWEEN EXISTING FOOTPATH 10
§ NEW DRIVEWAY.
LEGEND
_-——_ INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL UP
OR DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS — PAVEMENT
INDICATES PROPOSED FINISHED
SURFACE LEVELS — LANDSCAPING
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES EXISTING STORMWATER
DRAIN /MAIN.
CONSTRUCTION NOTES.
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED 10 SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS 10 BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 10
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
Checked:
RPEQ 5835
S Richardson
4
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
‘SCG Consulting Engineers.
AMEND. DATE DESCRIPTION APPR.
AMENDMENTS
FOR DEVELOPMENT APPROVAL
DEBUILD T/A
&ce)<2r sulting ENGINEERS
STRUCTURAL eCIVILeGEOTECHNICAL
ABN 40 098 481 899
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Ph (07) 5455 5604 Fax (07) 5455 5696
Title:
OPERATIONAL WORKS:
DRIVEWAY & ACCESS
Project
9 DUKE STREET
SUNSHINE BEACH
Date: Scale: Drawn:
March 16 AS NOTED
Rev.
P9 No: 25464 —OW3 :
Page 4
Issue:
DEBUILD T/A
SCG ●CIVIL●GEOTECHNICAL
ABN 40 098 481 899
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Ph (07) 5455 5604 Fax (07) 5455 5696
Title:
Project
Date: Scale: Drawn:
Drg No.
Page 5
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
1.
1.73
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
DRAWING SIZE - Al
NEIGHBOURING HOUSE
INDICATES CONTIGUOUS CONCRETE PILING, DESIGN AND
INSTALLATION BY OTHERS. MINIMUM VIBRATION
X 25 | TECHNIQUES TO BE USED FOR INSTALLATION, VIBRATION
@, O CONTROL AND MANAGEMENT BY PILING CONTRACTOR. EXTENT OF PILES TO BE
%> | BUILDER TO CONFIRM EXTENT REQUIRED TO SATISFY
DETERMINED IN ACCORDANCE WITH
CRITICAL DEPTH LINE PROTECTION
CRITICAL DEPTH LINE PROTECTION OF NEIGHBOURING
STRUCTURES. REFER DETAIL.
HATCHING INDICATES 40° BATTERED g
BANK WITH CONCRETE SPRAYED Oe
FACE. REFER DETAIL BELOW.
% &
S
29'Sp_
as ———_ Es ———/S
lg Busia
evo"
9€°Sb
45.48
CONSTRUCTION NOTES.
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
Sb
ol Pp ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
oy Ower pbi
oa Sc e — THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
Yu AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
+~ KH E lu = CERTIFICATION WTH A MINIMUM RELATIVE FIELD DENSITY OF 95%
/ J \ a COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
L t 20 / 4A | | 5 CONSULTING ENGINEERS FOR APPROVAL.
O 0 / / x 44.50 | 3 & — FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
BASTING VESETATION 0 pp4attG / PROPOSED UNIT | 7 | & IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
1 , 4 | || 2 SPECIFCATIONS.
TO ENSURE SLOPE STABILITY. / PROPOSED _ DEVELOPMENT | a # v |) = — AREAS WHERE EXISTNG STRUCTURES OR TREES ARE REMOVED SHALL
L GARAGE. / / | | |S o BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
s / / | | 7 ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
3 s FPL 46.000 s | * Bl) 3 FIELD DENSITY OF 95%
x ‘ ev * & ° Tes — ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
8 / . 45.84 x 44.70 UNIT 2. | | ‘se 3 PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
A, © a» / | oo | > FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
a 7 <7 J | s i % ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%
8, / * — SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
25 / / PRIOR TO CONSTRUCTION COMMENCING.
ls
Checked:
ic s //90 BLOCK RETAINING WALL z | “9 S Richordeon
HATCHING INDICATES CUT BENCH o Q s 28 Rg) ot
AT R.L. 48.800. a | 5 ee ue Sos
% % | 2 eB
2 a eo &
% o
or, | | 8 e
° SITE PLAN — SITE BENCHING & RETAINING WALLS 7
| Scale 1: 100 | rm"
fnanai——1_}—1_7m1:100 @ Al
| | 1:200 @ A3
DO NOT SCALE FROM THIS DRAWING
The design ‘and associated details contained on this ‘ond associated drawings are
EXISTING STRUCTURE /DWELLING NEIGHBOURING HOUSE Se retag trgneet used or reproduced without the written permission of
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER /CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR TO
COMMENCING WORKS.
Ground / GROUND LEVEL
pad level LEGEND AMEND DATE DESCRIPTION APPR.
UNSTABLE AMENDMENTS
&» ] ieee i POGNAED 90 INDICATES EXISTING SURFACE Tssue
THIS FOOTING IS FOUNDED ABOVE CRITICAL DEPTH 2: CONTOUR AND LEVEL TO AHD. FOR DEVELOPMENT APPROVAL
BELOW CRITICAL DEPTH LINE AND IS UNSTABLE. FAONG S72 MESH MODLE a DeBULDTA
LINE AND IS STABLE. STABLE * EXISTING SURFACE SPOT LEVELS. ce): onsulting ENGINEERS
STRUCTURAL eCIVILeGEOTECHNICAL
ABN 40 098 481 899
LINE OF PROPOSED FALL, — INDICATES DIRECTION OF FALL UP
OR DOWN AS INDICATED 1/11 PROJECT AVE, NOOSAVILLE QLD 4566
PIERS OR UNDERPINNING FOUNDED 1.73 aril OR OTHER Ph (07) 5455 5604 Fax (07) 5455 5696
WOULD BE NESDED 10 SUPPORT NX , EXCAVATED LEVEL Hoare eR tose er D Tie:
i FQTNG THA DINE senoge wera NX SNES stows mores masicn [OPERATIONAL WORKS:
ABOVE THE CRITICAL DEPTH LINE. i TT
Horizontal 30 Degrees —_ WORKS COMMENCING. [2.740 | SURFACE LENELS TANDSCAPING SITE BENCHING & RETAINING WALLS
NOTE: Project
CRITICAL DEPTH LINE THIS DETAIL ALSO APPLIES 70 EXISTING E INDICATES OVERHEAD ELECTRICITY rojec
FOUNDATIONS ON NEIGHBOURING 9 DUKE STREET
PROPERTIES. SHEET PILING MUST BE S/EX INDICATES EXISTING SEWER LINE SUNSHINE BEACH
OE Ne roam WILL TYPICAL SECTION ~ SPRAYED CONCRETE FACED EMBANKMENT
sw/EX ——————__ INDICATES EXISTING STORMWATER Date: le: D :
CRITICAL DEPTH LINE / DRAIN /MAIN. te Mare 16 | °°" as noteD | O"*"
Pra N° 95464 —-OW5 Rev.
Page 6
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
DRAWING SIZE - Al
www.dialbeforeyoudig.com.au
De
DIAL1100
BEFORE YOU DIG
NEIGHBOURING
CONSTRUCTION NOTES.
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
’ ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
- “3 | ALL UPPER LEVEL ROOF b a BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
8,0 | DRAINAGE TO PASS THROUGH 5.2 FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
%> SW-IP INFILTRATION PITS y o & & COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
=> Ss ww ENGINEERS FOR APPROVAL.
| Oo ° — THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
: CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
b ___|_ APPROVED KERB ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
eee EE nnn’ ay ADAPTORS (PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
| wan OC |A45.4 8 PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
t B P ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
3/ Ie ube iy ower Dble — THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
{3 a AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
See ee — — 8 wv = uy = CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
/ / a/ / | \ a a COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
=lot 20 f «44.50 | i CTFLLNG AND COMPACTING ADIAGENT EXSTING STRUCTURES 1610 BE
/ 2 RP4811 3 / / / | a4 \ 8 8 IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
= " / 4, \ tok is SPECIFCATIONS.
/ / S / / / | | oO # To S, = — AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
/ ao / / / | \ j2$ o BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
I / ee / | \ & 7 5 ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
B aS. ‘kt FIELD DENSITY OF 95%.
a“ & & | — ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
| £ | zs PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
A, © | oo ! > FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
a 7 Ti / ” ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
o, * FOX BPT600 GROSS — SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
<) POLLUTANT TRAP. PRIOR TO CONSTRUCTION COMMENCING.
w 7 DRAIN GRATED DRAIN
OVER FOX PIT,
s REFER DETAIL.
Checked:
Se s ; x a RPEQ 5835
) S So e XB S Richard
& S % s 5 %, z y =e & ichardson
© 7 $ Dy i > 9 & ROD wa
Le %p | o (28S (| BB LEGEND
>
Xp = eo & __-——_ INDICATES EXISTING SURFACE
"x5 | ; 8 2 CONTOUR AND LEVEL TO AHD.
| SITE PLAN — STORMWATER MANAGMENT | —sut— SILT RETENTION FENCE TO DETAIL oO 12 8 Sag @ At
| Scale 1: 100 | uu WH UW 1:200 © AZ
CONTRACTOR TO LOCATE ALL SERVICES PRIOR 10 THIS PLAN TO BE READ IN CONJUNCTION WITH ' EXISTING SURFACE SPOT LEVELS. DO NOT SCALE FROM THIS DRAWING
COMMENCING WORKS ON SITE. ALL SERVICES ARE SCG CONSULTING ENGINEERS STORMWATER NDCATES DIRECTION OF Ramp up | Ripe tl cin io wa evi
TO BE PROTECTED IN ACCORDANCE WITH THE MANAGEMENT REPORT 26069SWM. ight and are not to be used or reproduced without the written permission of
AUTHORITY RESPONSIBLE FOR THE SERVICE ) NEIGHBOURING HOUSE AMP OP DOWN AS INDICATED SCE Conslting Engines em
[27H] _INDICATES PROPOSED FINISHED
SURFACE LEVELS
GP1
450Sq GRATED FIELD INLETS,
AUSDRAIN ENVIROMODULE 2 PROVIDE INSPECTION OPENINGS PRE-CAST CONCRETE, HEAVY DUT
INFILTRATION CELLS 5 IN LINE (.0.S) FROM SLOTTED PIPE IN RAINEALL GRATE WHERE IN DRIVEWAYS.
STACKED 2 HIGH, WRAPPED IN BASE FOR FLUSH OUT INFAL
GEOFABRIC STORMWATER RUNOFF ASSESMENT 180(¥) GRATE GP2 450Sq STORMWATER JUNCTION
DESIGN STORM INTERVAL 100 YEAR ARI STONE RUBBLE TO [><] 80x, PRE-CAST CONCRETE. AND
LOS 10S SITE TIME OF CONCENTRATION 5 Min. DIRECT RUN OFF SEALED LID AMEND | DATE DESCRIPTION APPR.
VU. wv 100_YEAR ARI COEFFICIENTS OF RUNOFF INTO FOX TRAP.
F al a PERMEABLE AREA — 0.84 or AMENDMENTS
STORMWATER poo ttaa ne - - - - - +=—4 IMPERMEABLE AREA ~ 1.0 ES FOX BPT600 GROSS POLLUTANT _ |Issue:
INFLOW FROM ROOF UNS oA ROOF RUNOFF oRvEWaAy — TRAP. DRAIN GRATED DRAIN over | __ OR DEVELOPMENT APPROVAL
ONLY NALTRATON PTS busts a SES FOX PIT, REFER DETAIL. DEBULD TIA
100 - 51 It/s 6ce .
—TREAT FIRST FLUSH RUNOFF FROM ROOF’S Lt FOX TRA OPOO) © SW-IP 32(No.) AUSDRAIN SOG acrana cu dearnomuna.
! | STORAGE AND ONGOING INFILTRATION PROPOSED SITE FOX TRAP (BCPCT) DETAIL DXB] ~—- ENVIROMODULE 2 INFILTRATION ABN 40 098 481 899
PROVIDE DROPS AT EACH END | | XxX _| | XI REDUCES DEVELOPED SITE RUNOFF Qiqo ~ 57 It/s TANKS 6 IN LINE STACKED 2 | 4/44 PROJECT AVE, NOOSAVILLE QLD 4566
OF THE PIT FROM THE MAIN te — “Sh i — SH | INFILTRATION PITS ‘)GPT= GROSS POLLUTANT TRAP HIGH x 2 WIDE. REFER DETAIL. | Ph (07) 5455 5604 __Fax (07) 5455 5696
u J INCREASED RUNOFF OF 6 L/s OVER A 5 MINUTE
THROUGH DRAIN TO THE GPT “CapreRee NOROCAREGNS STORM CAPTURED BY SOAKACE PIT AND E INDICATES OVERHEAD ELECTRICITY Title:
SLOTTED PIPE IN THE BASE ~e Wy DISPOSED OF VIA INFILTRATION. SUPPLY LINE OPERATIONAL WORKS:
—— PROVIDE SLOTTED PIPE eC S INDICATES EXISTING SEWER LINE :
ALL PIPE PENETRATIONS THROUGH THE GEOFABRIC 10 THROUGH BOTTOM OF TO GROUNDWATER STORMWATER MANAGEMENT
BE FITTED WITH STAINLESS STEEL PIPE CLAMPS, CELLS T INDICATES TELSTRA LINE APPROX Prol
GEOFABRIC TO BE LAPPED AT JOINS WITH A ROOT RrnerRucTate ALIGNMENT, BUILDER TO CONFIRM roject
INHIBITOR PROVIDED ALONG THE JOIN LINES EXACT LOCATION PRIOR TO woRKS} 9 DUKE STREET
AUSDRAIN INFILTRATION SOAKER PIT DETAIL WATER CYCLE DIAGRAMATIC oy WOIATES STORUWATERORAN SUNSHINE BEACH
ED OR EXISTING AS NOTED |Daie- Scale: Drawn:
MIN 1 IN 100 FALL UNLESS NOTED |-- March 16 | ~~~ AS NOTED |
OTHERWISE Drg No. Rev.
Ne. 5464 —SW "