Council archive · source document
Engineering Plans · MCU16/0018
Attached to the e-mail MCU16/0018 - Response to Information Request.
Attached to the e-mail OPW16/0094 Application - 9 Duke Street Sunshine Beach.
Plans and drawings: the text below has words only, no drawings.
ABN 40 098 481 899
DEBUILD T/A
Fax (07) 5455 5696
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Drawn:
●CIVIL●GEOTECHNICAL
Scale:
Ph (07) 5455 5604
Project
SCG
Title:
Drg No.
Issue:
Date:
le
Power po
Scr 2
ew
44.6
45.48
0 2
.1 .7
45 44 8
45.36 44.3
45.22 44.86 44.87 3
45.4
9 44.4
Telstra P 45.55
it Concrete Footpath 44.57
45.33 44.93 44.64
45.62
45.44 140°0' 44.66
Water Meter
133°0'
6 6.789 44.64
.8
45 8.348
.8
3 45.29
45
6
0
45.0
.8
.16
44 63
45
44.
44.93
.87
44 1
44.6
. 88
44
44.42
0
44.3
6
.2
44
44.50
44.06
9
.4
44.04
45 9
44.21
.1
44
79
44.70
.
45
45.0
45.84
9
4
44.6
47.4
1
45.7
2
45.65
46.15
48 45.45
.67
47.0 46
8 .82
48.36
27
48.
49.36
6
.9
50
0 51.36
52.5 04
51.
.41
52
54.53
8
.9
54
.93
56.70 55
2
0 18 113
18 113 48
48 RP
RP 1 3
18 11
48
RP
[OCR of page images]
DRAWING SIZE - Al
NEIGHBOURING HOUSE x
rc 1
[45,900 |
353.000)
~
SITE PLAN — DRIVEWAY ACCESS PLAN
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
WITH
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
ALL LINE MARKING TO BE IN ACCORDANCE
THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
SL82 MESH
MIDDLE
NOMINAL
KERB LINE
1000
25
lg
4
1 50MM
COMPACTED
SAW CUT AND
BREAKOUT SAND BED
BARRIER, SEMI-MOUNTABLE, MONTABLE
KERB & CHANNEL OR INVERT CROSSING
CROSSOVER DETAIL
(SCALE 1:20)
BACK OF KERB
/
UPPER LEVEL.
RL 49.000
NN
= Z
Lot 20 7 i
2 P4813 proposen PROPOSED UNIT |
eo RCPOSED DEVELOPMENT |
: RL_ 46,000 ¥
& = * |
/ » $5.84 » 44.70 UNIT 2, |
" / J / |
DRIVEWAY SLAB
40mm TOP COVER
125mm _ THK
SL82 MESH
(TJ) TOOLED JOINT DETAIL 50mm CLEAR ALONG LINE
WET TOOLED
INTROLLED FILL
LLLLL LL LS
MAI
CONTROL JOINT.
125mm
150(0) CONNOLLY
KEY JOINT PROFILE.
[Compacted Sub-Grade]
R16 DOWELS,
800 CRS. 125 THICK
SLAB.
ay
LOWER SLAB MESH TO
INTAIN 40mm TOP COVER
CUT EVERY SECOND WIRE
OF
190 BLOCK RETAINING WALL = s
a @ . “% e® a =E
A i = Ko?
a KE | @ 3S Q ir)
=
{ &
| ]
NEIGHBOURING — HOUSE
|.
&
|Z
a
le.
Cc > Cc
_O .00— = —<—— x 7 46.00 ©
—— + 2: . o> © aT Ww
DO 45.00 J <a x St 45.00 O
D490 44,99
Li GRATED! DRAIN —— Lu
BTM OF KERB
loo los lo lw Ino ko
EXISTING S.L. - + ~ z 8 = =
| Poy [3 3 wo || od Pook
~ “2 m S o to
PROPOSED LEVEL- J 8g 3 |
CUT/FILL — = & = 7 3 8
oO oS Oo oO Oo oO
CHAINAGE — g 5 z 5 8 5
DRIVEWAY PROFILE A
Scale 1: 200
JOIN
REQUIREMENTS
2.00
a
b
FALL
2.740
CE)
E
S/EX
CL ———
DRIVEWAY CROSSOVERS IN ACCORDANCE WITH
IPWEA STD DRG R-0050 AND COUNCIL
— STOP MESH SOMM
FROM JOINT.
KJ) DANLEY KEY JOINT DETAIL
i a
a 8
x O s &
2. 8
2
& 45.48
IN ov Power pble
a is
Z| ela =
(Ss ,
oot =
1 8ye
\ I x
\ te I, | S$
«(Ss oO 4
| siz
iS) 8 i
oi) No
g = | &
| o io
| fea] fF
/ ENSURE SMOOTH TRANSITION
uw |/ —— BETWEEN EXISTING FOOTPATH 10
§ NEW DRIVEWAY.
LEGEND
_-——_ INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DIRECTION OF FALL UP
OR DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS — PAVEMENT
INDICATES PROPOSED FINISHED
SURFACE LEVELS — LANDSCAPING
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES EXISTING STORMWATER
DRAIN /MAIN.
CONSTRUCTION NOTES.
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25% LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED 10 SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS 10 BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 10
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
Checked:
RPEQ 5835
S Richardson
4
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
‘SCG Consulting Engineers.
AMEND. DATE DESCRIPTION APPR.
AMENDMENTS
FOR DEVELOPMENT APPROVAL
DEBUILD T/A
&ce)<2r sulting ENGINEERS
STRUCTURAL eCIVILeGEOTECHNICAL
ABN 40 098 481 899
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Ph (07) 5455 5604 Fax (07) 5455 5696
Title:
OPERATIONAL WORKS:
DRIVEWAY & ACCESS
Project
9 DUKE STREET
SUNSHINE BEACH
Date: Scale: Drawn:
March 16 AS NOTED
Rev.
P9 No: 25464 —OW3 :
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Engineering Plans.pdfRelated documentApplication case desk ↗
SCG_25464-OW1-SW1_23.03.2016-1.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (small file)
- File type
No other editions are linked here.