Bushfire Hazard Assessment

of 34

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                           BHA Report for36 Riverpark Drive, Ringtail Creek




APPENDIX 1


POTENTIAL BUSHFIRE ATTACK LEVEL

The Australian Standard, Construction of Buildings in Bushfire Prone Areas (AS 3959-2018) provides a suitable methodology
for identifying assessable vegetation and determining the requirements for the construction of buildings in order to improve
their resistance to bushfire attack from burning embers, radiant heat, flame contact and a combination of the three attack forms.



Method for Determination of BAL

The BAL was determined in accordance with Appendix B of AS 3959-2018, Detailed Method for Determining the Bushfire
Attack Level (BAL) – Method 2 (Normative):
Step 1: Determine the relevant FDI.
Step 2: Determine the vegetation classification, fuel loads.
Step 3: Determine the effective slope in degrees under the classified vegetation.
Step 4: Determine the slope in degrees of the land between the site and the classified vegetation.
Step 5: Determine the distance of the site from classified vegetation.
Step 6: Calculations.



Determination of BAL

Step 1. Relevant Fire Danger Index
The PSBA bushfire hazard mapping identifies the FFDI as 47.
Step 2. Vegetation Classification - Fuel Loads
The vegetation type was classified as Remnant RE 12.3.2 - Wet eucalypt tall open forest and RE 12.3.4 Melaleuca open forests
on seasonally inundated lowland coastal swamps. Available fuel weights were derived from PSBA State – Wide Bushfire
Hazard (Bushfire Prone Area) Mapping. Fuel weight was determined as: 35 tonne/hectare.
Fuel weights were determined as:
    •    28.0 tonne/hectare surface fuels
    •    3.0 tonne/hectare near surface fuels
    •    3.0 tonne/hectare elevated fuels
    •    2.0 tonne/hectare bark fuels
    •    Total fuel weight = 35 tonne/hectare.

+ Bushfire assessments
+ Property vegetation assessments
+ Site planning for bushfire
+ Property management for bushfire                                                  Bushfire Planning Specalists - qldbushfireplanning.com.au
+ Bushfire management plans
Log in to download the original file

Bushfire Hazard Assessment.pdf · 1.5 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.