Council archive · source document
Att 1 - Revised Building Design Plans · MCU24/0001
Plans and drawings: the text below has words only, no drawings.
Very large file (19.7 MB): may take a few minutes to open.
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
Colorbond slotted gutter, fascia to match
roofing. Fix to manufacturers specification. Aluminum framed windows
(Nom. 150 Skyline Gutter) to manufacturers specification.
FC Sheet cladding with cover battens
to manufacturers specification
MS1 - Colorbond Custom Orb roof sheeting LINE OF 8.0M BUILDING
fixed to manufacturers specification ENVELOPE FROM EXISTING NGL.
for required wind category. (25° pitch). Timber pergola structure
to engineers specification
Planter box to engineers
specification
Timber pergola structure
to engineers specification
Timber framed balustrade
North EC1 - Scyon Easylap cladding to engineers specification
Proposed exposed aggregate driveway Timber framed property fence
Scale : 1 : 100 with 50% transparency
MS1 - Colorbond Custom Orb roof sheeting Hardies Fine Texture Cladding
fixed to manufacturers specification with painted finish
for required wind category. (25° pitch).
Colorbond slotted gutter, fascia to match
C:\Users\phil\qldBUILT Dropbox\qldBUILT Design (phil)\2 Jan St\1-PRE CON\3 - Architectural Design\8 - Revit Files\2 Jan Street - Working Drawings rev_A.rvt
roofing. Fix to manufacturers specification. LINE OF 8.0M BUILDING
(Nom. 150 Skyline Gutter) ENVELOPE FROM EXISTING NGL.
CL
JL Aluminum framed windows
to manufacturers specification.
2700
2400
Timber pergola structure
Feature recycled brick to engineers specification
to boundary walls as specified
Scyon Lineaboard Cladding
FL
2400 Top of Beam
CL
JL Feature recycled brick
1390
to boundary walls as specified
1545
2700
2400
2000 Pergola Width
FL Planter box to engineers
West specification
Scale : 1 : 100
The drawing and the design depicted on this sheet remains the property of qldBUILT. Reproduction in part or whole is prohibited
C COPYRIGHT unless written permission is obtained from qldBUILT. Plans are designed for use on the job address specified in the titleblock only.
DIRECTOR : DESIGN TEAM : PROJECT ADDRESS : PROJECT REVISION SCHEDULE DATE : 21/02/24 A3
Aaron Waters STATUS: Developed Drawings - C Number Description Date Issued by
Dominic Tyacke
E : [email protected] E : [email protected] 2 Jan Street 7 Client revisions 07/02 08/02/24 PD
PROJECT NUMBER: SHEET NUMBER:
M : 0410 332 167 CLIENT : 8 Council RFI 21/02/24 PD
Q.B.C.C LICENCE NO. : 15035880 QLDBUILT PTY LTD
W: www.qldbuilt.com.au
Phil Darwen
E : [email protected]
Noosa Heads Venter, Greg & Keri amendments
23-007 07
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 1 - Revised Building Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 19.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.