                                                                                                                                                                                                               BRACING NOTES
                                                                                                                                                                                                               B1    BRACING TYPE (h) METHOD 'B' AS PER
                                                                                                                                                                                                                     "A.S.1684.2-2010" TABLE 8.18 AT 6kN/m FOR MIN.
                                                                                                                                                                                                                     900mm LENGTH. BRACING TO BE INSTALLED IN
                                                                                                                                                                                                                     ACCORDANCE WITH MANUFACTURERS SPECIFICATION TO
                                                                                                                                                                                                                     ACHIEVE 6kN/m.
                                                                                                                                                                                                               B2    FOR LESS THAN 900mm LENGTH PROVIDE M12 ANCHOR
                                                                                                                                                                                                                     RODS AT EACH END OF PLY BRACING WALL.
                                                                                                                                                                                                               B3    FOR WALLS SHEETED ON BOTH SIDES, PROVIDE M12
                                                                                                                                                                                                                     ANCHOR RODS AT EACH END OF PLY BRACING WALL.




                                                                                                                                                                                       900 PLY
                                                                                                                                                                                                               B4    BRACING WALLS ARE TO BE CONNECTED TO THE ROOF
                                                                                                                                                                                                                     FRAMING OR TO THE CEILING OR TO THE EXTERNAL




                                                                                                                                                                                                                       N
                                                                                                                                   900 PLY                                                                           WALL FRAME IN ACCORDANCE WITH "A.S.1684.2-2010".




                                                                                                                                         900 PLY
                                                                                                                                                                                                                     THE CONNECTION IS TO BE OF EQUAL STRENGTH TO THE
                                                                                                                                                                                                                     BRACING STRENGTH THAT IS REQUIRED BY THE




                                                                                                                                                                                                                     O
                                                                                                                                                                                                                     BRACING WALL.




                                                                                                                                                                                                             I
                                                                                                                                                                                                               B5    FOR WALLS HIGHER THAN 2700mm A HEIGHT REDUCTION
                                                                                                                                                                                                                     FACTOR HAS BEEN APPLIED IN ACCORDANCE WITH
                                                                                                                                                                                                                     "A.S.1684.2-2010".




                                                                                                                                                                                                    C      T        900 PLY
                                                                                                                                                                                                                                   LEGEND




                                                                                                                                                                                        900 PLY
                                                                                                                                                      900 PLY
                                                                                                                                                                                                                                INDICATES PLY BRACE WALL BELOW
                                                                        900 PLY                  900 PLY                                                        900 PLY      900 PLY




                                                                                                                                                                                                  U
                                                                                                                                                            900 PLY          900 PLY
                                                                                   900 PLY
                                           900 PLY
                               900 PLY




                                                              900 PLY




                                                                                                                  900 PLY
                                                                                                                                      R

                                                                                                                                         900 PLY
                                                                                                                                   ST
                                                                                                                                 N
                               900 PLY




                                                                                                                                O
                                                                         900 PLY




                                                                                                      900 PLY




                                                                                                                              C
                                         900 PLY           900 PLY                                              900 PLY




                                                              O R
                                                         WALL BRACING PLAN

                                                             F
                                                         SCALE 1:100




                                                           T
                               N O
DO NOT SCALE FROM DRAWING
ALL SCALES ARE AS SHOWN (A3)

REV.            DESCRIPTION     DATE             INIT.                                       CONTACT DETAILS                  CLIENT                               PROJECT                         TITLE                              DRAWN         DESIGNED   DATE

  A    PRELIMINARY ISSUE       22.08.22 C.Y.                                                 EMAIL       [email protected]
                                                                                                                                                                                                                                          C.Y.         C.Y.    AUG 2022
                                                                                             WEB         www.peerce.com.au                                                                                                            CHECKED       APPROVED
  B    PRELIMINARY ISSUE       29.08.22 C.Y.
                                                                                                                                                                  PROPOSED NEW DWELLING                                                   N.Z.
                                                                                             MOBILE      0425 885 440
                                                                                                                                       LEIF O'BRIEN                                                    WALL BRACING PLAN
                                                                                             POST        PO BOX 5296                                                56 RESERVE STREET,                                                DRAWING No.                     REV.
                                                                                                         ALGESTER, QLD 4115
                                                                                                                                                                     POMONA QLD 4568                                                   PCE2211 - S08                    B
Log in to download the original file

Enginerring plans RESERVE STREET NEW RESIDENCE REV B.pdf · 316 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.