Original source · versioned page text
2401 DA05 19062024
Very large file (15.7 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 3, section 2. The text section number identifies this passage in the reader.
in system with sponge finish and painted.
fe n
accordance with local authority regulations. Driveway grades to be in accordance fe n
ce
Concrete block walls to form lift shaft to be in accordance
fence type 1
with AS2890.1. Driveway to be have clear slip resistant clear penetrating sealer to ty p
e3
entire driveway, applied in accordance with manufacturers specifications. with structural engineers design and detail. Lift shaft to suit
wall
e 6m
ck lin s et
etba Lift ECOTRAK Series 3 by Easy Living Elevators (1C8)
6,39tback
6m s bac
6,244
6,244
Flow Defence Passive flood barrier to be installed in accordance with manufacturers k lin
se
e
Formed concrete stairs to be in accordance with structural
8
specifications.
ck
engineers design and detail. Stairs to be in accordance with
a
etb
wa 021
Flood gate ABCB Housing Provisions Standard 2022 : 11.2 Stairs to
e1
ll s
ty p
have cantilevered treads with selected tile facings.
FF 6,
750
ce
fe n
62
6,1
D D
G01
600mm dia. Concrete pavers in exposed aggregate blend to
manufacturers specifications to match driveway. Pavers to be
Garden
Garden have clear slip resistant clear penetrating sealer, applied in
A accordance with manufacturers specifications. A
wall
Planter wall
3,39tback
3,
94
se
Knotwood (Light Oak) battens to form sliding gate panels. Battens to be 25 x 25mm 0
0
sections (15mm gap) to be fixed in accordance with manufacturers specifications.
Exposed Agg.
Bin store
Driveway
Concrete driveway to be in accordance structural engineers design and detail. Exposed Agg. New 2.0m high concrete block wall to be in accordance with
95
Provide selected exposed aggregate blend to manufacturers specifications. 0 structural engineers design and detail. Wall to be finished
wall
Driveway to comply with AS2890.1. Driveway to connect to existing crossover in 7 with acrylic render system with sponge finish and painted.
200 back
accordance with local authority regulations. Driveway grades to be in accordance
set
with AS2890.1. Driveway to be have clear slip resistant clear penetrating sealer to
entire driveway, applied in accordance with manufacturers specifications. 5 6 Concrete block retaining walls to be in accordance with
structural engineers design and detail. Provide upvc drainage
outlets and Emer-Proof Landscape waterproofing system with
VersiDrain® 60, geofabric and premium soil fill and plants to
landscapers specifications.
950 3,750 2,030
H
1 2 3 4
600mm dia. Concrete pavers in exposed aggregate blend to
Floor plan - Ground floor manufacturers specifications to match driveway. Pavers to be
1:100 A B C have clear slip resistant clear penetrating sealer, applied in
accordance with manufacturers specifications.
/Users/benthornton/Documents/Cadfiles/2401 - Palazzesi/Archicad/
19062024/2401.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 145 DA05 Development applicaiton issue 19/6/2024
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. N21859 DA04 Develoment application issue 23/4/2024
2401
skale
DA03 Develoment application issue 14/4/2024
skale.com.au 38 Mossman Court drawn BT
DA02 Develoment application issue 5/3/2024
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa Sound scale (A2) 1:100 Rev Details Date 03 DA05 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.