Original source · versioned page text
2401 DA05 19062024
Very large file (15.7 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
¿ play your part - print on recycled paper 5m 4 3 2 1
E D C B A Suspended concrete roof to be in accordance with structural engineers
design and detail. Provide fall to rwo's. Roof to have upvc drainage
Concrete block wall to be in accordance with structural engineers design
and detail. Wall to be finished with acrylic render system with sponge outlets and EmerProof waterproofing system. Exposed surfaces fascia &
3,600 10,946 2,000 6,244 soffit to have acrylic render system in accordance with manufacturers
finish and painted.
Cantilevered glass pool fence to be in accordance with the Building Act specifications.
1993, Building Regulation 2006, AS 1926 . Pool fence min. 1200mm
high above adjoining finished surface level and have non climbing zone
as specified in pool legislation. Glass panels with rebated channel with
Knotwood (Light Oak) battens to form fence. Battens to be 150 x 25mm
non- shrink structural grout. 9,550
sections (300mm spacing typical) to have concealed fixings in
9,200 accordance with manufacturers specifications.
Ceiling
Concrete block retaining wall to be in accordance with structural
3,000
engineers design and detail. Provide EmerProof water proofing barrier to
wall with root barrier guard and 100mm sleeved ag. drain, free draining
back fill.
6,200
First floor
5,600
Concrete block with green roof to be in accordance with structural
engineers design and detail. Roof to have upvc drainage outlets and
EmerProof Landscape waterproofing system with premium soil fill and
4,425 4,495
3,500
plants to landscapers specifications.
4,200
3,825
3,469
Existing jetty unchanged. Concrete driveway to be in accordance structural engineers design and
detail. Provide selected exposed aggregate blend to manufacturers
specifications. Driveway to comply with AS2890.1. Driveway to connect
2,700 to existing crossover in accordance with local authority regulations.
Ground floor Driveway grades to be in accordance with AS2890.1. Driveway to be
have clear slip resistant clear penetrating sealer to entire driveway,
applied in accordance with manufacturers specifications.
4,990
3,200
Formed concrete roof (green roof) to be in accordance with structural
engineers design and detail. Roof to have upvc drainage outlets and
EmerProof Landscape waterproofing system with premium soil fill and
plants to landscapers specifications.
-500
Basement
Concrete block wall to be in accordance with structural engineers design
Suspended concrete terrace to be in accordance with structural
and detail. Wall to be finished with acrylic render system with sponge
engineers design and detail. Provide fall to outside line of building.
finish and painted. Wall on boundary to achieve min. 60/60/60 FRL.
Provide EmerProof waterproofing system. Exposed surfaces fascia &
soffit to have acrylic render system in accordance with manufacturers E D C B A
specifications. Provide selected slip resistance tiles to be installed in
accordance with final colour selections.
North Eastern Elevation
NE 1:100
Suspended concrete roof to be in accordance with structural engineers
Formed concrete roof beams to be in accordance with structural 4 3 2 1 design and detail. Provide fall to rwo's. Roof to have upvc drainage
outlets and EmerProof waterproofing system. Exposed surfaces fascia &
engineers design and detail. Exposed surfaces to have acrylic render soffit to have acrylic render system in accordance with manufacturers
system in accordance with manufacturers specifications. 2,030 3,750 950 specifications.
Concrete block wall to be in accordance with structural engineers design
and detail. Wall to be finished with acrylic render system with sponge
finish and painted.
Frameless clear glass panels to provide balustrade in accordance with
9,200
ABCB Housing Provisions Standard 2022 : 11.3 Balustrade panels to be
Ceiling
fixed with rebated 316 stainless steel glazing channel. Balustrade to be
Swimming pool and spa to be in accordance with engineers design and detail. All pool construction to be in a min. 1000mm high above finished floor level. Glass to have 25 x
accordance with manufacturers/installers specifications. Pool to have suitable pumps located in pool plant store in 25mm 316 stainless structural steel glazing channel top rail. Glass to be
accordance with manufacturers/installers specifications. Provide pool fence to be in accordance with ABCB Housing in accordance with AS1288.
3,000
Provisions Standard 2022, the Building Act 1993, Building Regulation 2006, AS 1926. Pool fence to be min. 1200mm 7,265
high above adjoining finished surface level and have 900mm non climbing zone as specified in pool legislation. Pool
to have structural acrylic wall to be in accordance with structural engineers and specialist manufacturers design and
detail. Pool to be finished with Cemher Provide Cemher Microdur® (Micro Cement render) system : Colour : Organic.
6,200
First floor
5,800
Glass pool fence to be in accordance with the Building Act 1993,
Building Regulation 2006, AS 1926 . Pool fence min. 1200mm high
3,500
Formed concrete columns to be in accordance with structural engineers
above adjoining finished surface level and have non climbing zone as
3,890 3,890 design and detail. Provide acrylic render system in accordance with
specified in pool legislation. Glass panels have 316 s/s offset point
manufacturers specifications.
fixings.
2,670
2,700 fniished coping level
Ground floor
1,900 Suspended concrete terrace to be in accordance with structural
engineers design and detail. Provide fall to outside line of building.
Provide EmerProof waterproofing system. Exposed surfaces fascia &
3,200
soffit to have acrylic render system in accordance with manufacturers
700 specifications. Provide selected slip resistance tiles to be installed in
accordance with final colour selections.
-500
Basement
Formed concrete stairs to be in accordance with structural engineers
Concrete reventment wall to be in accordance with structural engineers
design and detail. Stairs to be in accordance with ABCB Housing
design and detail. Provide EmerProof water proofing barrier to wall with
Provisions Standard 2022 : 11.2 Stairs to have cantilevered treads with
root barrier guard and 100mm sleeved ag. drain, free draining back fill.
selected tile facings.
Wall to be in accordance with the Building Act 1993, Building Regulation 4 3 2 1
2006, AS 1926 . Wall to provide pool fence barrier min. 1200mm high
above adjoining finished surface level and have non climbing zone as
specified in pool legislation.
South Eastern Elevation
SE 1:100
/Users/benthornton/Documents/Cadfiles/2401 - Palazzesi/Archicad/
19062024/2401.pln
sbt designs pty ltd t/a
Skale Building Design project Residence lot no. 145 DA05 Development applicaiton issue 19/6/2024
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. N21859 DA04 Develoment application issue 23/4/2024
2401
skale
DA03 Develoment application issue 14/4/2024
skale.com.au 38 Mossman Court drawn BT
DA02 Develoment application issue 5/3/2024
drawing number
building design
[email protected]
A.C.N. 123 976 296 QBCC: 1143 609 at Noosa Sound scale (A2) 1:100 Rev Details Date 07 DA05 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file