                                                    Min 4.4m    to   the O
Rear                       Minimum 6 metres         garage



Building Height
                                                    2 storeys            P
 In Storeys                2 storeys
                                                    8 metres
 In Metres                 8 metres                                      P

Carparking                 1 covered per dwelling
                                                    4 covered
                           unit and 1 additional                         P




As detailed in the above table, the proposed development is fully compliant with
the key Probable Solutions of The Noosa Plan, except for, side setbacks to the
internal boundaries, rear setbacks, and Gross Floor Area which are further discussed
below:

Setbacks

Side Setbacks

Units 3 and 4 provide upper level setbacks of 1.85m and 1.6m to the internal side
boundaries. In accordance with Acceptable Outcome AO9 of the code, the
development is required to provide side setbacks of 2m where walls exceed 4.5m in
height. Despite the encroachment, the proposed setbacks are considered to meet
PO9 of the code. The encroachments relate to an internal boundary between the
two buildings and will not be perceivable from the site boundaries. The same built
form outcome could be achieved with a conventional 4 unit development;
however, in this instance it is sought that development be titled as two separate
duplex developments. The proposed outcome will not impact on the amenity of
adjoining premises in accordance with PO9 of the code.

Rear Setback

A garage and roofed patio associated with Unit 3 are setback 4.4m and 3m from
the rear boundary and subsequently encroach into the 6m rear setback area. The
proposed setbacks are considered to be sufficient to achieve Performance
Outcome PO9 of the code for the following reasons:

   •   the garage will have a maximum height of 3m and not present any openings
       to the boundary which could impact on the privacy of the units to the south.
   •   the roofed patio is an open structure and does not present an obtrusive bulk
       or built form to the boundary;




                                                                         Page 11 of 13

Used in these records

About this file

File size
4.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

TOWN PLANNING ASSESSMENT REPORT.pdf · 4.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.