Original source · versioned page text
D - Vehicular Site Access Advice
Attached to the e-mail MCU20/0037 - Response to Further advice - 11 Margit Crescent Sunrise Beach.
Performance Outcomes Acceptable Outcomes TTM Response/Justification
Driveways
PO1 AO1.1 Complies with AO1.1
Vehicular access does not adversely Vehicular access is located and designed The proposed vehicular accesses are
impact on safety, capacity and in accordance with the current Australian located and designed in accordance with
operations of the existing or planned Standards for Parking Facilities. AS/NZS2890.1:2004.
road network, the proposed
driveway, cycleways or pedestrian AO1.2 Complies with PO1
pathway systems.
Only one footpath crossing is provided. Two footpath crossings are proposed; one
for each proposed dwelling.
Editor’s Note— Justification for additional As identified in TTM’s response to the
driveways may need to be supported by a Further Issues letter the availability of on-
detailed Traffic Study. street car parking is not adversely
impacted.
All sight distance requirements stipulated in
AS/NZS 2890.1:2004 can be achieved by
the proposed design.
The provision of two accesses is not
expected to result in any adverse impacts
to the pedestrian and cyclist pathway
system.
Additionally, it is noted that there is an
existing precedence of properties whereby
multiple footpath crossings are provided
which do not adversely impact the safety,
capacity and operations on the existing
network as shown in the previous RFI
response compiled by TTM.
AO1.3 - Driveways, have a maximum Complies with AO1.3
grade in accordance with Council’s Detailed design and construction of the
standard requirements. access crossovers is anticipated to be in
accordance Council’s standard
requirements.
PO2 AO2.1 Complies with PO2
Driveways and crossovers Design and construction of driveways, The proposed vehicular accesses have been
a) are suitable and safe for including across the footpath, is in designed in accordance with a Type 2
their intended use; and accordance with Council Standard access as stipulated in Council Standard
b) match Council Drawings as appropriate for the particular Drawing RS-049. It is acknowledged that
infrastructure. type of development as annotated on the the development is for a Duplex for which a
drawings. Type 5 access strictly applies. However, the
proposed dwellings are practically Single
Houses for which Type 2 access applies.
AO2.2 Complies with AO2.2
The change of grades in driveways and Detailed design and construction of the
ramps is in accordance with Council’s access crossovers is anticipated to be in
Standard Drawings. accordance Council’s standard drawing RS-
050.