3.2 Flood Immunity Level Requirements
Table 8.2.6.4 of the Flood Hazard Overlay Code nominates the minimum floor level
requirements for residential developments as presented below:
• Accommodation Activities = DFE + 300mm
The resulting minimum floor level for the proposed dwelling is therefore RL3.50m AHD.
The proposed development involves constructing a dwelling at RL3.50m AHD. The floor level
of the proposed dwelling therefore complies with the minimum flood planning level as
specified above.
The proposed dwelling is to be structurally designed to be able to resist hydrostatic and
hydrodynamic loads associated with flooding up to and including the 1% AEP flood event
(maximum flow velocity of 1.20m/s and maximum flood depth of 0.7m).
Water-resistant materials are to be utilised for non-habitable structures to reduce potential
for flood damage.
The Flood Hazard Overlay Code has been addressed in Appendix D of this report.
9
1534 Louis Bazzo Drive, Cootharaba FLOOD SMART
26-148 ENGINEERING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Flood report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.