REFER TO SHEET 1 (COVER SHEET) FOR
ALL BUILDING INFORMATION REGARDING:
BAL-12.5 BUSHFIRE REQUIREMENTS PROVIDE AND INSTALL 3 PHASE REVERSE CYCLE AIR
CONDITIONING SYSTEM. NUMBER AND POSITIONING OF
HATCHED AREA INDICATES
- SUSTAINABILITY REQUIREMENTS 1200x900 CLEAR SPACE IN FRONT SEE SHEET 1 (COVER SHEET) FOR DETAILS OUTLETS AND THE FINAL LOCATION OF THE RETURN AIR
- SITE CLASSIFICATION OF PAN AS REQ'D BY 2022 NCC GRILLE WILL BE DETERMINED ON SITE BY THE AIR
- GENERAL BUILDING INFORMATION CONDITIONING CONTRACTOR AND IS SUBJECT TO TRUSS
LAYOUT AND ANY OTHER CONSTRUCTION CONSTRAINTS.
ALL MECHANICAL VENTILATION TO BE
DISCHARGED TO OUTDOOR AIR AS PER FRAME MANUFACTURER TO PROVIDE CLEARANCE FOR
NCC 2022 REQUIREMENTS PASSAGE OF FAN COIL UNIT FROM RETURN AIR OPENING TO
FINAL FAN COIL LOCATION.
ALL EXTERIOR STEPS AND LANDINGS BY 2,035
CUSTOMER UNLESS NOTED OTHERWISE 243 1,550 243 ANY PART OF THE FASCIA, GUTTERING OR DOWNPIPE THAT
243 1,550 243 IS WITHIN 450mm OF ANY BOUNDARY IS TO BE NON-
ALL GROUND FLOOR BULKHEAD AND 32,100 Overall COMBUSTIBLE IN ACCORDANCE WITH NCC 2022
SQUARE SET OPENING FRAMES TO BE 25,370
110 650 160
75 770 75
2340 ABOVE FFL UNLESS NOTED 7,990 4,950 5,650 6,780 6,730 ALL EXTERIOR SLABS TO BE GRADED BY CONCRETER TO
920
OTHERWISE CUTOUT ACHIEVE APPROX. 1:100 FALL TO OUTSIDE EDGE WITH
1,070 2,390 4,530 2,990 1,960 450 610 1,710 2,410 470 267 6,246 267 830 1,810 1,570 1,810 710
MAXIMUM CROSSFALL OF 30mm OVER ENTIRE SLAB.
ALL GROUND FLOOR INTERNAL DOORS TO 225 3,105 Bed 4 75 3,100 Bed 3 225
BE 2340 HIGH UNLESS NOTED OTHERWISE 2,035
225 1,990 75 1,040 75
Robe Bed 4
REFER TO WINDOW AND DOOR BATH HOB DETAIL 225 7,540 Garage 225 4,950 Grand Outdoor Living 225 1,675 75 3,300 Kitchen 75 75 225 6,780 Grand Outdoor Living 315 1,900 Pdr 75 2,155 Hall 75 1,985 Robe 225
WIP V
SCHEDULES FOR FULL DETAILS OF ALL 1650 75 1,500 Hall 150 3,600 Ldry 75 150 7,750 Meals / Living 75 1,395 Pdr 75 75 1,985 Bath 225
WINDOWS AND DOORS. PLEASE NOTE FRAME 530 HIGH 75 1,500 WC 150 2,970 75 1,675 150 3,855 Kitchen 150 75 1,395 WIL 75 1,040 75 3,100 Bath 225
WINDOW AND DOOR SIZES ARE BASED ON V WIP Hall
BATH TO BE INSTALLED MAX. 95mm FROM 75 2,595 WIR 75 1,950 WIR 75 5,680 WIP / Kitchen 150 90 4,920 Children's Activities 225 750
MANUFACTURERS SPECIFICATIONS AT
DEPOSIT STAGE AND MAY DIFFER
WALL FRAME AT LOCATION OF SPOUT 75 1,675 WIP 150 1,020 75 660 75 2,025 150
Ref Recess Kitchen
A1
13
13
SCALE 1:100
A
SLIGHTLY TO THE SIZES NOMINATED IN
TANK WATER
THE SCOPE OF WORKS DUE TO YARD TAP
MANUFACTURING CHANGES AT THE TIME SF1518 SF1518
225
225
225
DP-C
DP-C
OF CONSTRUCTION.
LD
LD
185 4,965 185 5,280 185 6,780
FINAL WINDOW AND EXTERIOR DOOR W10 W09
DP-C DP-C DP-C
185
LOCATIONS MAY BE ADJUSTED ON SITE LD LD LD
2,895 Bed 4
TO SUIT BRICKWORK GAUGE
3,500 Bed 3
EDGE OF RAISED CEILING
3,500 Bed 4
Grand Outdoor Living
3,750
185 x 185mm NOM. MERBAU POST BEAMS OVER TO
LIGHTWEIGHT CLADDING
4,550
PROVIDE ENERGY EFFICIENT LIGHTING TO
MANUF. SPECS
BED 4 BED 3
4,195
PROVIDE ONE HOT & COLD
OVER DOOR
GRAND OUTDOOR LIVING
2,365
CAPPERD WATER POINT
A MINIMUM 80% OF TOTAL FIXED (PB)
5,210
HOT WATER SERVICE TIMBER REVEALS TO @ 400MM FFL AND WASTE 2 x 770 SMARTROBE
3,350
HOT WATER SERVICE
(NO CONCRETE)
ARTIFICIAL LIGHTING AS REQUIRED BY
50mm SLAB
DRAINAGE POINT FOR FUTURE S/O 1570
SETDOWN
TANK WATER GARAGE OPENING W12 W11 (MIRROR)
75 1,430 75 530 75
CONNECTION BY OWNER
MP4.1 - (A3) SUSTAINABLE BUILDING YARD TAP DP-C 2 x 820 SMARTROBE
S/O 1670
Robe
7,250
LD 850 A/F1806 FSSF1224 ROBE
225
225
225
225
225
225
TAP LOCATION
DP-C
D03 TAP LOCATION
205
(MIRROR)
75
75
75 1,100 Hall 75
75 530 75
LD
PAINTED FC SHEET OVER DOOR 870 870
UNLESS NOTED OTHERWISE
75
800
A RECESSED DIRECT STICK
Robe
75
BRICKWORK OVER DOOR
800
ROBE
720 UC
630
ALL ROOMS ARE REFERENCED
800
800
GAS
200
75 725 V SF2418 FSSSSF2462 PDR
900
Pdr
600
#
225
225
225
225
D B
AIR CON
2270 MAX HEIGHT ROLLER
Pdr
1,250
AS FOLLOWS:
HWS
350
2,355 Recess
800
600
570
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Flood report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.