Council archive · source document
Appendix G - Council Code Responses · MCU22/0051
Medium Impact Industry
Performance outcomes Acceptable outcomes Solution Comments
Waste Storage AO22 Acceptable outcome Complies
PO22 Waste storage areas are visually screened by Waste storage areas will be contained within the
Waste storage areas are screened from the street landscaping or fencing. building or located in the loading dock at the rear
and adjoining of the building.
properties by buildings, landscaping or fencing and
do not detract from the visual amenity of the
streetscape or cause nuisance to adjoining
properties.
External storage and display of goods AO23 N/A Not Applicable
PO23 Materials stored outside buildings do not Materials associated with the use will
Storage areas are screened from the street and exceed half the height of the on-site buildings predominately be stored within the building.
adjoining properties or if there are no on-site buildings, the stored
by buildings, landscaping or fencing. materials do not exceed 4 metres.
Vandalism AO24 Acceptable outcome Complies
PO24 Buildings or structures that are visible from and No front fencing is proposed, and frontage
Buildings and structures are designed to minimise accessible from a public street or laneway: landscaping will prevent access to the building’s
opportunities for a. avoid the use of solid fences and blank front wall, which will deter graffitiing.
vandalism. walls which attract graffiti or where solid
blank surfaces are unavoidable, employ
measures in the form of landscaping,
creepers, murals, vandal resistant paint;
b. with windows at ground level use measures
that deter break and enters; and
c. are constructed to be vandal and graffiti
proof.
Lighting AO25.1 Acceptable outcome Complies
PO25 Lighting of appropriate intensities is provided All lighting associated with the proposed
Lighting of appropriate intensities maximises which satisfies the requirements of Australian development will be provided in accordance with
safety. Standard AS1158: Public Lighting Code unless the relevant standards and conditions.
otherwise specified in this Code.
Current as at 31 July 2020 Noosa Plan 2020
Page 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix G - Council Code Responses.pdfRelated documentApplication case desk ↗
About this file
- File size
- 834 KB (small file)
- File type
No other editions are linked here.