Council archive · source document
06/0952 - Response to information request dated 07/06/06 [As Published] · 132006.952
DOUBLE CHECK VALVE CONNECT STORMWATER SOLENOID JO STREET KERB ELIZABETH STREET SITE LEVELS LEGEND 2 MAINS. SUPPLY => TO APPROVED RETICULATION SYSTEM 150X100RHS GALV TO FOOTPATH CROSSING @ 1:80 CONCRETE CARPARK CONSTRUCTION NOTES: 1/ ALL CONCRETE TO CARPARK TO BE Fie = 32MPo 1.8 2/ SLUMP 50mm — 80mm 3/ MAX WATER/CEMENT RATIO. = 0.8 A™ Cn CABLE FROM FLOAT SWITCH ‘BY FLOAT SWITCH ‘A’ PUMP MODEL TO BE NOTES: DETERMINED FOR PARICULAR USE. THE FLOAT SWITCH (A) SHALL BE WIRED SO THAT AT LOW WATER LEVEL THE POWER SUPPLY TO THE PUMP SHALL BE ISOLATED (VIA THE RELAY) AND AT THE SAME TIME THE SWITCH WILL ACTIVATE THE SOLENOID SUCTION LINE FROM 4/ FINISH SURFACE OF CONCRETE WITH A LIGHT BROOM 5/ CCJ - CRACK CONTROL JOINTS AS SHOWN CUT EVERY SECOND TRANSVERSE STRAND OF FABRIC CROSSING JOINT, FORM JOINT WITH GROOVING TOOL WHILE CONCRETE IS STILL GREEN. 6/ PROVIDE KEYED CONSTRUCTION JOINTS AS REQUIRED 150¢ UPVC _@ 1:80 RAINWATER PUMP DETAIL 7/ CONCRETE 150mm THICK REINFORCE WITH NOT TO SCALE TO ALLOW MAINS PRESSURE WATER TO SUPPLY No.1~LAYER FB2 FABRIC 40 MIN TOP COVER. THE SYSTEM, AS THE TANK RE-FILLS WITH RAINWATER THE FLOAT SWITCH (B) WILL SIGNAL AND THE SYSTEM SHALL REVERT TO NORMAL. (SOLENOID OFF AND PUMP ON) EARTHWORKS NOTES: 1/ THE TOP 150mm OF THE SUBGRADE SHALL BE COMPACTED TO NOT LESS THAN 95% OF THE MODIFIED MAXIMUM DRY # __ EXISTING SITE LEVELS 1.759 & A PROPOSED FINISHED LEVELS x INDICATES 1:100 YEAR a OVERLAND FLOW PATH QUEENSLAND DEVELOPEMENT CODE PART 25 (WATER SAVING TARGETS) NOTE : ONE 3000 LITRE WATER STORAGE TANK TO EACH UNIT, LOCATION AS INDICATED ON PLAN. TANK TO BE CONNECTED TO AT LEAST ONE EXTERNAL HOSE PIPE AND INTERNALLY TO TOILET CISTERN AND WASHING MACHINE COLD WATER TAPS. TANKS CONNECTED TO INTERNAL FIXTURES TO HAVE A BACK-UP SYSTEM CONNECTED 10 COUNCIL MAINS, ALL INSTALLATION TO BE IN ACCORDANCE WITH THE LOCAL AUTHORITY REGULATIONS. DENSITY AS DETERMINED BY AS1289. 1508 UPVC @ 1:30 @ FORM 10 BOUNDARY OR GARDEN BED DWELLING 2 = (220SQ.M ROOF AREA) 1.479 # ee oS , # \ 2 | 1.498 Ke % ; 1.812 DWELLING 1 = (200SQ.M ROOF AREA) TYPICAL CARPARK EDGE DETAIL SCALE 1:20 AS/NZS 3500.3.2 : 1998 ROOF CATCHMENT DETAILS (FO! DOWNPIPE SIZE AND LOCATION INDICATED FROM ARCHITECTURAL DOCUMENTATION PE DESIGN OWELLING 1 ROOF AREA = 200m? Co-eff RUNOFF = 1.0 1 = 160mm/HOUR (1:2 YEAR Rl) Q=8.8 L/sec . 1.5 2 DWELLING 2 # : . ALL DOWNPIPES 100¢ UPVC ONO ROOF AREA = 220m! Co-eff RUNOFF = 1.0 =H 1 = 160mm/HOUR (1:2 YEAR Rl Lt D 0297 tye, ) _ +: a — 605 P 3000L WATER / STORAGE WITH FIRST FLUSH REFER NOTES NOTES : MIN FINISHED FLOOR LEVEL OF OWELLING UNITS TO BE 2.5m AHD ALL STORMWATER U.N.O 1008 UPVS 1:80 FALL(TYPICAL) eee J tet (OES eo 3O00L WATER UMP LOCATIOY STORAGE WITH FIRST FLUSH REFER NOTES PAN CATCHMEN AILS (FOR PIPE DESIG AREA = 320m? Co-eff RUNOFF = 1.0 | = 160mm/HOUR (1:2 YEAR Ri) = 14.2 L/sec ALL GPT’S TO BE EQUAL 70 FOX 8G PCT + FB (TYPICAL) REFER DETAIL. 536 SITE PLAN SCALE 1:200 PUMP LOCATION REFER DETAIL PROPOSED DUPLEX 48 ELIZABETH STREET NOOSAVILLE QLD CONSULTING ENGINEERS ARTECH PROPERTY 4 Easton Street (Cnr Maud Street}, Maroochydore QLD 4558 Telephone (07) 5443 6585 Facsimile (07) 5479 1754 Postal Address PQ Box 5960 Maroochvdore BC QLD 4558 DIMENSIONS AND LEVELS PRIOR TO THE SCALE _AS_SHOWN COMMENCEMENT OF ANY CONSTRUCTION. DATE FEB 2007 ~ CONTRACTOR TO NOTIFY ENGINEER IMMEDIATELY IpRAWN MT A\_STORMWATER | oF ‘any DISCREPENCIES, EVENT 001 Cf | cape omens 10 135% 206170 J SCALED MEASUREMENTS. VERIFY ALL ON SITE [| JOB DESCRIPTION
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0952 - Response to information request dated 07/06/06 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.