Response to Council Information Requests · MCU22/0118
“Adamson Town Planning, specialising in providing higher order town planning advice”
The amended Landscape Concept Plan does not refer to the above mentioned plant species
in the Landscape & Revegetation Planting list (Dwg No. LC03 – Attachment 2).
Issue
Flood Immunity Requirements
Information Required
2. Obtain a flood search certificate for the site and demonstrate that the minimum surface and
floor levels required by Table 8.2.6.4 of the Flood Hazard Overlay Code are achieved for the
car park, walkways and buildings proposed for the site.
According to the Flood Hazard Overlay, the site is only partially affected by flooding towards
the northwest where no development is being proposed (refer Figure 2). In any event, it is
noted that the cabins are located typically about 600mm above the natural service level, with
the proposed walkways also being elevated. Further, the proposed carpark area will be
constructed about 300mm above the natural service level. The consulting engineer (ADG) has
advised that the proposed cabins are to have a minimum RL3.4m (AHD) with the flooding
extent under the overlay having an RL2.4m (AHD).
Figure 2 – Extract of Flood Hazard Overlay mapping
Issue
Stormwater Quality Targets
The site discharges directly to HEV waters. PO6 and AO6.1 of the Water Quality and Drainage
Code requires that sites discharging to HEV waters also demonstrate ‘no increase’ in pollutant
loads in addition to achieving the SPP2017 load reduction targets. This has not been
demonstrated.
Information Required
12 | P a g e
18006 – RACV Noosa Resort, December 2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Council Information Requests.pdfRelated documentApplication case desk ↗
About this file
- File size
- 462 KB (small file)
- File type
No other editions are linked here.