FLAT ROOF AREAS

 

RADIATA PINE ROOF TRUSSES @ 900 CRS FITTED IN
ACCORDANCE WITH MANUFACTURER'S SPEC.

 

TO T DEGREES WATERPROOF MEMBRANE =
TO MANUFACTURERS SPEC

(SLOPE AS DIRECTED BY ROOF PLAN) om LINE cee?

max.
20° ROOF PITCH - ~~~”
SUSPENDED CONCRETE

FLOOR SLAB AS PER
ENGINEER'S DESIGN.

LINE

 

 

40MM RENDER WITH
FINE SAND FINISH ’
3 COATS OF r '
WATERPROOF TYPE PAINT _! :

 

MaArs.0@

 

 

 

200 SERIES BLOCKWORK TO
ENGINEER'S DETAILS

 

WITH MANUFACTURER'S SPEC. FOR W41 WIND LOADS.

ENSURE PARAPETS ARE PROPERLY
WATERPROOFED

FLAT ROOF LINE

” om SETBACK LINE

 

“ BOUARDRY LINE |
/_2m SETBACK LINE

LEVEL 2 CEILING LINE

 

LEVEL 2 - GUEST FLOOR LEVEL

—*

oT 200 UM WATERPROOF MEMBRANE

TREATMENT AGAINST TERMITE
ATTACK (TERMIMESH OR SIMILAR)

REINFORCED CONCRETE
SLAB AND FOOTINGS

SECTION BB

FLAT ROOF AREAS
TO 1 DEGREES WATERPROOF MEMBRANE
TO MANUFACTURERS SPEC
(SLOPE AS DIRECTED BY ROOF PLAN)

 
 
 
  
 
 
 
  
 
      
 

SUSPENDED CONCRETE
FLOOR SLAB AS PER
ENGINEER'S DESIGN.

20° ROOF PITCH
40MM RENDER WITH
FINE SAND FINISH
3 COATS OF
WATERPROOF TYPE PAINT

 

20° ROOF PITCH

 

RADIATA PINE ROOF TRUSSES @ 900 CRS FITTED IN
ACCORDANCE WITH MANUFACTURER'S SPEC.
CONCRETE ROOF TILES FITTED IN ACCORDANCE
WITH MANUFACTURER'S SPEC. FOR W41 WIND LOADS.

 

    
  

LEVEL 3 CEILING LINE

ENSUITE

 
    
 

RL 29.3

AIR CON

 

LEVEL 3

 

ED 1 FLOOR LEVEL

 

KITCHEN =

   

6m SETBACK LINE

RL 26,0. ----"

   

 

} 5
BOFAOM O01
\ oat
IX A LINE

BOTS
STORE ROOM

RL 22.8

 

REINFORCED CONCRETE
SLAB AND FOOTINGS
TO ENGINEER'S DETAILS

SECTION AA

CHRIS CLOUT DESIGN PTY LTD
12 WEYBA ST SUNSHINE BEACH

CHRIS CLOUT

design PO BOX 135, NOOSAVILLE, QLD 4566.
PH: (07) 54748 107 FAX: (07) 54748 108
Pty Ltd MOB: 0412 408 410 EMAIL: [email protected]

    
  
  
     
 
   
   
 
  
  
 
          
 
   
   
   

200 SERIES BLOCKWORK TO
ENGINEER'S DETAILS

200 UM WATERPROOF MEMBRANE
TREATMENT AGAINST TERMITE
ATTACK (TERMIMESH OR SIMILAR)

GENERAL NOTES:

Use written dimensions only. DO NOT scale drawings. Contractors to verify ali
dimensions on site prior to commencing works. Site location is Category W41
or to engineers requirments

These drawings are to be read in conjunction with engineer's design and details,
the accompanying building specification and schedule of finishes.

If in doubt, please request clarification. DO NOT ASSUME.

ENSURE PARAPETS ARE PROPERLY '
' WATERPROOFED :

FLAT ROOF LINE

LEVEL 4 CEILING LINE

LEVEL 4 BEDS FLOOR LEVEL

LEVEL 3 CEILING LINE

2700

LEVEL 3 GARAGE FLOOR LEVEL

LEVEL 2 CEILING LINE

2700

 

 

LEVEL 2 - PDR FLOOR LEVEL

CLIENT NAME: SAX, Brian & Andrea
SITE ADDRESS: Lot 17 Marcus Dunes Court, Marcus Beach

 

prawinctme: SECTIONS A-A B-B
DRAWING DATE: 28/08/07 } SCALE: 3:100 4:100 [DRAWN BY:C CLOUT BY: C CLOUT

AMENDMENT DaATes: PRELIMINARY

 

 

 

 

 

 

 

DRAWING No:

08.0

Used in these records

About this file

File size
3.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0242 - MCU - Detached House [As Published].pdf · 3.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.