09/0325 - MCU - Detached House [As Published] · 132009.325
Caloundra Building Approvals Pty Ltd 155 Bulcock Street, Caloundra PO Box 135 GOLDEN BEACH QLD 4551 Phone (07) 54914866 Facsimile (07) 54914877 The plans incorporate a basement carpark with a floor level below the finished ground level. The attached hydraulic plans provide details of the drainage for both the stormwater and sewerage plumbing. The basement area is only for the storage of cars and the floor level is approximately 2.3 metres below the driveway height. The hydraulics plan indicate both a sump pump.and back up pump as well. It is considered that the dual pump system will provide an acceptable solution to the required outcomes to allow only short term and infrequent flooding to non-habitable areas. The proposed development will not cause any flooding or drainage issues to adjoining properties; . The dwelling construction is to be concrete slabs and blockwork walls, which will also include a slab and truss roof of low pitch to 1 degree. slope. The design is such.to achieve parapet type fascias and overhangs to the majority of the dwelling with some limited areas of no overhang. These areas are well incorporated into the design and the roof lines willo not be apparent from the normal visual aspect. Eaves widths vary with the design and are only marginally under the required 75% of the perimeter. The overall design and aspect of the proposal is certainly one of varying lines both horizontally and vertically to provide a very pleasing amenity; . The site coverage at ground level is approximately 49% and the upper level approximately 38%. The ground level coverage is very minimally under the required 50% due to including the pool and spa area in the calculations, however without these included it complies with the planning scheme requirements. The upper floor is 34% site cover and 38% cover with the roofed outdoor area. It is considered that the bulk of the building will not be out of character with the general area, with various unit developments in the vicinity of the allotment and the building will have quality landscaping to soften any perceived bulk impact; The spa height adjoining the northern boundary will be approximately 1.8 metres high with a block screen wall to 1.6 metres high above the spa and extending 1.0 metre each side of the spa. The overall length of the high wall will be approximately 5.1 metres. This proposal is to provide privacy for both the occupants and the adjoining neighbour. The adjoining neighbour has provided a letter of acceptance for the proposal. The proposal will provide adequate distance between the neighbours and have minimal impact on the adjoining property; at . The dwelling has been designed to comply with the energy efficiency requirements of the Building Code of Australia; we, . The overall design of the proposed dwelling has been carefully undertaken over a lengthy period to achieve a practical solution to the owners requirements and at the same time provide a very _ aesthetically pleasing outcome from the street and neighbourhood. Ground levels externally have minimal changes to alleviate any drainage issues to adjoining allotments.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/0325 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 8.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.