APPENDIX F - Acoustic Report
Attached to the e-mail MCU18/0204 - Development Application - 6 Heron Street, Peregian Beach.
RENZO TONIN RON RUMBLE 1 SEPTEMBER 2017
Table 3: Acoustic Quality Objectives– EPP (Noise) 2008
Acoustic Quality Objectives (dBA)
Sensitive (measured at the receptor)
Time of Day
Receptor
Leq, adj, 1 hr L10, adj, 1hr L01, adj, 1hr
Dwelling Daytime and 50 55 65
(outdoors) evening
Dwelling Daytime and 35 40 45
(indoors) evening
Night time 30 35 40
Commercial and When activity is 45 N/A N/A
retail activity (for open for business
indoors)
Park and Garden Anytime The level of noise that preserves the amenity of the
existing park or garden
It is noted that the Acoustic Quality Objectives are intended to be progressively achieved as part of
achieving the purpose of this policy over the long term.
4.3 Office of Liquor and Gaming Regulations (OLGR)
The Office of Liquor and Gaming Regulation sets limits for the noise of entertainment and patron
emanating from licensed premises. The limits apply at any noise-sensitive receptor as defined under the
Act, which includes private residences, caravan parks, marinas, schools, hospitals and the like. They also
apply to commercial premises that operate when the licensed premise intends to host entertainment.
The measured parameters and the noise limits vary depending on the time of day that the entertainment
occurs.
Between the hours of 6am and 10pm, the required method of measurement is the overall, A-weighted
noise level (dBA). The intrusive noise at the receptor is measured as the ten-percentile statistical level
(LA10) and adjusted for tonal and impulsive components (LA10 adj). The background level is measured as the
ninety-percentile level in the absence of entertainment (LA90). The noise limit for this time period is such
that the adjusted intrusive level must not exceed the background by more than 10dBA:
L A10 adj L A90 10dBA
Noise due to patrons may a different characteristic of sound from the existing ambient noise. To account
for this, it is appropriate to add a +5dBA penalty adjustment to the noise emissions before comparing it
with the ambient noise. The noise limit is derived in Table 4.
Table 4: Noise limits (LA10 adj) (Between 7am to 10pm)
Representative LA90 Tonal / Impulsive
Tolerance L10 adj
Background Noise Level Adjustment
48dBA – Refer to Table 2 -5dBA +10dBA [48 - 5 + 10] = 53dBA
COX ARCHITECTURE OUTDOOR RESTAURANT DECK (LEVEL 2) - 6 HERON STREET,
QB143-01F02 ACOUSTIC REPORT (2) PEREGIAN BEACH
6 PATRON NOISE ASSESSMENT
See the original