Original source · versioned page text
Rfi - Landscape
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
DETAILED LANDSCAPE DOCUMENTATION
65-67 ELANDA STREET, SUNSHINE BEACH Q
LANDSCAPE SPECIFICATION 2.4 Compost and Fertiliser
Compost
diameter. Keep organic and inorganic mulch not closer than 50mm from plant stems.
Depths: Spread organic mulch to the nominated depth or a minimum depth of 100mm.
NOTES General: Provide well rotted vegetative material or animal manure, free from harmful chemicals,
grass and weed growth as per AS 4454.
6.0 PLANT SUPPORT
Fertiliser 6.1 Stakes and Ties
1.0 GENERAL General: Apply Agriform or similar slow release tablets at the following rates. Stakes
1.1 Standards Trees 4 Tablets. Shrubs 3 Tablets. Ground covers 1 Tablet. Add a handful of Dynamic Lifter Requirement: Generally, plants of good quality should be self-supporting, however stake plants
and water in well each 4 weeks during the establishment period. Fertilize turf areas with located in open ground or adjacent to vehicular traffic or as directed to mark their location or
§ Soils to comply with AS 4419-2003 - Soils for Landscaping and Garden Use.
Dynamic Lifter at the rate of 250 grams per 5 m2. provide additional protection.Material: Hardwood, straight, free from knots or twists, pointed at
§ Compost, soil conditioners and mulches to comply with: to AS 4454. one end.
§ AS 4970 - Protection of trees on development sites 3.0 PLANTS Installation: Drive stakes into the ground for at least a fifth of their length, avoiding damage to
§ AS 4377 - Pruning of Amenity Trees the root system. Place stake at a clear distance of 50mm from the edge of the rootball.
§ NATSPEC reference book: Specifying Trees - a guide to assessment of tree quality 2003 by 3.1 General Plants 2.5m high: Three 50x50x2400mm stakes per plant.
Ross Clark General: Provide plants with the following characteristics: Plants 1.0 - 2.5m high: Two 40x40x1800mm stakes/ plant.
§ Large healthy root systems, with no evidence of root curl, restriction or damage. Plants 1.0m high: One 30x30x1200mm stake per plant.
2.0 SITE AND SOIL
2.1 Preparation
§ Vigorous, well established, free from disease and pests, of good form consistent with the
species or variety.
Ties CONTEXT MAP
General: Provide hessian or equivalent non-abrasive ties fixed securely to the stakes, REFERENCE SCALE
Weed eradication § Hardened off, not soft or forced, and suitable for planting in the natural climatic conditions preferably one tie at no more than one-third of the main stem, others as necessary to stabilise
Herbicide: Eradicate weeds using environmentally acceptable methods, such as a non-residual prevailing at the site. the plant.
glyphosate herbicide in any of its registered formulae, at the recommended maximum rate. Supply: Supply plants that are propagated in a nursery facility that have been accredited by the
Manual removal of weed undergrowth: Regularly remove, by hand, rubbish and weed growth Nursery Industry Association of Australia 7.0 IRRIGATION
throughout grassed, planted and mulched areas. Remove weed growth from an area 750mm
diameter around the base of the trees in grassed areas. Continue eradication throughout the
Replacement: Replace damaged or failed plants with plants of the same type and size. 7.1 General DRAWING REGISTER
course of the works and during the planting establishment period. 3.2 Plant Containers and Stock Sizes Install automatic irrigation to all common areas, and individual tap computers to private
Vegetative spoil General: Supply plants in weed free containers of the required size. courtyards where applicable. Water to be pump fed from on site rain-water tanks connected to Drawing No. Drawing Title Issue
down-pipes and storm-water system.
Remove vegetative spoil from site. Do not burn.
20-00902-CS01 COVER SHEET C
Site topsoil 4.0 PLANTING
20-00902-LP01 LANDSCAPE LAYOUT PLAN C
Remove Strip topsoil from known areas of construction and stockpile in an appropriate area so 4.1 General 8.0 COMPLETION
that drainage and construction is not restricted. Make sure that the soil cannot flow out of the 20-00902-LP02 GROUND FLOOR PLANTING PLAN C
Individual tree stock in grassed areas and planting in beds: Excavate a hole to at least twice the
site in a storm situation and infiltrate the storm water system. Erect silt barriers to protect S/W
system.
diameter of the rootball and at least 1.5 times deeper than the rootball. Break up the base of 8.1 Planting Establishment 20-00902-LP03 ROOFTOP LANDSCAPE PLAN C
the hole to a further depth of 100mm, and loosen compacted sides of the hole to prevent
Establishment Period
2.2 Subsoil confinement of root growth. 20-00902-LP04 TYPICAL LANDSCAPE DETAILS C
Commencement: The planting establishment period commences at the date of practical
Cultivation 4.2 Watering completion inspection. Unless nominated differently continues for a minimum period of 12 20-00902-LP05 PLANTING SCHEDULES C
Cultivation depth to existing subgrade: 150mm unless specified otherwise. Requirement: Thoroughly water the plants before planting, immediately after planting, and as weeks or until the works are accepted on-maintenance by the Local Council Authority.
Cultivation depth to garden areas: 300mm unless specified otherwise. required to maintain growth rates free of stress. Existing planting and grass
Cultivation depth to turf and grass areas: 100mm unless specified otherwise. Watering basins for plants in grass: Except in irrigated grassed areas and normally moist areas Where existing grass or planting is within the landscape contract area, maintain it as for the
and impervious subsurface strata, construct a watering basin around the base of each corresponding classifications of new grass or planting.
Services and roots: Do not disturb services. Keep clear of tree roots in drip zone. Cultivate by
hand if necessary.
individual plant, consisting of a raised ring of soil capable. LANDSCAPING CALCULATIONS
Recurrent works
2.3 Topsoil 4.3 Placing Throughout the planting establishment period, carry out maintenance work including watering, SITE AREA GROUND FLOOR ROOFTOP
Remove the plant from the container with minimum disturbance to the rootball. Ensure that the mowing, weeding, rubbish removal, fertilising, pest and disease control, reseeding, returfing,
Source
rootball is moist and place it in its final position, in the centre of the hole and plumb, and with staking and tying, replanting, cultivating, pruning, hedge clipping, aerating, reinstatement of
General: Import topsoil unless the topsoil type can be provided from material recovered from
1020m2 471m2 40.2% 269m2 26%
the topsoil level of the plant rootball level with the finished surface of the surrounding soil. mulch, renovating, top dressing, and keeping the site neat and tidy.
the site.
4.4 Fertilising Replacements
Placing topsoil
In planting beds and individual plantings, place fertiliser pellets around the plants at the time of Continue to replace failed, damaged or stolen plants. Replacement plants are to match the
General: Spread the topsoil on the prepared subsoil and grade evenly, making the necessary planting. species and sizes outlined in the planting schedule. GROUND FLOOR HARD SOFT
allowances to permit the following:
54.5 Backfilling Grassed areas LANDSCAPING LANDSCAPING LANDSCAPING
§ Achieve required finished levels and contours after light compaction.
Commence grass maintenance works at the completion of sowing,
§ Finished surface levels of grassed areas to be flush with adjacent hard surfaces such as Backfill with topsoil mixture. Lightly tamp and water to eliminate air pockets. Ensure that 170m2 301m2
topsoil is not placed over the top of the rootball, so that the plant stem remains the same height hydroseeding and turfing. Maintain healthy weed free growth. Grass coverage must achieve at 471m2
kerbs, paths and mowing strips.
above ground as it was in the container. least 80% at the time of practical completion. 36.0% 64.0%
Finished surface levels of mulched areas to be 25mm below adjacent pathways, kerb or the
like.
Consolidation
5.0 MULCHING
5.1 General
PP
Compact lightly and uniformly in 150mm loose layers. Avoid differential subsidence and 89°56'36"
excess compaction. Produce a finished topsoil surface that has the following characteristics: General: Organic Mulch shall be free from stones, soil, clay, dust, weeds, seeds, roots, sticks, DP DP
179°58'36"
§ Finish to design levels. rubbish, vermin, insects, pests, fungus, disease and other deleterious material. It shall be free
from matter toxic to plant growth.
§ Smooth and free from stones or lumps of soil.
359°59'36"
STREET
STREET
Type: Mulch shall be Natramulch or Hoop Pine Fines
§ Graded to drain freely, without ponding or concentration of flows to catchment points.
§ Graded evenly into adjoining ground surfaces. 5.2 Organic Mulch Installation
§ Ready for planting. General: Place mulch to the required depth, clear of plant stems, and rake to an even surface
DP
flush with the surrounding finished levels. Spread mulch to the specified thickness so that after
Topsoil depths
settling, it is smooth and evenly graded between design surface levels sloped towards the base 179°58'36"
ELANDA
ELANDA
DP 3.138
Planting areas generally: As specified otherwise 300mm. of plant stems in plantation beds. Telstra Pit
359°59'36"
Grassed areas generally: As specified otherwise 150mm. In mass planted areas: Place after the preparation of the planting bed but before planting and
Tree pits: As specified otherwise 800mm. other work.
Podium and containterized planters: As specified otherwise, 1000mm for small trees, 600mm In smaller areas (e.g. planter boxes): Place after the preparation of the planting bed, planting
for medium to screening shrubs, and 300mm for small shrubs and ground covers. and other work.
9"
29'2
Extent: To surrounds of plants planted in grass areas, provide mulch to a minimum of 600mm DP DP
197°
UP
269°56'38"
GROUND FLOOR LANDSCAPING ROOFTOP LANDSCAPING
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: COVER SHEET
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-CS01 C
C SL 21/12/21 RFI RESPONSE scale:
- Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP REFERENCE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - COVERSHEET refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 6 sections
Section 2
ROAD CROW
.08 .40 1 71 .69 .19 .79
.85 46 52 51.0 3.95 510.
R52.67
45 .39 55 55 51
.5
45 .0 4
47 54 52..77
30 5
54
.9 2 SECOND LEVEL .14 R52.48 POOL/DECK
45
Top 51.71
Bot 50.84
4.9 47
Window
PP 5.27 .55LOWER
K&C
. 0 5 AREA
50 5 7
SEWER LINE
4 7 WALL
4
43.0
D44.70
1076
.89 91 GARDEN 5 45.12
42.5
TIMBER GARDEN EDGE D44.69
471
.0
Separating garden beds from public verge .81 45 . 3 9 7 1 LEVEL 74 70
45
.74 . 3 0 BOUNDARY .91 9 .26 61
455.73 45 45.2 .7 .7 RETAINING WALL . 89°56'36"
43.5
44 TIMBER PAILING FENCE43.6 . 2
41. 41. 41.1.11
PROPERTY 33.544M | 89° 56' 36"
45
turf. Refer Typical Detail 04/LP05 45 0 4 4444 42 42 42
. 8 OUTSIDE 4
45 .25 7000L TANK 7000L TANK
PROTECT EXISTING TREES
0 45 EA 5
NEW CONCRETE FOOTPATH
4 5 .7
.7 6 WALL 41. Retain and protect existing mature
Install 1.5m wide broom finished concrete 45
0
RL 43490 RL 43490
39 trees on adjoining property. Refer
.29
4.64 41.
43
DP
6
179°58'36"
DP
footpath to local council requirements . Specification Notes
4545
OW
.36
+T
45 190mm STEP
POOL
9 .49 0 BED TREE
5.5
BATH
EXTENT OF NEW BITUMEN
4545.4
PROPERTY BOUNDARY 15.091M | 359° 59' 36"
Ht = 8
Infill bitumen and install new kerb and 4 Spread = 15.0
.72
channel to match and align with adjoining Trunk = 0.60
property frontage. To future engineering 43 Type = NR
.6 1
SCOUR PROTECTION H4
.24
0
GARAGE
.89
45 and in accordance with local
design BFC UP INFILTRATION TRENCH AND
45 Select 70-150mm pebble treatment SYN
BUP100
41
STORMWATER CATCHMENT
359°59'36"
OW
council requirements over suitable weed matting + RL 42.415 4 TO CIVIL ENG'S DETAILS
3
41.
+B
DECK TE PRIVATE COURTYARDS- UPPER
LEISURE + RL 43.290
5 3380 TERRACES Timber deck stepping
TE
.4 LIFT
.5
45 3000
TIMBER PAILING FENCE
down to synthetic turf area on
45
UP
DRIVEWAY CROSSOVERS stabilized sand layer.
TE
5m wide select exposed aggregate
PROPERTY BOUNDARY 15.091M | 179° 58' 36"
1:6 1:4 1:6
2
concrete to local council requirements EA 1120
.4 EA
UP
45
TE
LIFT
STREET
RL 43597 LEISURE PRIVATE COURTYARDS - LOWER
+B
TE
DECK SYN
OW
TERRACE Mulched garden beds with
.07 1:8 + RL 43.290 + RL 42.415
41
45
.89
H3 UP tiered planting arrangement. Refer
0
GARAGE Planting Plan LP02 for detailed
SEWER MH SL41.8 planting design and schedule
TREE
Ht = 7
BATH Spread = 7.0
wer M/H BED
POOL Trunk = 0.30
.10 0
0
S
45 45.1
.05
DP
Type = PALM
Records 52
42
41.
190mm STEP SEW
OW
GRASSED ER
LIN
2
+B
E
AREA
ENTRY RL 43130
EA 43.9
.95 VISIBILITY TO NE
WIRE MESH FENCE
44 179°58'36"
BFC SWIMMING POOLS MINIMAL DUE TO
REINSTATE TURF TO PUBLIC VERGE DP
POOL
3.138
BED Including gates and fencing
To full width of public verge0excluding BATH 5100
.
45 footpaths .94 6 .7 1 to AS1926.1. Refer Architect
44 4.7 44 1
4 H2 .8
43
0
TREE
ELANDA
.94
1
4. 9
41
RL 43290 Ht = 7
Telstra Pit
.67
OW
4 GARAGE Spread = 7.0
44
+B
UP Trunk = 0.30
359°59'36"
RL 43290
2088 .40 Type = PALM
LEISURE
DECK 43
9"
+ RL 43.290 SYN MASONRY WALL <1000 HIGH
29' 2
LIFT
TE
+ RL 42.765 Select concrete block or 'Link'
.32
197°
1:6 1:8 UP
block retaining wall system
44
M|
TE
3.593
.45 560 41 .75
RY 1
RL 43415
44 LIFT
UP
ACCESS STAIRS
NDA
TE
1:8 SCOUR PROTECTION
EA Timber treads on steel stringers
BOU
EA Select 70-150mm pebble treatment LEISURE + BOW 41.940
for maintenance access
DECK SYN
TY
over suitable weed matting
PER
+ RL 42.765
.39
+ RL 43.290
PRO
44 RL 4 GARAGE H1
UP
.54
4 605 RL 43290
43 CP
PROPERTY BOUNDARY 16.098M | 359° 59' 36"
RL 43290
44.5 .37 TREE
4.2
0 44 Ht = 7
.39 4 .82 Spread = 7.0
BUP4358
COMMON GARDEN AREAS 44 BATH BED 41 Trunk = 0.30
29"
BFC POOL Type = PALM
Mulched garden beds with tiered planting 6
4 .1 .41
arrangement. Refer Planting Plan LP02 4 .1 6 44
29'
for detailed planting design and schedule 44 DP DP 2042 1800 TIMBER SCREEN FENCE
°
ENTRY PATH
UP TREE To side and rear property boundaries
197
PRIVATE ENTRY PATHS + BOW 42.500
317
Ht = 7
Select combination of tiled and exposed EA RL 43290
Spread = 7.0 and separating private courtyards
.26 34
42 42..97
aggregate surfaces as indicated Trunk = 0.30
.8 3 Type = PALM
Section 3
0
43 .5 41
.
42.5
269°56'38"
PROPERTY BOUNDARY 29.463M | 269° 56' 38"
TIMBER PAILING FENCE
LINE
2 0 3 7m
42
.15
1500
43
760
Top 47.85
Bot 46.37
44
Window
SEWER
.90
43 R48.57 R48.23
SCALE 1:150
EDGE OF BITUMEN
LEGEND 0 .85
44. 43
BROOM FINISHED SELECT EXPOSED OUTDOOR TILES SELECT 40MM SELECT 70-150MM TYPICAL MULCHED TYPICAL MASONRY WALL 1.8M HIGH TIMBER TIMBER EXISTING TREES
CONCRETE AGGREGATE SURFACE REFER ARCHITECT SYNTHETIC TURF DECORATIVE PEBBLE GARDEN BED TURF LESS THAN 1M HIGH SCREEN FENCE
TE GARDEN EDGE TO BE PROTECTED
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 1 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP01 C
C SL 21/12/21 RFI RESPONSE scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP GROUND FLOOR LANDSCAPE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 1 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 4
.5
45
(7) HIB Yel PP (1) CUP ana (25) LIR EG (5) FIC pum (1) PTY ele (2) COR hyb (3) COR hyb
Self adhering climbers (2) CLI min (15) LIR EG
43.0
42.5
.0
at foot of retaining wall (5) VIO ban (5) VIO ban (4) ACM smi
45
89°56'36"
43.5
(1) ELA eum
5
RL 43490 RL 43490
41. (6) COR hyb
(1) ACR imp
DP
179°58'36"
DP
(2) PTY ele
(7) FIC GI
(27) PHI XD
(8) VIO ban
(5) CAR DS
UP (10) ALP zer
(1) PTY ele
359°59'36"
(4) BAN rob
(3) HIB Yel
.5
(1) PAN tec (4) CLI min
45
UP
(4) ROS pro
1:6 1:4 1:6
UP
(3) ACM smi
(1) ELA eum (3) HIB Yel
RL 43597 (5) COR hyb
(4) CLI min
(1) ACR imp
STREET
(2) PTY ele 1:8
UP
(21) PHI XD (7) ALP zer
(4) ROS pro (10) DOO asp
(5) NEO BN
S DP (10) VIO ban
(4) CAR DS (1) PET tri
RL 43130
179°58'36" (3) ACM smi
(6) CAR DS DP (10) DOO asp 3.138 (1) ACR imp
(5) NEO BN
.0
45PHI XD
(27) (10) VIO ban
RL 43290
Telstra Pit
(4) COR hyb
ELANDA
UP
359°59'36"
RL 43290
(1) PTY ele
(1) PHE woo
(4) BAN rob (3) HIB Yel
1:6 (1) PAN
1:8 tec UP
(8) ALP zer
(4) ROS pro (1) 43415
RL ELA eum UP (1) ELA PD
(15) PHI XD 1:8
(1) PAN tec
(3) HIB Yel
(3) BAN rob
(4) ALP zer
RL 4 (2) PTY ele UP
460 RL 43290
5 (5) ACM smi
RL 43290
44.5
(7) FIC GI
(1) ROS pro (8) VIO ban
(5) COR hyb (4) COR hyb
29"
(9) BLE SL
(2) HIB Yel
(6) VIO ban
29'
DP DP
°
UP
(10) DOO asp
197
(5) NEO BN
RL 43290
(10) VIO ban
0
.5
.
42.5
269°56'38"
42
43 (10) FIC pum
(2) HIB Yel (3) PTY ele (20) LIR SW (2) ELA PD (2) RAN fit
Self-adhering climbers at foot of wall
2 0 3 7m
LEGEND 0
44.
PLANTING TURF SUNTHETIC CANOPY COLUMNAR FEATURE GROUND
SHRUBS
AREAS EXTENTS TURF TREES TREES SHRUBS COVERS SCALE 1:150
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 2 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP02 C
C SL 21/12/21 RFI RESPONSE scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP GROUND FLOOR PLANTING PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 2 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 5
PROPERTY BOUNDARY 33.544M | 89° 56' 36"
WC
(6) CRA RE STUDY
(8) SEN BC
SPIRAL STAIRS SOLID BALUSTRADE
PROPERTY BOUNDARY 15.091M | 359° 59' 36"
KITCHEN FW FW
SYN UN-ROOFED ARBOR STRUCTURE
OVER PROPOSED BBQ AREA
BALUSTRADE
POOL FENCE
SLAB EXTENSION
ROOFTOP TILES Refer Architect
TERRACE
SPA PRIVATE TOOFTOP TERRACE
VERTICAL BATTEN BALUSTRADE
LIFT
VERTICAL BATTEN SCREENS Tiled finish to Architect's Detail.
FW BBQ AREA FW
PROPERTY BOUNDARY 15.091M | 179° 58' 36"
SPIRAL STAIR CASES TO ROOFTOP FW BBQ AREA FW
LIFT
SPA
KITCHEN ROOFTOP
TERRACE
BALUSTRADE
(6) CRA RE POOL FENCE
(8) SEN BC TILES
STUDY
SYN
WC
LEVEL TWO (8) HIB Red
STORE (9) ROS pro
INSET PLAN FW FW
FW FW
(8) HIB Red
(9) ROS pro
NON-
TRAFFICABLE
AREA
CONTAINERIZED PLANTER
Max 1.2m high 150 Series blockwork requiring
waterproofing, irrigation and drainage connected SYN
BALUSTRADE
to stormwater system. Refer typical detail
POOL FENCE
TILES
LEVEL TWO PLANTER (REFER INSET PLAN) ROOFTOP
Max 1.2m high containerized planter requiring TERRACE
9"
SPA
29' 2
waterproofing, irrigation and drainage connected to LIFT
stormwater system. Refer typical detail
197°
FW BBQ AREA FW
M|
3.593
PROPOSED HOSECOCK LOCATIONS FW BBQ AREA FW
RY 1
Refer Hydraulic Engineer
NDA
LIFT
SPA
BOU
TILES
TY
ROOFTOP
DE
SELECT SYNTHETIC TURF
PER
STRA
TERRACE
PRO
Installed over podium slab to manufacturer's
BALU
POOL FENCE
PROPERTY BOUNDARY 16.098M | 359° 59' 36"
specification. Ensure falls towards podium
SYN
S
drainage inlets to eliminate ponding.
GLAS
FW FW
SOLID BALUSTRADE
PROPERTY BOUNDARY 29.463M | 269° 56' 38"
2 0 3 7m
LEGEND
CONTAINERIZED MASONRY WALL TILED FINISH SYNTHETIC GROUND
SHRUBS
PLANTERS MAX 1.2M HIGH REFER ARCHITECT TURF COVERS SCALE 1:150
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 3 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP03 C
C SL 21/12/21 RFI RESPONSE scale: 1:150 @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP ROOFTOP LANDSCAPE PLAN project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 3 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 6
NOTES:
100
TURF: GREEN COUCH OR WINTERGREEN MULCH: AS SPECIFIED 1. ALL TIMBER TO BE ACQ TREATED ROUGH SAWN APPEARANCE GRADE HWD OF
COUCH UNLESS OTHERWISE SPECIFIED. A SINGLE SPECIES.
ROLLED AND WATERED-IN AT PLANTING. 2. ALL TIMBER IN CONTACT WITH GROUND TO BE PRESERVATIVE TREATED TO
300
REFER SPECIFICATION NOTES TOPSOIL: SITE SOIL, IMPROVED SITE SOIL PLANT: AS SPECIFIED ON PLANS UNLESS HAZARD CLASS H5 TO AS 1604 & HAVE A DURABILITY CLASS 1 OR 2 TO AS 5604.
OR IMPORTED SOILMIX AS SPECIFIED DIRECTED AND APPROVED BY PROJECT 3. ALL TIMBER TO BE FREE OF KNOTS, CRACKS OR ANY MAJOR DEFECT.
100
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL LANDSCAPE ARCHITECT 4. TO FORM CURVES SAW CUT RELIEF TO EDGE TO PROMOTE EASE OF BENDING.
OR IMPORTED SOILMIX AS SPECIFIED STAKE AT CLOSER INTERVALS WHERE REQUIRED.
150
MAINTAIN MINIMUM 50mm SEPARATION
200
CULTIVATED SUBGRADE: RIP / CULTIVATE CULTIVATED SUBGRADE: RIP / CULTIVATE MULCH: AS 100X25mm TIMBER EDGE
BETWEEN MULCH AND STEM OF PLANT TO
EXISTING SUBGRADE AS SPECIFIED EXISTING SUBGRADE AS SPECIFIED SPECIFIED FIXED WITH 2 (MIN.)
ENSURE ADEQUATE AIR CIRCULATION
EXISTING SUBGRADE GARDEN PROFILE: GALVANISED NAILS PER
EXISTING SUBGRADE SLOW RELEASE FERILISER: AS SPECIFIED REFER TO DETAIL STAKE.
& SPECIFICATION FLUSH
25
NOTES: NOTES: TURF PROFILE: REFER
DETAIL & SPECIFICATION
Y
1. ENSURE PRIOR TO LAYING OF TURF THAT ALL FALLS ACROSS SLOPES HAVE 1. ALL UNDERGROUND SERVICES SHALL BE LOCATED AND CLEARLY MARKED
2Y
EVEN GRADE FALLS WITH NO BUMPS OR HOLLOWS. PRIOR TO GARDEN PREPARATION . ENSURE CAUTION WHEN CULTIVATING OVER
X TOPSOIL: AS SPECIFIED
2. ALL TURF SHALL BE LAID IN A STRETCHER BOND PATTERN (PARALLEL TO SERVICE LINES, PIPES AND AROUND EXISTING TREE ROOTS AND IF NECESSARY
CONTOURS ON SLOPES) AND EACH TURF SEGMENT FIRMLY CLOSE BUTTED. CULTIVATE USING HAND TOOLS. DO NOT CULTIVATE WITHIN 600mm OF PLANTING HOLE: OVER EXCAVATE HOLE BY
TURF SEGMENTS SHALL NOT BE STRETCHED TO FIT. PROPOSED OR EXISTING HARD PAVED AREAS OR STRUCTURES. TWICE THE WIDTH (2X) AND DEPTH (2Y) OF CULTIVATED SUBGRADE:
3. TURF TO BE LIGHTLY WATERED DURING THE INSTALLATION PROCESS AND BE 2. PROFILE THE EXISTING SUBGRADE TO ACHIEVE THE DESIRED F.S.L AND THE POT SIZE. CULTIVATE BASE OF HOLE AS SPECIFIED
MAINTAINED IN A MOIST CONDITION THROUGHOUT THE INSTALLATION PROCESS. DRAINAGE FALLS PRIOR TO APPLICATION OF TOPSOIL AT SPECIFIED DEPTH CULTIVATED SUBGRADE: RIP / CULTIVATE 350X50X50mm STAKES AT
4. ALL TURF SHALL FINISH FLUSH, AFTER TAMPING WITH ADJACENT FINISHED 3. WHERE EXISTING SITE TOPSOIL IS BEING REINSTATED A PRE-EMERGENT EXISTING SUBGRADE AS SPECIFIED 1000mm (MAX.) CENTRES.
SURFACE LEVELS AND BE EVENLY GRATED BETWEEN TURF SEGMENTS WITH NO HERBICIDE SHALL BE APPLIED DURING TOPSOIL INSTALLATION (ACCORDING TO EXISTING SUBGRADE
EXISTING SUBGRADE
VARIATION GREATER THAN +/- 10mm. MANUFACTURER'S SPECIFICATION)
5. TURF SHALL BE LIGHTLY ROLLED WITHIN 24 HRS OF INSTALLATION. 4. FINISH THE SURFACE LEVEL OF SOIL TO ALLOW 100mm DEPTH OF ORGANIC 2X 200 200
MULCH ENSURING MULCH F.S.L IN 25mm BELOW F.S.L OF ADJOINING SURFACES
01 TYPICAL TURF PROFILE 02 TYPICAL PLANTING AREA PROFILE 03 TYPICAL PLANTING DETAIL 04 TYPICAL TIMBER GARDEN EDGE
LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20 LP04 SCALE 1:20
BASIN: FORM AN EARTHEN BASIN AROUND
THE BASE OF THE PLANT TO HOLD WATER
NOTES
DRIP IRRIGATION: CONNECTED TO MULCH: FINISH MULCH LEVEL TO BE 25mm BELOW
TREE: AS SPECIFIED ON PLANS UNLESS 1. CHECK ALL STOCK ONCE REMOVED
NON-TOWN WATER SUPPLY TOP OF PLANTER. REFER SPECIFICATION NOTES
DIRECTED AND APPROVED BY PROJECT FROM POT TO ENSURE STOCK IS NOT
LANDSCAPE ARCHITECT ROOT BOUND. IF ROOTS ARE BOUND, UNDERSTOREY PLANTING: REFER PLANTER: BLOCK WALL. REFER
REJECT. PLANTING PALETTE STRUCTURAL ENGINEERS DETAIL
25
STAKES: 2 NO. HWD STAKES 1800X38X38mm 2. PLANTS TO BE HEALTHY AND
DRIVEN 600mm INTO GROUND. DO NOT VIGOROUS, TREES MUST HAVE A FERTILIZER: REFER
INTERNAL DEPTHS (MIN) FOR:
PENETRATE ROOTBALL. SINGLE TERMINAL SHOOT (UNLESS SPECIFICATION NOTES
200
GROUNDCOVERS 600mm
LARGE SHRUBS 800mm
100
SPECIES IS MULTI-STEMED) REFER WATERPROOF MEMBRANE:
SMALL SHRUBS AND
TIES: PROVIDE NON-ABRAISIVE,
TREES: 1200mm
SPECIFICATION. ENSURE NO INSECT REFER MANUFACTURER
NON-CUTTING MATERIAL TIES IN A FIGURE 8
DAMAGE.
PATTERN FIXED SECURELY TO STAKES PODIUM SOIL BLEND: REFER
3. STAKING OF TREES SHALL BE
MAINTAIN MINIMUM 50mm SEPARATION UNDERTAKEN AT THE TIME OF SPECIFICATION NOTES
MULCH: AS
BETWEEN MULCH AND STEM OF PLANT TO PLANTING. PLACE ONE STAKE ON THE
SPECIFIED ADJACENT SURFACES: REFER
ENSURE ADEQUATE AIR CIRCULATION WINDWARD SIDE OF THE TREE. PLANS AND SPECIFICATION
400
50
4. STAKES TO BE HARDWOOD, FREE
SLOW RELEASE FERILISER: AS SPECIFIED FROM KNOTS OR TWISTS AND
POINTED AT ONE END.
40
TOPSOIL: SITE SOIL, IMPROVED SITE SOIL OR
5. REMOVE ALL NURSERY STAKES AND
IMPORTED SOILMIX AS SPECIFIED. FORM
Y
BAMBOO STAKES FROM ALL TREES AT
SHALLOW DEPRESSION AROUND TOP OF
2Y
THE TIME OF PLANTING. PODIUM SLAB SAND: MINIMUM 50mm DEPTH
ROOTBALL TO IMPROVE WATER RETENTION
6. THOROUGHLY WATER THE TREES OF COARSE WASHED SAND.
PLANTING HOLE: OVER EXCAVATE HOLE BY X BEFORE PLANTING, IMMEDIATELY GEOTEXTILE: BIDUM FILTER LAYERS
TWICE THE WIDTH (2X) AND DEPTH (2Y) OF AFTER PLANTING AND AS REQUIRED INSTALLED TO MANUFACTURERS SPEC DRAINAGE CELL: VERSICELL DRAINAGE
THE POT SIZE. CULTIVATE SIDES AND BASE TO MAINTAIN GROWTH RATES FREE OF DRAINAGE: CONNECTION TO STORMWATER MODULES OR EQUIVALENT. INSTALL TO
OF HOLE EXISTING SUBGRADE STRESS THROUGHOUT THE PLANTING SYSTEM. REFER STRUCTURAL AND MANUFACTURER'S SPEC
ESTABLISHMENT PERIOD. HYDRAULIC ENGINEER'S DETAIL
2X WATERPROOF MEMBRANE:
REFER SPECIFICATION
05 TYPICAL ADVANCED TREE 06 TYPICAL CONTAINERIZED PLANTER DETAIL - ROOFTOP LEVEL
LP04 SCALE 1:40 LP04 SCALE 1:40
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 4 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP04 C
C SL 21/12/21 RFI RESPONSE scale: AS SHOWN @ A3 Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP TYPICAL LANDSCAPE DETAILS project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 4 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240
Section 7
PROJECT NAME CLIENT DRAWING purpose: COUNCIL APPROVAL sheet no: SHEET 5 OF 5
drawn: dwg no: issue:
phase: DETAILED DESIGN
SL 2000902-LP05 C
C SL 21/12/21 RFI RESPONSE scale:
- Use figured dimensions in preference to scale. All
B SL 08/10/21 COUNCIL APPROVAL 65-67 ELANDA ST SUNSHINE BEACH NULUXE PROPERTY GROUP PLANTING SCHEDULES project no:
20-00902 dimensions to be verified on site prior to construction.
PROPOSED MULTI-DWELLING DEVELOPMENT - SHEET 5 refer any discrepancies to project landscape architect.
A SL 10/09/21 CLIENT REVIEW date: DEC 2021
© Openspace Architecture 2021 abn 91 651 947 240