                    Site and Soil Evaluation
On-Site Wastewater and Effluent Disposal System Design



                        Tiny Home
              328 Upper Pinbarren Creek Road,
                    Pinbarren Qld 4568




                                                                           Report #           TE249167
                                                                            Issue                   A
                                                                            Date              6 Nov. 24




 OFFICES IN   BRISBANE, TOOWOOMBA, GOLD COAST, HERVEY BAY. SERVICING WIDER QUEENSLAND
Log in to download the original file

SSE - TE249167 - 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568.pdf · 3.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 17 pages

Page 2

1     Introduction
1.1       Background
Taylor Environmental (Australia) Pty Ltd was engaged to design a new on-site wastewater treatment
and effluent disposal system for the tiny home installed at 328 Upper Pinbarren Creek Road, Pinbarren
Qld 4568.

This property is not serviced by a municipal sewer network and requires all wastewater to be managed
on site. The purpose of this report is to design a domestic wastewater management system that meets
the requirements of AS1547 and the Queensland Plumbing and Wastewater Code.

1.2       Proposal
The tiny home, on a trailer next to the dams, has a composting toilet with leachate drain, with greywater
being disposed to land.

It is proposed to install a compliant wastewater management system consisting of:

      •    A partitioned septic tank for the greywater and small volume of composting liquid, with an
           advanced enviro septic bed (AES)


1.3       Scope of Works
The scope of works for this Site and Soil Evaluation are outlined below:

      •    Undertake a desktop study of the property, including a review of the development, sensitive
           environments, geology and slope
      •    Carry out a site inspection (31 October 2024)
      •    Investigate the receiving soil
      •    Determine a suitable location and method of effluent disposal
      •    Prepare plans for the wastewater management system for Council consideration


1.4       Legislation and Standards
This report has been completed in accordance with the relevant legislative requirements:

      •    Plumbing and Drainage Act
      •    Plumbing and Drainage Regulation
      •    Queensland Plumbing and Wastewater Code
      •    AS/NZS 1547:2012 On-site Domestic Wastewater Management
      •    AS1546.3:2017 Secondary Treatment Systems
      •    Plumbing Code of Australia (PCA)


1.5       Approvals
Before commencing the work, this Site and Soil Evaluation (Deemed to Satisfy) must be submitted and
approved by the local Council as Permit Work under the Plumbing and Drainage Regulation 2019.




Site and Soil Evaluation                                    328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                           Page 2 of 19

Page 3

2     Site and Soil Assessment
2.1      Property Details
Details of the subject property are presented in Table 1, below.

Table 1: Property Details
 Feature                                   Details
 Property Address                          328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
 Lot and Plan                              Lot 3 RP851976
 Local Authority                           Noosa Shire Council
 Property size                             25.63 ha
 Water Supply                              Reticulated water
 Zone                                      Rural
 Water Catchments                          Not located in a water catchment or buffer area

Figure 1 shows the subject property.




                                                                  Tiny Home




Figure 1: Subject Property




Site and Soil Evaluation                                                328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                                       Page 3 of 19

Page 4

2.2      Site Assessment
Table 2 outlines the site assessment for this development.

Table 2: Site Details
 Feature                                   Details
 Elevation                                 ≈130-135m AHD
 Slope                                     Levelled building area with upto 22% slope behind
 Slope configuration                       Linear planar
 Exposure                                  Good exposure
 Aspect                                    North to north west
 Permanent surface waters                  Several dams in the middle of the development area
 Intermittent surface waters               Drains/gullies linking dams
 Flood hazard                              n/a - no flood overlays present on the property
 Groundwater bores                         Groundwater bore near paddocks to the west
 Vegetation                                Mostly grassed, with few small trees remaining
 Environmental Areas                       n/a – wastewater system in grassed area

Figure 1 shows the tiny home. The wastewater system will be on the grassed hill behind.




Figure 2: Tiny Home




Site and Soil Evaluation                                                 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                                        Page 4 of 19

Page 5

2.3         Soil Investigation
The site and soil evaluation was undertaken on 31 October 2024, with earlier soil tests undertaken by
Global Testing in 2019. The soil profile and design characteristics for the effluent disposal area are
presented in Table 3.

Table 3: Soil Type
                                BH1                                                         BH2
                               Sandy Clay, Category 4                                     Sandy Clay, Category 4
      0 – 500                                                       0 – 500
                                   Low plasticity                                             Low plasticity
                               Sandy Clay, Red/brown                                      Sandy Clay, Red/brown
    500 – 1200                                                  500 – 1200
                                 Medium plasticity                                          Medium plasticity
        Ksat                          0.20 m/day                     Ksat                        0.22 m/day
                                                   Design Characteristics
    Receiving depth                           Basal area will be around 900mm deep
    Texture                                   Light Clay
    Structure                                 Strongly Structured
    Category                                  5
    Design Loading Rate (DLR)                 12 mm/day for secondary+ effluent




2.4         Habitable Buildings
This property has a number of habitable buildings with wastewater systems. Table 4 below online each
building and its number of Equivalent Persons in reference to the Environmental Protection Regulations
Equivalent Persons.

Table 4: Habitable Buildings
                                                                                                     ERA63 Equivalent
    Building                                   Bedrooms                AS1547 Persons1
                                                                                                        Persons2
    Tiny house                                     1 br                2 persons = 300L                     1.5 EP
    Vistor Accomodation #1                         1 br                2 persons = 300L                     1.5 EP
    Visitor Accommodation #2                       2 br                3 persons = 450L                     2.25 EP
    Visitor Accommodation #3
                                                   1 br                2 persons = 300L                     1.5 EP
    “Mango Tree Cabin”
    Caretakers                                     3 br                5 persons = 750L                     3.75 EP
    Granny Flat                                    2 br                3 persons = 450L                     2.25 EP
    Primary Residence                              3 br                5 persons = 750L                     3.75 EP
    Total                                          13 br              22 persons = 3300L                    16.5 EP




1
    Where 1 person = 150 L/day
2
    Where 1 Equivalent Person = 200 L/day
Site and Soil Evaluation                                               328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                                      Page 5 of 19

Page 6

3       Proposed Wastewater System
3.1       Proposed Wastewater System
It is proposed to relace the composing tank leachate drain and the greywater disposal with a partitioned
septic tank and advanced enviro septic (AES) bed. A 10m setback is required to the surface waters, and
as such a pump is required in the second chamber of the septic tank.


3.2       Design Details
Table 4 below presents the features of the proposed wastewater system.

Table 5: Design Features
                                Feature                           Details
                                Water supply                      Rain water / bore water
                                Volume Allowance                  1503 L/person/day
       Design Volume            Number of bedrooms                1
                                Design population                 2
                                Total Design Volume (Q)           300 L/day
                                Category                          5
     Soil Characteristics
                                Design Loading Rate (DLR)         12 mm/day
                                Septic tank capacity              3000 L (min) partitioned tank, with pump
                                Treatment facility                Advanced Enviro Septic (AES)
     Treatment System
                                Treatment plant approval          06 - 2024
                                Treatment level                   Advanced secondary
                                Required disposal area            A = Q/DLR = 25 m2
        Disposal Area           Footprint as per
                                                                  12.9m x 1.94m = 25 m2
                                AES Design Calculator

The design of the AES system is presented in Appendix A.
The Advanced Enviro-Septic Approved Design Calculator is presented in Appendix B.
The AES Treatment Plant Approval is presented in Appendix C.

General requirements and notes
   • 100% reserve area to be kept clear of permanent structures
   • Deep rip base of beds and spread gypsum at 1kg/m2
   • Grass is to be established in the land application area, and mown regularly
   • Stormwater should not traverse the land application area. Construct a stormwater diversion
        upslope
   • General access to the land application area by pedestrians, vehicles and animals is to be
        generally excluded
   • Install at least 2x ‘effluent reuse’ warning signs around land application area
   • The system is to be installed, operated and serviced in accordance with manufacture
        specifications
   • The land application area has been designed based on a daily wastewater volume in accordance
        with AS1547. Any exceedance of this design volume may have adverse effects on the land
        application area




3
    Conservative volume allowance, as composting toilets have very low discharge volumes
Site and Soil Evaluation                                               328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                                      Page 6 of 19

Page 7

3.3      Effluent Quality
Table 5 below presents the effluent standards produced by approved wastewater treatment systems
with subsurface disposal, as per AS1546.3:2017 Secondary Treatment Systems.
Table 6: Effluent Quality
                                                     Secondary Effluent                 Advanced Secondary Effluent
                 Parameter
                                              90% of samples          Maximum           90% of samples           Maximum
                     BOD5                        < 20 mg/L             30 mg/L             < 10 mg/L              20 mg/L
                      TSS                        < 30 mg/L             45 mg/L             < 10 mg/L              20 mg/L

The proposed treatment plant has approvals for Advanced Secondary effluent.


3.4      Setback Distances
The Queensland Plumbing and Wastewater Code V1:2024 Appendix 1 outlines minimum setback
separation distances required for onsite wastewater management facilities. This design complies with
the relevant setbacks.

The ‘Land Application Area Setback Distances’ (QPWC Table T2) are presented in Table 6.

Table 7: Separation Distances: Subsurface land application areas
                                                                                      Separation Distance
                                 Feature
                                                                           Upslope           Downslope              Level
 Property boundaries, pedestrian paths, walkways,
 recreation areas, retaining wall, and footings for buildings                2m                  4m                 2m
 and other structures
 Inground swimming pools                                                     6m                  6m                 6m
 Inground potable water tank not exposed to primary
                                                                             6m                  6m                 6m
 effluent
 Inground potable water tank exposed to primary effluent                     15 m               15 m                15 m
*Distances are given in meters and are measured from the edge of trench/bed excavation or subsurface irrigation distribution
pipework to the nearest point of the feature

The ‘Protection of Surface Water and Groundwater Setback Distances’ (QPWC Table T5) are presented
in Table 7.

Table 8: Separation Distances: Protection of Surface Water and Groundwater
                                 Feature                                              Separation Distance
 Effluent Quality                                                         Adv. Sec.         Secondary            Primary
 Top of bank of permanent water course                                      10 m               30 m                50m
 Top of bank of intermittent water course                                   10 m               30 m                50m
 Top of bank of a lake, bay or estuary                                      10 m               30 m                50m
 Top water level of a surface water source used for
                                                                            10 m               30 m                50m
 agriculture, aquaculture or stock purposes
 Open stormwater drainage channel or drain                                  10 m               30 m                50m
 Bore or dam                                                                10 m               30 m                50m
 Unsaturated depth to a permanent water table (vertical)                    0.3 m              0.6 m               1.2m
*Distances are given in meters and are measured from,
         - any part of the on-site sewage facility (including pipes and fittings) and,
         - the edge of irrigated wetted area of the Land Application Area to the feature as listed.



Site and Soil Evaluation                                                 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                                        Page 7 of 19

Page 8

4     Maintenance

Property owners have a responsibility to ensure the onsite wastewater treatment and effluent disposal
system is maintained and serviced. The following servicing and precautions are to be undertaken:

     •     Septic tanks to be checked annually and pumped out when 1/3 full of solids or once every 5
           years, whichever is sooner
     •     Read and follow the Owner's Manual that is provided with the system
     •     Comply with local authority’s servicing requirements
     •     Do not manipulate the system so that it no longer complies with the Council issued permit or
           the plans located in Appendix A of this document
     •     Maintain the land application area e.g. regularly mowed and ensure that there is no ponding
           of effluent
     •     Vehicles, animals and general access to the land application area is to be generally restricted
           with warning signs erected
     •     Use low sodium biodegradable soaps and detergents as per the label instructions and no paints,
           solvents, chemicals, food scraps, fats, oils or any other solids to be disposed of “down the drain”
     •     It is always good practice to minimise / stagger high wastewater generating activities such as
           laundry over a full week
     •     On-site sewage systems are not designed to cope with the flow from garbage grinders


The design was completed by Chris Taylor (Director, Taylor Environmental (Australia) Pty Ltd, QBCC
Licence Number 150 556 72).



Chris Taylor MEnvMan, BAppSc(Chem), ADCivEng Cert IV DWM003
Director | Taylor Environmental (Australia) Pty Ltd
6 Nov. 24




Site and Soil Evaluation                                        328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                                               Page 8 of 19

Page 9

Appendix A Design Drawings




Site and Soil Evaluation                   328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                          Page 9 of 19

Page 10

PROJECT:
                                                                                                                                                                                                         REVISIONS
ONSITE WASTEWATER TREATMENT AND EFFLUENT DISPOSAL SYSTEM                                                                                                                                  #
                                                                                                                                                                                          A
                                                                                                                                                                                               DATE       SUBJECT
                                                                                                                                                                                               06/11/2024 REVISION A
                                                                                                                                                                                                                            AUTHORISED
                                                                                                                                                                                                                            C. TAYLOR


FOR TINY HOME AT 328 UPPER PINBARREN CREEK ROAD, PINBARREN

GENERAL NOTES                                                                      LEGEND
 1. LOCATION OF HSTP, ORG, VENT PIPE AND OTHER WASTE PIPES TO BE DETERMINED BY                     PROPERTY BOUNDARY                                                                          TAYLOR ENVIRONMENTAL
     PLUMBER                                                                                       EASEMENT
 2. REFER TO COMPLIANCE PERMIT FOR CONDITIONS OF COUNCIL APPROVAL                                  CONTOUR - MINOR
 3. PROPERTY FEATURES, STRUCTURES AND CONTOURS HAVE BEEN REPRODUCED BASED ON                       CONTOUR - MAJOR
     THE BEST AVAILABLE INFORMATION AND MAY NOT BE COMPLETE OR ACCURATE                            DECOMMISSION
 4. THE SYSTEM INSTALLER IS RESPONSIBLE TO ESTABLISH THE LOCATION, LEVELS AND
     DEPTHS OF ALL EXISTING SERVICES ON-SITE PRIOR TO COMMENCING ANY WORKS                         MSES VEGETATION
 5. LOCATIONS AND SETOUT DIMENSIONS SHOWN ARE APPROXIMATE ONLY AND ARE TO BE                       VEGETATION LINE
     CONFIRMED ON SITE.                                                                            TREE LINE
 6. ACCESS AND LAY DOWN AREAS ARE TO BE CONFIRMED BY THE SYSTEM INSTALLER                          PROTECTED TREE
 7. EXISTING BUILDINGS AND EXTERNAL STRUCTURES SHOWN ON THESE DRAWINGS ARE                         INTERMITTENT WATERBODY
     OBTAINED FROM THE AVAILABLE INFORMATION AND MAY NOT BE COMPLETE AND                           PERMANENT WATERBODY
     ACCURATE                                                                                      FLOW PATH
 8. ALL DIMENSIONS ARE IN MM U.N.O                                                                 DEFINED FLOOD LINE
 9. PLUMBING AND DRAINAGE TO QLD PLUMBING & WASTEWATER ACT, AS / NZS 3500                          CHANGE OF GRADE
 10. ALL PIPE WORK TO AS / NZS 4020                                                                TOP OF BANK
 11. ALL TANKS TO BE INSTALLED AND ANCHORED IN COMPLIANCE WITH THE                                 RETAINING WALL
     MANUFACTURERS SPECIFICATIONS
 12. FLEXIBLE JOINTS ON ALL INSTALLED TANKS (AS / NZS 3500)                                        WASTEWATER COMPONENT
 13. THERE SHALL BE NO CROSS CONNECTION BETWEEN ANY WASTEWATER / EFFLUENT                          GRAVITY DRAINAGE - NEW
     PIPEWORK AND ANY POTABLE WATER SUPPLY PIPEWORK                                                GRAVITY DRAINAGE - EXISTING
 14. MINIMUM DISTANCE BETWEEN TANKS AND BUILDINGS TO BE MAINTAINED (AS/NZS 3500)                   RISING MAIN - NEW
 15. USE ONLY A LICENSED DRAINER THAT HAS BEEN ACCREDITED BY THE SYSTEM                            RISING MAIN - EXISTING
     SUPPLIER.
 16. FINAL LOCATION OF THE LAND APPLICATION AREA AND ASSOCIATED PIPE WORK CAN                      STORMWATER PIPE
     ONLY BE ALTERED ON SITE TO MEET THE SITE CONDITIONS AFTER APPROVAL FROM                       WATER MAINS
     TAYLOR ENVIRONMENTAL (AUSTRALIA) PTY LTD                                                      ELECTRICAL - OVER HEAD
                                                                                                                                                                                                QBCC LICENCE NUMBER 150 556 72
 17. GRADE ALL BATTERS EVENLY AT 1 IN 5, UNLESS NOTED OTHERWISE                                    ELECTRICAL - UNDERGROUND                                                                        ABN NUMBER 95268308955
 18. ANY SOILS ENCOUNTERED WHICH SHOW EVIDENCE OF CONTAMINATION ARE TO BE                          COMMS SERVICES
     STOCKPILED SEPARATELY. CONTAMINATED SOIL SHALL BE HANDLED IN ACCORDANCE                       NBN SERVICES
     WITH ALL WORKPLACE HEALTH & SAFETY AND ENVIRONMENTAL REGULATIONS                              TELSTRA SERVICES
                                                                                                                                                                                                     Phone: +61 400 301 364
 19. IT IS THE INSTALLERS RESPONSIBILITY TO PROVIDE ACCURATE 'AS CONSTRUCTED'                      GAS SERVICES                                                                                  Email: [email protected]
     DRAWINGS TO RELEVANT LOCAL AUTHORITY AND INCUR ASSOCIATED COST                                FIRE MAIN SERVICES                                                                             Web: www.taylorenviro.com.au
 20. ALL DISTURBED AREAS TO BE REINSTATED TO NATURAL GROUND CONDITIONS
 21. EXISTING TOPSOIL IS TO BE RETAINED AND SET ASIDE (WINDROWED) TO PREVENT
     DAMAGE FROM MACHINERY AND REDISTRIBUTED ONCE INSTALLATION IS COMPLETE
 22. AT LEAST A 5 TONNE MACHINE WITH POSI-TRACK SYSTEM IS REQUIRED FOR             ABBREVIATIONS
     EARTHWORKS TO ELIMINATE POTENTIAL TRACK INDENTATIONS INTO GROUND LEVEL
 23. ALL MATERIALS SHALL BE NEW, PROVEN IN SERVICE AND SUITABLE FOR THE INTENDED   AAV       AIR ADMITTANCE VALVE
     USE                                                                           AES       ADVANCED ENVIRO SEPTIC OSSF SYSTEM
 24. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENGAGE THE DESIGNER TO           AS
                                                                                   B
                                                                                             AUSTRALIAN STANDARD
                                                                                             HAND BASIN                           PIN                                                     WASTE WATER TREATMENT &
     UNDERTAKE INSPECTIONS DURING INSTALLATION. FAILURE TO DO SO WILL RESULT IN                                                       BARR
     THE FORM 8 / COMMISSIONING CERTIFICATE NOT BEING ABLE TO BE COMPLETED         BTH
                                                                                   COS
                                                                                             BATH TUB
                                                                                             CLEAR OUT TO SURFACE                            EN                                           EFFLUENT DISPOSAL SYSTEM
 25. DO NOT SCALE FROM DRAWINGS                                                                                                                   CRE
 26. TAYLOR ENVIRONMENTAL TAKES NO RESPONSIBILITY FOR WORKS UNDERTAKEN BY THE      CS        CLEANERS SINK                                              EK
     INSTALLER AND/OR INSTALLATIONS THAT ARE NOT IN ACCORDANCE WITH THESE PLANS    DG        DISCONNECTOR GULLY
 27. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH THE SITE AND SOIL REPORT,      DW        DISHWASHER                                                                                   AUTHORISED FOR ISSUE             DATE
     ARTICULATED JOINT DESIGN AND REGULATOR ISSUED COMPLIANCE PERMITS              e??       EXISTING ITEM
                                                                                   FFL       FINISHED FLOOR LEVEL
                                                                                   FSL       FINISHED SURFACE LEVEL               UP
SANITARY DRAINAGE AND PLUMBING                                                                                                       PE                                                                                   06/11/2024
 1. SANITARY DRAINAGE SHALL BE ∅100 UPVC AT A 1:60 MINIMUM GRADE                   FWG       FLOOR WASTE GRATE                          R   PIN
 2. IO's UNDER CONCRETE/IMPERMEABLE GROUND COVERINGS SHALL BE TAKE TO SURFACE      HSTP      HOME SEWAGE TREATMENT PLANT                       BA
     LEVEL AS AN IOS AND FITTED WITH AN APPROVED SCREW CAP                         IL        INVERT LEVEL                                         RR                                      STREET ADDRESS
 3. ORG' RISERS SHALL BE TO AS3500.2 AND EXTEND TO AN APPROVED GRATE AT 150mm      IO        INSPECTION OPENING                                      EN
                                                                                   IOS       INSPECTION OPENING TO SURFACE                              C    RE                           328 UPPER PINBARREN CREEK RD, PINBARREN
     BELOW LOWEST FIXTURE, 75mm ABOVE GROUND LEVEL AND ABOVE DEFINED FLOOD                                                                                      EK
                                                                                   IV        INDEXING VALVE
     LEVEL
                                                                                   LAA       LAND APPLICATION AREA
                                                                                                                                                                     RO                   LOT & PLAN
 4. UNDERSLAB SANITARY DRAINAGE SHALL BE INSTALLED IN ACCORDANCE WITH THE                                                                                              AD
                                                                                   LT        LAUNDRY TUB
     ARTICULATED JOINT DESIGN (WHERE REQUIRED) AND AS3500.2 APPENDIX G
                                                                                   NGL       NATURAL GROUND LEVEL                                                                         LOT 3 RP851976
 5. LAGGING IN ACCORDANCE WITH AS3500
                                                                                   ORG       OVERFLOW RELIEF GULLY
 6. BURIED PIPEWORK SHALL BE 200mm DEEP IN NON TRAFFICABLE AREAS AND 500mm
                                                                                   OSSF      ON-SITE SEWAGE FACILITY
                                                                                                                                                                                          COUNCIL
     DEEP IN TRAFFICABLE AREA, OR IN ACCORDANCE WITH AS3500
                                                                                   RL        REDUCED LEVEL                                                                                NOOSA SHIRE
INSTALLATION                                                                       S         SINK
  1. IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE THAT ALL COMPONENTS COMPLY      SHR       SHOWER                                                                                       NAME OF CLIENT
      WITH THESE GUIDES UPON COMMISSIONING OF THIS SYSTEM                          ST        STACK
  2. ALL BURIED PIPE WORK IS TO BE IDENTIFIED WITH UNDERGROUND MARKING TAPE        UR        URINAL                                                                                       VIKI DIOSZOGI
      PLACED ABOVE THE PIPE WORK                                                   V         VENT
                                                                                   WC        WATER CLOSET                                                                                 DESIGNER
  3. ALONG THE BOUNDARY OF THE LAND APPLICATION AREA THERE SHALL BE AT LEAST 2
      WARNING SIGNS CLEARLY VISIBLE TO ADVISE THAT RECYCLED WATER IS USED (EACH                                                                                                           C. TAYLOR
      SIGN SHALL COMPLY WITH AS1319 AND HAVE THE WORDING RECYCLED WATER - AVOID
      CONTACT DO NOT DRINK)                                                                                                                                                               DRAWN
MAINTENANCE                                                                                                                                                                               M. MAHONY
 1. SYSTEM TO BE SERVICED AND MAINTAINED IN ACCORDANCE WITH MANUFACTURE
                                                                                                                                                                                          DRAWING DETAILS
     SPECIFICATIONS AND COUNCIL GUIDELINES
 2. SEPTIC TANKS TO BE CHECKED FOR SOLIDS BUILD UP ANNUALLY                                                                                                           SUBJECT PROPERTY    TITLE PAGE
 3. SEPTIC TANKS TO PUMPED OUT IF 31 FULL OF SOLIDS OR 5 YEARS (WHICHEVER IS
     SOONER)                                                                                                                                                                1:7500 @ A3   JOB NUMBER
 4. LAND APPLICATION IS IMPORTANT AND IS TO BE REGULARLY MOWED AND ANIMALS
     AND VEHICLES EXCLUDED                                                                                                                                                                TE249167
                                                                                                                                                                                              SCALE         REVISION          DWG #
                                                                                                                                                                                              1:7500            A              SL0

Page 11

                                                                                                                                                                                              FOR VISUALISATION ONLY.
                                                                                                                                                                                            REFER TO DETAILED PLAN FOR
                                                                                                                                                                                                  SYSTEM DETAILS                           REVISIONS
                                                                                                                                                                                                                            #    DATE       SUBJECT           AUTHORISED




                                                                                                                                                                                       AT
                                                                                                                                                                                    FL
                                                                                                                                                                                                                            A    06/11/2024 REVISION A        C. TAYLOR




                                                                                                                                                                                   NY
                                                                                                                                                                                 AN
                                                                                                                                                                               GR
                                                                                                                                                                           &
                                                                                                                                                                         BIN
                                                                                                                                                                     CA
                                                                                                                                                                    TO
                         TO PR


                                                                                                                                                                                                                                TAYLOR ENVIRONMENTAL
                               IMARY



                                                                                                         APPROVED UNDER MCU19/0053
                                                                                                                                                                                                                     FA
                                                                                                                                                                                                                    SH RM
                                     R
                                 ESIDEN




                                                                       APPROVED UNDER                                                                                                                                 ED
                                                                       MCU20/0084                                                  3br                  SHED
                                                                                                                                  CARE
                                     CE




                                                                                                                                 TAKERS
                                                                  R                                                               UNIT
                                                              ITO
                                                           VIS M. #2                                                                              ORIGINAL SEPTIC
                                                               O
                                                           ACC (2br)                                                                              AND GREYWATER
                                                R
                                             ITO 1                                                                                                SYSTEMS
                                          VIS M. #
                                              O
                                          ACC (1br)
                                                                                                                                                                     DAM


                                                                                                                                                                                                                                  QBCC LICENCE NUMBER 150 556 72
                                                                                                                                                                                                                                     ABN NUMBER 95268308955

                                                                                                                                                                                                                                       Phone: +61 400 301 364
                                                                 SEPTIC TANK AND AES                                                                                                                                               Email: [email protected]
                                                                 BED APPROVED UNDER                                                                                                                                                 Web: www.taylorenviro.com.au
                                                 AES BE
                                                       D         MCU20/0084




                                                                                        DAM                                                                                                                                 WASTE WATER TREATMENT &
                                                                                                                                                                                                                            EFFLUENT DISPOSAL SYSTEM


                                                                                                                265
                                                                                                                                       10m SURFACE



                                                                                                                 00
                                                                                                                                       WATER SETBACK
                                                                                                                                                                                                                            AUTHORISED FOR ISSUE             DATE
                                                                                                        24000
                                                                                                                                                                                                                                                            06/11/2024
                                   BORE
                                                                                               HOM NY




                                                                                                                                                                                                                            STREET ADDRESS
                                                                                                   E
                                                                                                  TI




               STABLES
                                                                                                                                                                                                                            328 UPPER PINBARREN CREEK RD, PINBARREN
                                                                                              1br




                                                                                                                                                                                                                            LOT & PLAN
                                                                                                                                                                                                                            LOT 3 RP851976
                                                                                                                                                                                                                            COUNCIL
                                                                                                                          PROPOSED SEPTIC TANK (WITH                                                                        NOOSA SHIRE
                                                                                                                          PUMP) AND AES WASTEWATER                                                                          NAME OF CLIENT
                                                                                                                          BED FOR GREYWATER &
                                                                                                                                                                                                                            VIKI DIOSZOGI
                                                                          STABLES




                                                                                                                          COMPOSTING TOILET LEACHATE
                                                                                                                                                                                                                            DESIGNER
                                                                                                                                                                                                                            C. TAYLOR
                                                                                                                                                                                                                            DRAWN
                                                                      S                                                                                                                                                     M. MAHONY
                                                                   BLE
                                                               STA                                                                                                                                                          DRAWING DETAILS
                                                                                                                                                                                                                            SITE LAYOUT
                                                                                                                                                                                                                            JOB NUMBER
                                                                                                                                                                                                                            TE249167
SITE LAYOUT                                                                                                                                                                                                                     SCALE         REVISION          DWG #
  1:750 @ A3                                                                                                                                                                                                                    1:750             A              SL1

Page 12

 NOTE: THE AES SYSTEM TREATMENT PLANT                                                                                                                                                           GENERAL NOTES:
   APPROVAL (TPA) 06-2024 LAPSES ON 1                                                                                                                                                            - LOCATION OF HSTP, ORG, VENT PIPE AND OTHER
    JANUARY 2024. THIS DESIGN MUST BE                                                                                                                                                               WASTE PIPES TO BE DETERMINED BY PLUMBER
INSTALLED PRIOR TO THIS DATE, OTHERWISE                                                                                                                                                          - REFER TO COMPLIANCE PERMIT FOR CONDITIONS OF
  A COUNCIL AMENDMENT MAY BE REQUIRED                                                                                                                                                               COUNCIL APPROVAL                                             REVISIONS
                                                                                                                                                                                                SEPTIC TANK / PUMPWELL:                           #    DATE       SUBJECT           AUTHORISED
                                                                                                                                                                                                 - TO BE INSTALLED AS PER MANUFACTURERS           A    06/11/2024 REVISION A        C. TAYLOR
                                                                                                                                                                                                    SPECIFICATION
                                                                                                                                                                                                 - SWIVEL KNUCKLE AND EXPANSION JOINTS TO BE
                                                                                                                                                                                                    INSTALLED ON INLET PIPE
                                                                                                                                                                                                 - SUBMERSIBLE TRANSFER PUMP WITH PUMP
                                                                                                                                                                                                    FAILURE ALARM
                                                                                                                                                                                                 - VENTING AS PER AS3500.2 SECTION 12.6.3

                                                                                                                                                                                                AES SYSTEM:
                                                                                                                                                                                                 - TO BE INSTALLED AS PER MANUFACTURERS
                                                                                                                                                                                                    SPECIFICATIONS AND BY A SUPPLIER APPROVED
                                                                                                                                                                                                    PERSON
                                                                                                                                                                                                 - DEEP RIP BASE OF BED AND SPREAD GYPSUM AT
                                                                                                                                                                                                    1kg/m2                                            TAYLOR ENVIRONMENTAL
                                                                                            PROPOSED PARTITIONED SEPTIC TANK FOR GREYWATER                                                       - 150mm MIN TOPSOIL OVER AES SAND BED
                                                                                                                                                                                                 - GRASS/TURF OVER BED
                                                                                             · 3000L (MINIMUM) CAPACITY                                                                          - NO TREES WITHIN 2m OF BED
                                                                                             · EG: EVERHARD POLY 3000L #87003 SIMILAR                                                            - 3m HIGH VENT AND VELOCITY REDUCER REQUIRED
                                                                                             · EXACT LOCATION TO BE CONFIRMED BY INSTALLER                                                          FOR PUMPED DELIVERY
                                                                                             · INSTALL SUBMERSIBLE TRANSFER PUMP IN SECOND
                                                                                                CHAMBER:
                                            APPROX LOCATION OF LEACHATE                         ·· DAVEY D25VA (OR EQUIVALENT) WITH DUTY
                                                 DRAIN TO BE ABANDONED                              OF 40 L/MIN @ 10m HEAD
                                                                                                ·· PUMP FAILURE ALARM
                                                                                                ·· VENTING AS PER AS3500.2 SECTION 12.6.3
                                                COMPOSTING TOILET TANK
                                            (CLIVUS MULTRUM). RE-DIRECT
                                          LEACHATE TO NEW SEPTIC TANK
                                                                                                                             1940

                                                                                                15000                                                              22%
                                                                                                                                                                         SLO
                        DAM                                                                                                                                                 PE

                                                                                                                                                                                                                                                        QBCC LICENCE NUMBER 150 556 72
                                                                      E




                                                                                                                                         RESERVE AREA
                                                                  HOM




                                                                                                                                                                                                                                                           ABN NUMBER 95268308955
                                                             TINY




                                                                                                                                                                                                                                                             Phone: +61 400 301 364
                                                                                                                                                                                                                                                         Email: [email protected]
                                                            1br




                                                                                                                                                                                                                                                          Web: www.taylorenviro.com.au




                                                                                                                     12900
                                                                                                                                                                                                                                                  WASTE WATER TREATMENT &
                                                                                                                                                                                                                                                  EFFLUENT DISPOSAL SYSTEM




                                                                                                                                        200
                                                                          APPROX CUT BANK                                                                        INSTALL 1m LONG VELOCITY                                                         AUTHORISED FOR ISSUE             DATE




                                                                                                                                            0
                                                                                                                                                                 REDUCER AND 3m TALL 'HIGH
                                                                                                                                                                 VENT' AT DELIVERY POINT                                                                                          06/11/2024

                                                                                                                                                                                                                                                  STREET ADDRESS
                                                                                                                                                                                                                                                  328 UPPER PINBARREN CREEK RD, PINBARREN
                                                                                                                                             LAND APPLICATION AREA                                                                                LOT & PLAN
                                                                                                                                              · AES BED [TPA 06-2024]                                                                             LOT 3 RP851976
                                                                                                                                              · 12.9m LONG x 1.94m WIDE = 22m²                                                                    COUNCIL
                                                                                                                                              · 1 ROW OF 4 AES PIPES
                                                                                                                                              · CURVE AROUND SLOPE AS REQUIRED                                                                    NOOSA SHIRE
                                                                                                                                              · ESTABLISH GRASS OVER FINISHED BED. TO BE MOWN                                                     NAME OF CLIENT
                                                                                                                                                 REGULARLY BY HOMEOWNER                                                                           VIKI DIOSZOGI
                                                                                                                                              · NO TREES PERMITTED WITHIN 2m OF BED
                                                                                                                                              · DRIVING OVER LAND APPLICATION AREA TO BE                                                          DESIGNER
                                                                                                                                                 GENERALLY AVOIDED. DO NOT PARK ON THE BED                                                        C. TAYLOR
                                                                                                                                              · STORMWATER TO BE DIVERTED AWAY FROM BED
                                                                                                                                                                                                                                                  DRAWN
                                                                                                                                              · THIS LAND APPLICATION AREA IS DESIGNED FOR A
                                                                                                                                                 MAXIMUM HYDRAULIC LOADING OF 300L/DAY                                                            M. MAHONY
                                                                                                                                              · 100% RESERVE AREA TO BE LEFT CLEAR OF                                                             DRAWING DETAILS
                                                                                                                                                 PERMANENT STRUCTURES
                                                                                                                                RISING MAIN                                                                                                       PROPOSED WORKS
                                                                                                                                  · ∅32od ∅26id PN12.5 LILAC
                                                                                                                                                                                                                                                  JOB NUMBER
                                                                                                                                     COLOURED POLYETHYLENE
                                                                                                                                  · INDICATIVE ALIGNMENT SHOWN                                                                                    TE249167
PROPOSED WORKS                                                                                                                    · BURY PER AS3500.1                                                                                                 SCALE         REVISION          DWG #
            1:200 @ A3                                                                                                                                                                                                                                1:200             A              SL2

Page 13

                             SOIL CHARACTERISTICS

                                  0 - 300 LOW PLASTICITY SANDY CLAY LOAM
   SOIL PROFILE AT BH1
                                  300 - 1200 MEDIUM PLASTICITY SANDY CLAY                                                                                                                                                                                                                                                                                      REVISIONS
                                                                                                                  3m HIGH VENT. ATTACH TO
                                                                                                                  BOLLARD FOR SUPPORT                                                                                                                                                                                                            #    DATE       SUBJECT          AUTHORISED
                                           CLAY LOAM AT 900 DEEP
      RECEIVING SOIL                                                                                                                                                                                                                                                                                                                             A    06/11/2024 REVISION A       C. TAYLOR
                                              (AES BASAL AREA)
                                                                                                                           OFFSET ADAPTER                                 COUPLING                                            STRAIGHT RAISED CONNECTOR                                                               ∅100 LOW VENT
       STRUCTURE                            STRONGLY STRUCTURED                         ∅100 uPVC
                                                                                 VELOCITY REDUCER
     SOIL CATEGORY                                      5                            [1m LONG MIN]




                                                                                                                                                                                                                                                                                                                             900
   PERMEABILITY (KSAT)                          0.12 - 0.5 m/DAY

   DESIGN LOADING RATE                              12 mm/DAY               ∅32OD ∅26ID PN12.5




                                                                                                                                                                                                                                                                                                                                    1940
                                DESIGN VOLUME
                                                                            LILAC COATED PIPE                                                                                                                                                                                                 INSPECTION POINT




                                                                                                                                                                                                                                                                                                                             1040
                                                                                                                                                 3m LONG ∅300 AES PIPE
     WATER SUPPLY                         RAIN WATER & BORE WATER                                                                                1 ROW OF 4 PIPES                                                            INSPECTION POINT
                                               150 L/P/DAY                                                                                                                                                                                                                                                                                           TAYLOR ENVIRONMENTAL
   VOLUME ALLOWANCE              (CONSERVATIVE ALLOWANCE WITH COMPOSTING
                                                  TOILET)                                                  300                                                     6000                                            300                                                    6000                                         300
  NUMBER OF BEDROOMS                               LOFT BEDROOM
                                                                                                                                                                                                                 12900
    DESIGN POPULATION                               2 PERSONS

  TOTAL DESIGN VOLUME                               300 L/DAY

                                 TREATMENT                                                                                                                                            AES BED PLAN VIEW                                                                                   AES BED CONSTRUCTION:
                                                                                                                                                                                                                                                                                           - TO BE INSTALLED AS PER MANUFACTURERS
  SEPTIC TANK CAPACITY                               3000L MIN                                                                                                                                                                                                                                SPECIFICATIONS AND BY A SUPPLIER APPROVED PERSON
                                                                                                                                                                                                                                                                                           - EXCAVATE WITH LASER LEVEL
                                        ADVANCED ENVIRO SEPTIC (AES)                                                                                                                                                                                                                       - RIP LEVEL OF BASE ≈200 to 300mm
    TYPE OF FACILITY
                                              MODEL: 30L/MIN                                                                                                                                                                                                                               - RE-EXCAVATE BACK TO CORRECT LEVEL USING A LASER
                                                                                                                                                                                                                                                                                              LEVEL
    TREATMENT LEVEL                          ADVANCED SECONDARY                                                                                                                                                                                                                            - GYPSUM BASE AT 1kg/m2
                                                  06 - 2024                                                                                                                                                                                                                                - PLACE AES APPROVED SAND TO SPECIFIED DEPTH
           TPA                                                                                                                                                                                                                                                                                UNDER PIPES
                                             (LAPSES 1 JAN 2025)




                                                                                                                                                                                                      MIN 3m
                                                                                                                                                              ∅100 HIGH VENT                                                                                                               - PLACE AES PIPES AND CONNECTORS, ENSURING THEY
                               DISPOSAL AREA                                                                                                                                                                                                                                                  ARE LEVEL ACROSS THE ENTIRE LENGTH
                                                                                                                                                                                                                                                                                           - PLACE AES APPROVED SAND TO SPECIFIED DEPTH
MINIMUM AES AREA REQUIRED                       A = Q/DLR = 25m²                                                                                                                                                                                                                              OVER PIPES
                                                                                                                                                                                                                INSPECTION POINT                                                           - REPLACE EXCAVATED TOP SOIL TO A MINIMUM DEPTH             QBCC LICENCE NUMBER 150 556 72
  AES FOOTPRINT AS PER                                                                                                                                                                                                              BACK FILL MOUND OVER AES                                  OF 150mm                                                    ABN NUMBER 95268308955
                                             12.9m x 1.94m = 22 m²                                                                                                                                                                                                                         - ESTABLISH GRASS TO PROMOTE EVAPOTRANSPIRATION
 AES DESIGN CALCULATOR
                                                                                                                                 STORMWATER                                                                                                                                                - NO TREES WITHIN 2m OF BED
NUMBER OF AES PIPE ROWS                               1 ROWS                                                                        DIVERSION                                                                                        APPROVED SAND                                                                                                         Phone: +61 400 301 364
                                                                                                                                                               ∅100 LOW VENT                                                                                                                                                                           Email: [email protected]




                                                                                                                                                                                                                150 MIN
NUMBER OF AES PIPES/ROW                            4 PIPES/ROW                                                                                                                                                                             GRASS                                                                                                        Web: www.taylorenviro.com.au
    BUFFER CAPACITY                                   869 L                                                                                                                                                                                             INSPECTION POINT
                              BILL OF QUANTITIES




                                                                                                                                                                                       150




                                                                                                                                                                                                                                                                150 MIN
        AES PIPES                                       4
                                                                                                                                                                                     300               300
                                                                                                                                                                                                                                                                                                                                                  WASTE WATER TREATMENT &




                                                                                                                                                                          750
        COUPLINGS                                       2
                                                                                                                                                                                                                                                                               22% S                                                              EFFLUENT DISPOSAL SYSTEM




                                                                                                                                                                                             300
    OFFSET ADAPTOR                                      4
                                                                                                                                                                                                                                                                                       LOPE




                                                                                                                                                                                                                                                                150
  OXYGEN DEMAND VENT                                     1

  INSPECTION POINT BASE                                 2                                                                                                                                    900                                    1040                                                                                                         AUTHORISED FOR ISSUE            DATE
   CLEAN COURSE SAND                                   13 m³
                                                                                                                                                                                                               1940                                                                                                                                                             06/11/2024
                                 PUMP DUTY

  HEAD LOSS: PUMPWELL                                  2m                                                                                        RIP & SCARIFY 300mm                                                                                                                                                                             STREET ADDRESS
                                                                                                                                                 APPLY GYPSUM 1kg/m²                                                                                                                                                                             328 UPPER PINBARREN CREEK RD, PINBARREN
  HEAD LOSS: ELEVATION                                 4m
                                                                                                                                                                                                                                                                                                                                                 LOT & PLAN
FRICTION LOSS: RISING MAIN                             4m
                                                                                                                                                                                AES BED SECTION VIEW                                                                                                                                             LOT 3 RP851976
       TOTAL LOSS                                      10 m
                                                                                                                                                                                                                                                                                                                                                 COUNCIL
       RISING MAIN                            ∅32OD ∅26ID PN12.5
                                                                                                                                                                                                                                                                                                                                                 NOOSA SHIRE
                                                                                                                                       ∅100 LOW VENT WITH                                                                             90° ELBOW
     FLOW VELOCITY                                   1.26 m/s                                                                         MOSQUITO PROOF MESH                                                                                                                                                                                        NAME OF CLIENT
                                                                                            TURF ALL FINAL GRADES. NO DEEP ROOTED
       FLOW RATE                             40 L/MIN = 0.67 L/SEC                           PLANTS ON SYSTEM OR OVERFILL AREAS                                                                                                      100mm PVC PIPE                                                                                              VIKI DIOSZOGI
                                                                                                                                                                                                                                                                                                             TYPICAL WARNING SIGN
                                                                                                                                                        150




       PUMP DUTY                             10m HEAD @ 40 L/MIN                                                                                                                                                                                                                                              - COMPLYING WITH AS 1341.9 AT      DESIGNER
                                                                                                                                                                                                                                                                                                                BOUNDARIES OF LAA
                                                                                                                           100
                                                                                                                                                                                                                           OFFSET
                                                                                                                                                                                                                          ADAPTOR
                                                                                                                                                                                                                                        END VIEW                                                              - CLEAR VISIBLE TO PROPERTY        C. TAYLOR
                                                                                                                                                                                                                                                                                                                USERS
                                                                                             GEOTEXTILE                                                                                                                                    GEOTEXTILE            ELBOW LEVEL
                                                                                                                                                                                                                                                                                                              - WORDING SUCH AS "RECYCLED        DRAWN
                                                                                             FIBER WRAP                                                                                                                                    FIBER WRAP            WITH TOP OF
                                                                                         RANDOMLY                                 LEVEL                                                                                                                          OFFSET                                         WATER - AVOID CONTACT -          M. MAHONY
                                                                                                                                                                                                                                              100mm              ADAPTOR                                        DO NOT DRINK"
                                                                                        ORIENTATED
                                                                                                                                                SLOPE                                                                                                   LEVEL
                                                                                         FIBER MAT                                                                                                               RANDOMLY
                                                                                                                                                                                                                ORIENTATED
                                                                                                                                                                                                                                                                                                                                                 DRAWING DETAILS
                                                                                          AES PIPE                                                                                         TOP VIEW              FIBER MAT
                                                                                                                                              OFFSET ADAPTOR                                                                                                                                                     75mm x 50mm HARDWOOD            DETAIL
                                                                                                                                                                                      DO NOT INSERT PVC            AES PIPE                                                                                      POST OR 100mm TREATED
                                                                                                                                                                                      PIPE MORE THAN 100mm
                                                                                                                APPROVED SAND
                                                                                                                                                   ORIGINAL SOIL                      INTO OFFSET ADAPTOR                              SIDE VIEW        OFFSET
                                                                                                                                                                                                                                                                                                                 LOG                             JOB NUMBER
                                                                                                                                                                                                                                                        ADAPTOR
                                                                                                                                                                                                                                                                                                                                                 TE249167
                                                                                                                  LOW VENT                                                                         RAISED CONNECTION                                                                             TYPICAL WARNING SIGN                                SCALE         REVISION         DWG #
                                                                                                                                                                                                                                                                                                                                                      N/a             A              SL3

Page 14

Appendix B AES Design Calculator




Site and Soil Evaluation                   328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                        Page 14 of 19

Page 15

Appendix C Treatment Plant Approval




Site and Soil Evaluation                   328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd                                        Page 16 of 19

Page 16

                       TREATMENT PLANT APPROVAL 06/2024
                    Plumbing and Drainage Regulation 2019, part 4.


Approval

1.    The Advanced Enviro-Septic 30 (AES-30) (“the system”) described in the Specifications and
      Drawings in the attached Schedule and manufactured by Presby Environmental Inc. Whitefield,
      New Hampshire (“the manufacturer”) and supplied by Chankar Environmental Pty Ltd (ACN
      148 175 455) (“the supplier”) has been assessed in accordance with:

         (a) sections 34 and 35 of the Plumbing and Drainage Regulation 2019 and
         (b) the Queensland Plumbing and Wastewater Code published on 26 October 2017.

2.    A transitional Treatment plant Approval (TPA) is granted for an advanced secondary quality
      wastewater treatment system , subject to compliance by the manufacturer/supplier with the
      requirements of the Plumbing and Drainage Act 2018 and the conditions of approval detailed
      below.

3.    As no changes have been made to the system, this approval replaces the previous approval,
      TPA 15/2019 Amendment 2 issued on 20 January 2023.

4.    This approval, the conditions of approval, and the Schedule comprise the entire TPA document.

5.    Any modification by the manufacturer/supplier to the design, drawings or specifications
      scheduled to this approval must be approved by the Chief Executive.

 Conditions of approval

6.    The manufacture, installation, operation, service, and maintenance of the system must be in
      conformity with the conditions of this TPA.

7.    The advanced secondary quality wastewater treatment system, which is an example of the
      approved systems, may only be used on premises that generate per day:

         a) a maximum hydraulic loading of 90 L per 3 m length of AES piping system.
         b) a maximum organic loading of 240 mg/L BOD5.
         c) a maximum total suspended solids of 300 mg/L.

8.    The system must continue to meet the requirements of an advanced secondary quality
      wastewater treatment system, producing the following effluent quality —

         a) 90% of the samples taken must have a BOD5 less than or equal to 10 g/m³ with no sample
            greater than 20 g/m³.
         b) 90% of the samples taken must have total suspended solids less than or equal to 10 g/m³
            with no sample greater than 20 g/m³.
9.    Each system must be serviced in accordance with the details supplied in the owner’s operation
      and maintenance manual.

10.   The system design is based upon secondary quality effluent design loading rate as defined in
      AS/NZ1547 using the Advanced Enviro-Septic (AES) Design Calculator prepared by a qualified
      designer. System designs must be verified and signed by the supplier before being submitted to
      the Local Government.




                                                 1

Page 17

                          TREATMENT PLANT APPROVAL 06/2024
                       Plumbing and Drainage Regulation 2019, part 4.

11.   A septic tank conforming to AS/NZ 1546.1 and sized in accordance with AS/NZ 1547 for
      treatment of all daily flows of domestic wastewater from the premises is a component of the
      system. Effluent from the septic tank is to be diverted to the AES piping system prior to the system
      sand and basal area. The septic tank that feeds into the system must be regularly monitored and
      maintained (including de-sludging) in accordance with AS/NZ 1547 to ensure optimum operation
      of the system.

12.   Where gravity cannot be achieved to transfer effluent from septic tank to the AES treatment pipes:

            (a) A pump well is to be used and sized as per AS/NZ1547:2012 and maintain at least 24-
                hour emergency storage above the high-water level alarm sensor.

            (b) The pump is to be a submersible type with high level alarm as specified in both
                AS1546.3:2017 and AS/NZ 1547:2012. The pump shall be a Davey D25VA or equivalent,
                with a design flow of 40 L/min at a minimum 6 m head. Should site conditions require a
                higher head, then the appropriate pump model to achieve this shall be selected.

            (c) In each situation, the design of the AES system must confirm with the manufacturer’s
                design recommendations set out in the AES Calculator & Design and Installation Manual.

13.   When granting a compliance permit, the local government must satisfy itself that the designer’s
      choice of the system configuration is optimal for the proposed use and site conditions and that
      the effluent can be retained within the land application area.

14.   Each application for a compliance permit to install a system must also be accompanied by a copy
      of a completed AES Design Calculator Report endorsed by the supplier, showing the
      footprint/basal area of the proposed system and number of pipe modules for the site.

15.   An inspection/sampling point must be installed permanently in the sand immediately below the
      half-way point of the AES piping system. Where a system is installed in a sloping basal area an
      additional inspection/sampling point must be installed at the lowest point of the system extension.

16.   Routine maintenance of the system at set intervals, other than septic tank sludge levels, is not
      stipulated by the manufacturer/supplier. However, routine monitoring may be required by the
      Local Government. In the event of failure of the system’s land application area an AES
      authorised person may need to follow the rejuvenation procedures set out in the
      manufacturer/supplier’s Design and Installation Manual.

17.   Where a system installed at a site, has been found not to operate satisfactorily during its service
      life, and as a result requires modification to achieve the required performance requirements, in
      particular, water quality limits, the installed system is to be modified accordingly. Any
      modifications including any of the supplier’s rejuvenation procedure outcomes must be recorded
      on the service report.

18.   Permitted use of the effluent is for sub-surface absorption only.

19.   Each system must be supplied with —

      (a)     a copy of this Treatment Plant Approval document;
      (b)     details of the system;
      (c)     instructions for authorised persons for its installation;
      (d)     a copy of the owner’s manual to be given to the owner at the time of installation; and
      (e)     detailed instructions for authorised service personal for its operation and maintenance.



                                                      2

Page 18

                        TREATMENT PLANT APPROVAL 06/2024
                     Plumbing and Drainage Regulation 2019, part 4.

20.   At each anniversary of the TPA date, the supplier must submit to the Chief Executive a list of all
      systems installed in Queensland during the previous 12 months. Where the Chief Executive is
      notified of any system failures the Chief Executive may randomly select several installed systems
      for audit. The Chief Executive will notify the supplier’s nominated NATA accredited laboratory
      which systems are to be audited for BOD5 and TSS. The sampling and testing of the selected
      systems, if required, is to be done at the supplier’s expense. The following results must be
      reported to the Chief Executive:

      a) Address of premises;
      b) Date inspected and sampled;
      c) Sample identification number;
      d) BOD5 for influent and effluent; and
      e) TSS for influent and effluent.
 21. The Chief Executive may, by written notice, cancel this approval if the manufacturer/supplier fails
     —
      a) to comply with one or more of the conditions of approval; or
      b) within 30 days, to remedy a breach, for which a written notice been given by the Chief
         Executive.
22.   This approval may only be assigned with the prior written consent of the Chief Executive.

23.   Where there is any inconsistency between the content of this approval and the Plumbing and
      Drainage Act 2018 (including any associated regulation and/or codes), the provisions of the
      Plumbing and Drainage Act 2018 will apply and must be adhered to.

24.   This approval expires on 1 January 2025 unless cancelled earlier in accordance with paragraph
      21 above.



Lindsay Walker




Director                                                                                               Level 15,
Plumbing, Drainage and Special Projects                                               53 Albert Street Brisbane

Date approved: 26 April 2024.                                                 GPO Box 2457, Brisbane Qld 4001
                                                                                  Telephone +61 7 3008 2557
                                                                              Website www.business.qld.gov.au




                                                   3

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.