Site and Soil Evaluation
On-Site Wastewater and Effluent Disposal System Design
Tiny Home
328 Upper Pinbarren Creek Road,
Pinbarren Qld 4568
Report # TE249167
Issue A
Date 6 Nov. 24
OFFICES IN BRISBANE, TOOWOOMBA, GOLD COAST, HERVEY BAY. SERVICING WIDER QUEENSLAND
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 17 pages
Page 2
1 Introduction
1.1 Background
Taylor Environmental (Australia) Pty Ltd was engaged to design a new on-site wastewater treatment
and effluent disposal system for the tiny home installed at 328 Upper Pinbarren Creek Road, Pinbarren
Qld 4568.
This property is not serviced by a municipal sewer network and requires all wastewater to be managed
on site. The purpose of this report is to design a domestic wastewater management system that meets
the requirements of AS1547 and the Queensland Plumbing and Wastewater Code.
1.2 Proposal
The tiny home, on a trailer next to the dams, has a composting toilet with leachate drain, with greywater
being disposed to land.
It is proposed to install a compliant wastewater management system consisting of:
• A partitioned septic tank for the greywater and small volume of composting liquid, with an
advanced enviro septic bed (AES)
1.3 Scope of Works
The scope of works for this Site and Soil Evaluation are outlined below:
• Undertake a desktop study of the property, including a review of the development, sensitive
environments, geology and slope
• Carry out a site inspection (31 October 2024)
• Investigate the receiving soil
• Determine a suitable location and method of effluent disposal
• Prepare plans for the wastewater management system for Council consideration
1.4 Legislation and Standards
This report has been completed in accordance with the relevant legislative requirements:
• Plumbing and Drainage Act
• Plumbing and Drainage Regulation
• Queensland Plumbing and Wastewater Code
• AS/NZS 1547:2012 On-site Domestic Wastewater Management
• AS1546.3:2017 Secondary Treatment Systems
• Plumbing Code of Australia (PCA)
1.5 Approvals
Before commencing the work, this Site and Soil Evaluation (Deemed to Satisfy) must be submitted and
approved by the local Council as Permit Work under the Plumbing and Drainage Regulation 2019.
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 2 of 19
Page 3
2 Site and Soil Assessment
2.1 Property Details
Details of the subject property are presented in Table 1, below.
Table 1: Property Details
Feature Details
Property Address 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Lot and Plan Lot 3 RP851976
Local Authority Noosa Shire Council
Property size 25.63 ha
Water Supply Reticulated water
Zone Rural
Water Catchments Not located in a water catchment or buffer area
Figure 1 shows the subject property.
Tiny Home
Figure 1: Subject Property
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 3 of 19
Page 4
2.2 Site Assessment Table 2 outlines the site assessment for this development. Table 2: Site Details Feature Details Elevation ≈130-135m AHD Slope Levelled building area with upto 22% slope behind Slope configuration Linear planar Exposure Good exposure Aspect North to north west Permanent surface waters Several dams in the middle of the development area Intermittent surface waters Drains/gullies linking dams Flood hazard n/a - no flood overlays present on the property Groundwater bores Groundwater bore near paddocks to the west Vegetation Mostly grassed, with few small trees remaining Environmental Areas n/a – wastewater system in grassed area Figure 1 shows the tiny home. The wastewater system will be on the grassed hill behind. Figure 2: Tiny Home Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568 Taylor Environmental (Australia) Pty Ltd Page 4 of 19
Page 5
2.3 Soil Investigation
The site and soil evaluation was undertaken on 31 October 2024, with earlier soil tests undertaken by
Global Testing in 2019. The soil profile and design characteristics for the effluent disposal area are
presented in Table 3.
Table 3: Soil Type
BH1 BH2
Sandy Clay, Category 4 Sandy Clay, Category 4
0 – 500 0 – 500
Low plasticity Low plasticity
Sandy Clay, Red/brown Sandy Clay, Red/brown
500 – 1200 500 – 1200
Medium plasticity Medium plasticity
Ksat 0.20 m/day Ksat 0.22 m/day
Design Characteristics
Receiving depth Basal area will be around 900mm deep
Texture Light Clay
Structure Strongly Structured
Category 5
Design Loading Rate (DLR) 12 mm/day for secondary+ effluent
2.4 Habitable Buildings
This property has a number of habitable buildings with wastewater systems. Table 4 below online each
building and its number of Equivalent Persons in reference to the Environmental Protection Regulations
Equivalent Persons.
Table 4: Habitable Buildings
ERA63 Equivalent
Building Bedrooms AS1547 Persons1
Persons2
Tiny house 1 br 2 persons = 300L 1.5 EP
Vistor Accomodation #1 1 br 2 persons = 300L 1.5 EP
Visitor Accommodation #2 2 br 3 persons = 450L 2.25 EP
Visitor Accommodation #3
1 br 2 persons = 300L 1.5 EP
“Mango Tree Cabin”
Caretakers 3 br 5 persons = 750L 3.75 EP
Granny Flat 2 br 3 persons = 450L 2.25 EP
Primary Residence 3 br 5 persons = 750L 3.75 EP
Total 13 br 22 persons = 3300L 16.5 EP
1
Where 1 person = 150 L/day
2
Where 1 Equivalent Person = 200 L/day
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 5 of 19
Page 6
3 Proposed Wastewater System
3.1 Proposed Wastewater System
It is proposed to relace the composing tank leachate drain and the greywater disposal with a partitioned
septic tank and advanced enviro septic (AES) bed. A 10m setback is required to the surface waters, and
as such a pump is required in the second chamber of the septic tank.
3.2 Design Details
Table 4 below presents the features of the proposed wastewater system.
Table 5: Design Features
Feature Details
Water supply Rain water / bore water
Volume Allowance 1503 L/person/day
Design Volume Number of bedrooms 1
Design population 2
Total Design Volume (Q) 300 L/day
Category 5
Soil Characteristics
Design Loading Rate (DLR) 12 mm/day
Septic tank capacity 3000 L (min) partitioned tank, with pump
Treatment facility Advanced Enviro Septic (AES)
Treatment System
Treatment plant approval 06 - 2024
Treatment level Advanced secondary
Required disposal area A = Q/DLR = 25 m2
Disposal Area Footprint as per
12.9m x 1.94m = 25 m2
AES Design Calculator
The design of the AES system is presented in Appendix A.
The Advanced Enviro-Septic Approved Design Calculator is presented in Appendix B.
The AES Treatment Plant Approval is presented in Appendix C.
General requirements and notes
• 100% reserve area to be kept clear of permanent structures
• Deep rip base of beds and spread gypsum at 1kg/m2
• Grass is to be established in the land application area, and mown regularly
• Stormwater should not traverse the land application area. Construct a stormwater diversion
upslope
• General access to the land application area by pedestrians, vehicles and animals is to be
generally excluded
• Install at least 2x ‘effluent reuse’ warning signs around land application area
• The system is to be installed, operated and serviced in accordance with manufacture
specifications
• The land application area has been designed based on a daily wastewater volume in accordance
with AS1547. Any exceedance of this design volume may have adverse effects on the land
application area
3
Conservative volume allowance, as composting toilets have very low discharge volumes
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 6 of 19
Page 7
3.3 Effluent Quality
Table 5 below presents the effluent standards produced by approved wastewater treatment systems
with subsurface disposal, as per AS1546.3:2017 Secondary Treatment Systems.
Table 6: Effluent Quality
Secondary Effluent Advanced Secondary Effluent
Parameter
90% of samples Maximum 90% of samples Maximum
BOD5 < 20 mg/L 30 mg/L < 10 mg/L 20 mg/L
TSS < 30 mg/L 45 mg/L < 10 mg/L 20 mg/L
The proposed treatment plant has approvals for Advanced Secondary effluent.
3.4 Setback Distances
The Queensland Plumbing and Wastewater Code V1:2024 Appendix 1 outlines minimum setback
separation distances required for onsite wastewater management facilities. This design complies with
the relevant setbacks.
The ‘Land Application Area Setback Distances’ (QPWC Table T2) are presented in Table 6.
Table 7: Separation Distances: Subsurface land application areas
Separation Distance
Feature
Upslope Downslope Level
Property boundaries, pedestrian paths, walkways,
recreation areas, retaining wall, and footings for buildings 2m 4m 2m
and other structures
Inground swimming pools 6m 6m 6m
Inground potable water tank not exposed to primary
6m 6m 6m
effluent
Inground potable water tank exposed to primary effluent 15 m 15 m 15 m
*Distances are given in meters and are measured from the edge of trench/bed excavation or subsurface irrigation distribution
pipework to the nearest point of the feature
The ‘Protection of Surface Water and Groundwater Setback Distances’ (QPWC Table T5) are presented
in Table 7.
Table 8: Separation Distances: Protection of Surface Water and Groundwater
Feature Separation Distance
Effluent Quality Adv. Sec. Secondary Primary
Top of bank of permanent water course 10 m 30 m 50m
Top of bank of intermittent water course 10 m 30 m 50m
Top of bank of a lake, bay or estuary 10 m 30 m 50m
Top water level of a surface water source used for
10 m 30 m 50m
agriculture, aquaculture or stock purposes
Open stormwater drainage channel or drain 10 m 30 m 50m
Bore or dam 10 m 30 m 50m
Unsaturated depth to a permanent water table (vertical) 0.3 m 0.6 m 1.2m
*Distances are given in meters and are measured from,
- any part of the on-site sewage facility (including pipes and fittings) and,
- the edge of irrigated wetted area of the Land Application Area to the feature as listed.
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 7 of 19
Page 8
4 Maintenance
Property owners have a responsibility to ensure the onsite wastewater treatment and effluent disposal
system is maintained and serviced. The following servicing and precautions are to be undertaken:
• Septic tanks to be checked annually and pumped out when 1/3 full of solids or once every 5
years, whichever is sooner
• Read and follow the Owner's Manual that is provided with the system
• Comply with local authority’s servicing requirements
• Do not manipulate the system so that it no longer complies with the Council issued permit or
the plans located in Appendix A of this document
• Maintain the land application area e.g. regularly mowed and ensure that there is no ponding
of effluent
• Vehicles, animals and general access to the land application area is to be generally restricted
with warning signs erected
• Use low sodium biodegradable soaps and detergents as per the label instructions and no paints,
solvents, chemicals, food scraps, fats, oils or any other solids to be disposed of “down the drain”
• It is always good practice to minimise / stagger high wastewater generating activities such as
laundry over a full week
• On-site sewage systems are not designed to cope with the flow from garbage grinders
The design was completed by Chris Taylor (Director, Taylor Environmental (Australia) Pty Ltd, QBCC
Licence Number 150 556 72).
Chris Taylor MEnvMan, BAppSc(Chem), ADCivEng Cert IV DWM003
Director | Taylor Environmental (Australia) Pty Ltd
6 Nov. 24
Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568
Taylor Environmental (Australia) Pty Ltd Page 8 of 19
Page 9
Appendix A Design Drawings Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568 Taylor Environmental (Australia) Pty Ltd Page 9 of 19
Page 10
PROJECT:
REVISIONS
ONSITE WASTEWATER TREATMENT AND EFFLUENT DISPOSAL SYSTEM #
A
DATE SUBJECT
06/11/2024 REVISION A
AUTHORISED
C. TAYLOR
FOR TINY HOME AT 328 UPPER PINBARREN CREEK ROAD, PINBARREN
GENERAL NOTES LEGEND
1. LOCATION OF HSTP, ORG, VENT PIPE AND OTHER WASTE PIPES TO BE DETERMINED BY PROPERTY BOUNDARY TAYLOR ENVIRONMENTAL
PLUMBER EASEMENT
2. REFER TO COMPLIANCE PERMIT FOR CONDITIONS OF COUNCIL APPROVAL CONTOUR - MINOR
3. PROPERTY FEATURES, STRUCTURES AND CONTOURS HAVE BEEN REPRODUCED BASED ON CONTOUR - MAJOR
THE BEST AVAILABLE INFORMATION AND MAY NOT BE COMPLETE OR ACCURATE DECOMMISSION
4. THE SYSTEM INSTALLER IS RESPONSIBLE TO ESTABLISH THE LOCATION, LEVELS AND
DEPTHS OF ALL EXISTING SERVICES ON-SITE PRIOR TO COMMENCING ANY WORKS MSES VEGETATION
5. LOCATIONS AND SETOUT DIMENSIONS SHOWN ARE APPROXIMATE ONLY AND ARE TO BE VEGETATION LINE
CONFIRMED ON SITE. TREE LINE
6. ACCESS AND LAY DOWN AREAS ARE TO BE CONFIRMED BY THE SYSTEM INSTALLER PROTECTED TREE
7. EXISTING BUILDINGS AND EXTERNAL STRUCTURES SHOWN ON THESE DRAWINGS ARE INTERMITTENT WATERBODY
OBTAINED FROM THE AVAILABLE INFORMATION AND MAY NOT BE COMPLETE AND PERMANENT WATERBODY
ACCURATE FLOW PATH
8. ALL DIMENSIONS ARE IN MM U.N.O DEFINED FLOOD LINE
9. PLUMBING AND DRAINAGE TO QLD PLUMBING & WASTEWATER ACT, AS / NZS 3500 CHANGE OF GRADE
10. ALL PIPE WORK TO AS / NZS 4020 TOP OF BANK
11. ALL TANKS TO BE INSTALLED AND ANCHORED IN COMPLIANCE WITH THE RETAINING WALL
MANUFACTURERS SPECIFICATIONS
12. FLEXIBLE JOINTS ON ALL INSTALLED TANKS (AS / NZS 3500) WASTEWATER COMPONENT
13. THERE SHALL BE NO CROSS CONNECTION BETWEEN ANY WASTEWATER / EFFLUENT GRAVITY DRAINAGE - NEW
PIPEWORK AND ANY POTABLE WATER SUPPLY PIPEWORK GRAVITY DRAINAGE - EXISTING
14. MINIMUM DISTANCE BETWEEN TANKS AND BUILDINGS TO BE MAINTAINED (AS/NZS 3500) RISING MAIN - NEW
15. USE ONLY A LICENSED DRAINER THAT HAS BEEN ACCREDITED BY THE SYSTEM RISING MAIN - EXISTING
SUPPLIER.
16. FINAL LOCATION OF THE LAND APPLICATION AREA AND ASSOCIATED PIPE WORK CAN STORMWATER PIPE
ONLY BE ALTERED ON SITE TO MEET THE SITE CONDITIONS AFTER APPROVAL FROM WATER MAINS
TAYLOR ENVIRONMENTAL (AUSTRALIA) PTY LTD ELECTRICAL - OVER HEAD
QBCC LICENCE NUMBER 150 556 72
17. GRADE ALL BATTERS EVENLY AT 1 IN 5, UNLESS NOTED OTHERWISE ELECTRICAL - UNDERGROUND ABN NUMBER 95268308955
18. ANY SOILS ENCOUNTERED WHICH SHOW EVIDENCE OF CONTAMINATION ARE TO BE COMMS SERVICES
STOCKPILED SEPARATELY. CONTAMINATED SOIL SHALL BE HANDLED IN ACCORDANCE NBN SERVICES
WITH ALL WORKPLACE HEALTH & SAFETY AND ENVIRONMENTAL REGULATIONS TELSTRA SERVICES
Phone: +61 400 301 364
19. IT IS THE INSTALLERS RESPONSIBILITY TO PROVIDE ACCURATE 'AS CONSTRUCTED' GAS SERVICES Email: [email protected]
DRAWINGS TO RELEVANT LOCAL AUTHORITY AND INCUR ASSOCIATED COST FIRE MAIN SERVICES Web: www.taylorenviro.com.au
20. ALL DISTURBED AREAS TO BE REINSTATED TO NATURAL GROUND CONDITIONS
21. EXISTING TOPSOIL IS TO BE RETAINED AND SET ASIDE (WINDROWED) TO PREVENT
DAMAGE FROM MACHINERY AND REDISTRIBUTED ONCE INSTALLATION IS COMPLETE
22. AT LEAST A 5 TONNE MACHINE WITH POSI-TRACK SYSTEM IS REQUIRED FOR ABBREVIATIONS
EARTHWORKS TO ELIMINATE POTENTIAL TRACK INDENTATIONS INTO GROUND LEVEL
23. ALL MATERIALS SHALL BE NEW, PROVEN IN SERVICE AND SUITABLE FOR THE INTENDED AAV AIR ADMITTANCE VALVE
USE AES ADVANCED ENVIRO SEPTIC OSSF SYSTEM
24. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENGAGE THE DESIGNER TO AS
B
AUSTRALIAN STANDARD
HAND BASIN PIN WASTE WATER TREATMENT &
UNDERTAKE INSPECTIONS DURING INSTALLATION. FAILURE TO DO SO WILL RESULT IN BARR
THE FORM 8 / COMMISSIONING CERTIFICATE NOT BEING ABLE TO BE COMPLETED BTH
COS
BATH TUB
CLEAR OUT TO SURFACE EN EFFLUENT DISPOSAL SYSTEM
25. DO NOT SCALE FROM DRAWINGS CRE
26. TAYLOR ENVIRONMENTAL TAKES NO RESPONSIBILITY FOR WORKS UNDERTAKEN BY THE CS CLEANERS SINK EK
INSTALLER AND/OR INSTALLATIONS THAT ARE NOT IN ACCORDANCE WITH THESE PLANS DG DISCONNECTOR GULLY
27. THESE PLANS ARE TO BE READ IN CONJUNCTION WITH THE SITE AND SOIL REPORT, DW DISHWASHER AUTHORISED FOR ISSUE DATE
ARTICULATED JOINT DESIGN AND REGULATOR ISSUED COMPLIANCE PERMITS e?? EXISTING ITEM
FFL FINISHED FLOOR LEVEL
FSL FINISHED SURFACE LEVEL UP
SANITARY DRAINAGE AND PLUMBING PE 06/11/2024
1. SANITARY DRAINAGE SHALL BE ∅100 UPVC AT A 1:60 MINIMUM GRADE FWG FLOOR WASTE GRATE R PIN
2. IO's UNDER CONCRETE/IMPERMEABLE GROUND COVERINGS SHALL BE TAKE TO SURFACE HSTP HOME SEWAGE TREATMENT PLANT BA
LEVEL AS AN IOS AND FITTED WITH AN APPROVED SCREW CAP IL INVERT LEVEL RR STREET ADDRESS
3. ORG' RISERS SHALL BE TO AS3500.2 AND EXTEND TO AN APPROVED GRATE AT 150mm IO INSPECTION OPENING EN
IOS INSPECTION OPENING TO SURFACE C RE 328 UPPER PINBARREN CREEK RD, PINBARREN
BELOW LOWEST FIXTURE, 75mm ABOVE GROUND LEVEL AND ABOVE DEFINED FLOOD EK
IV INDEXING VALVE
LEVEL
LAA LAND APPLICATION AREA
RO LOT & PLAN
4. UNDERSLAB SANITARY DRAINAGE SHALL BE INSTALLED IN ACCORDANCE WITH THE AD
LT LAUNDRY TUB
ARTICULATED JOINT DESIGN (WHERE REQUIRED) AND AS3500.2 APPENDIX G
NGL NATURAL GROUND LEVEL LOT 3 RP851976
5. LAGGING IN ACCORDANCE WITH AS3500
ORG OVERFLOW RELIEF GULLY
6. BURIED PIPEWORK SHALL BE 200mm DEEP IN NON TRAFFICABLE AREAS AND 500mm
OSSF ON-SITE SEWAGE FACILITY
COUNCIL
DEEP IN TRAFFICABLE AREA, OR IN ACCORDANCE WITH AS3500
RL REDUCED LEVEL NOOSA SHIRE
INSTALLATION S SINK
1. IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE THAT ALL COMPONENTS COMPLY SHR SHOWER NAME OF CLIENT
WITH THESE GUIDES UPON COMMISSIONING OF THIS SYSTEM ST STACK
2. ALL BURIED PIPE WORK IS TO BE IDENTIFIED WITH UNDERGROUND MARKING TAPE UR URINAL VIKI DIOSZOGI
PLACED ABOVE THE PIPE WORK V VENT
WC WATER CLOSET DESIGNER
3. ALONG THE BOUNDARY OF THE LAND APPLICATION AREA THERE SHALL BE AT LEAST 2
WARNING SIGNS CLEARLY VISIBLE TO ADVISE THAT RECYCLED WATER IS USED (EACH C. TAYLOR
SIGN SHALL COMPLY WITH AS1319 AND HAVE THE WORDING RECYCLED WATER - AVOID
CONTACT DO NOT DRINK) DRAWN
MAINTENANCE M. MAHONY
1. SYSTEM TO BE SERVICED AND MAINTAINED IN ACCORDANCE WITH MANUFACTURE
DRAWING DETAILS
SPECIFICATIONS AND COUNCIL GUIDELINES
2. SEPTIC TANKS TO BE CHECKED FOR SOLIDS BUILD UP ANNUALLY SUBJECT PROPERTY TITLE PAGE
3. SEPTIC TANKS TO PUMPED OUT IF 31 FULL OF SOLIDS OR 5 YEARS (WHICHEVER IS
SOONER) 1:7500 @ A3 JOB NUMBER
4. LAND APPLICATION IS IMPORTANT AND IS TO BE REGULARLY MOWED AND ANIMALS
AND VEHICLES EXCLUDED TE249167
SCALE REVISION DWG #
1:7500 A SL0
Page 11
FOR VISUALISATION ONLY.
REFER TO DETAILED PLAN FOR
SYSTEM DETAILS REVISIONS
# DATE SUBJECT AUTHORISED
AT
FL
A 06/11/2024 REVISION A C. TAYLOR
NY
AN
GR
&
BIN
CA
TO
TO PR
TAYLOR ENVIRONMENTAL
IMARY
APPROVED UNDER MCU19/0053
FA
SH RM
R
ESIDEN
APPROVED UNDER ED
MCU20/0084 3br SHED
CARE
CE
TAKERS
R UNIT
ITO
VIS M. #2 ORIGINAL SEPTIC
O
ACC (2br) AND GREYWATER
R
ITO 1 SYSTEMS
VIS M. #
O
ACC (1br)
DAM
QBCC LICENCE NUMBER 150 556 72
ABN NUMBER 95268308955
Phone: +61 400 301 364
SEPTIC TANK AND AES Email: [email protected]
BED APPROVED UNDER Web: www.taylorenviro.com.au
AES BE
D MCU20/0084
DAM WASTE WATER TREATMENT &
EFFLUENT DISPOSAL SYSTEM
265
10m SURFACE
00
WATER SETBACK
AUTHORISED FOR ISSUE DATE
24000
06/11/2024
BORE
HOM NY
STREET ADDRESS
E
TI
STABLES
328 UPPER PINBARREN CREEK RD, PINBARREN
1br
LOT & PLAN
LOT 3 RP851976
COUNCIL
PROPOSED SEPTIC TANK (WITH NOOSA SHIRE
PUMP) AND AES WASTEWATER NAME OF CLIENT
BED FOR GREYWATER &
VIKI DIOSZOGI
STABLES
COMPOSTING TOILET LEACHATE
DESIGNER
C. TAYLOR
DRAWN
S M. MAHONY
BLE
STA DRAWING DETAILS
SITE LAYOUT
JOB NUMBER
TE249167
SITE LAYOUT SCALE REVISION DWG #
1:750 @ A3 1:750 A SL1
Page 12
NOTE: THE AES SYSTEM TREATMENT PLANT GENERAL NOTES:
APPROVAL (TPA) 06-2024 LAPSES ON 1 - LOCATION OF HSTP, ORG, VENT PIPE AND OTHER
JANUARY 2024. THIS DESIGN MUST BE WASTE PIPES TO BE DETERMINED BY PLUMBER
INSTALLED PRIOR TO THIS DATE, OTHERWISE - REFER TO COMPLIANCE PERMIT FOR CONDITIONS OF
A COUNCIL AMENDMENT MAY BE REQUIRED COUNCIL APPROVAL REVISIONS
SEPTIC TANK / PUMPWELL: # DATE SUBJECT AUTHORISED
- TO BE INSTALLED AS PER MANUFACTURERS A 06/11/2024 REVISION A C. TAYLOR
SPECIFICATION
- SWIVEL KNUCKLE AND EXPANSION JOINTS TO BE
INSTALLED ON INLET PIPE
- SUBMERSIBLE TRANSFER PUMP WITH PUMP
FAILURE ALARM
- VENTING AS PER AS3500.2 SECTION 12.6.3
AES SYSTEM:
- TO BE INSTALLED AS PER MANUFACTURERS
SPECIFICATIONS AND BY A SUPPLIER APPROVED
PERSON
- DEEP RIP BASE OF BED AND SPREAD GYPSUM AT
1kg/m2 TAYLOR ENVIRONMENTAL
PROPOSED PARTITIONED SEPTIC TANK FOR GREYWATER - 150mm MIN TOPSOIL OVER AES SAND BED
- GRASS/TURF OVER BED
· 3000L (MINIMUM) CAPACITY - NO TREES WITHIN 2m OF BED
· EG: EVERHARD POLY 3000L #87003 SIMILAR - 3m HIGH VENT AND VELOCITY REDUCER REQUIRED
· EXACT LOCATION TO BE CONFIRMED BY INSTALLER FOR PUMPED DELIVERY
· INSTALL SUBMERSIBLE TRANSFER PUMP IN SECOND
CHAMBER:
APPROX LOCATION OF LEACHATE ·· DAVEY D25VA (OR EQUIVALENT) WITH DUTY
DRAIN TO BE ABANDONED OF 40 L/MIN @ 10m HEAD
·· PUMP FAILURE ALARM
·· VENTING AS PER AS3500.2 SECTION 12.6.3
COMPOSTING TOILET TANK
(CLIVUS MULTRUM). RE-DIRECT
LEACHATE TO NEW SEPTIC TANK
1940
15000 22%
SLO
DAM PE
QBCC LICENCE NUMBER 150 556 72
E
RESERVE AREA
HOM
ABN NUMBER 95268308955
TINY
Phone: +61 400 301 364
Email: [email protected]
1br
Web: www.taylorenviro.com.au
12900
WASTE WATER TREATMENT &
EFFLUENT DISPOSAL SYSTEM
200
APPROX CUT BANK INSTALL 1m LONG VELOCITY AUTHORISED FOR ISSUE DATE
0
REDUCER AND 3m TALL 'HIGH
VENT' AT DELIVERY POINT 06/11/2024
STREET ADDRESS
328 UPPER PINBARREN CREEK RD, PINBARREN
LAND APPLICATION AREA LOT & PLAN
· AES BED [TPA 06-2024] LOT 3 RP851976
· 12.9m LONG x 1.94m WIDE = 22m² COUNCIL
· 1 ROW OF 4 AES PIPES
· CURVE AROUND SLOPE AS REQUIRED NOOSA SHIRE
· ESTABLISH GRASS OVER FINISHED BED. TO BE MOWN NAME OF CLIENT
REGULARLY BY HOMEOWNER VIKI DIOSZOGI
· NO TREES PERMITTED WITHIN 2m OF BED
· DRIVING OVER LAND APPLICATION AREA TO BE DESIGNER
GENERALLY AVOIDED. DO NOT PARK ON THE BED C. TAYLOR
· STORMWATER TO BE DIVERTED AWAY FROM BED
DRAWN
· THIS LAND APPLICATION AREA IS DESIGNED FOR A
MAXIMUM HYDRAULIC LOADING OF 300L/DAY M. MAHONY
· 100% RESERVE AREA TO BE LEFT CLEAR OF DRAWING DETAILS
PERMANENT STRUCTURES
RISING MAIN PROPOSED WORKS
· ∅32od ∅26id PN12.5 LILAC
JOB NUMBER
COLOURED POLYETHYLENE
· INDICATIVE ALIGNMENT SHOWN TE249167
PROPOSED WORKS · BURY PER AS3500.1 SCALE REVISION DWG #
1:200 @ A3 1:200 A SL2
Page 13
SOIL CHARACTERISTICS
0 - 300 LOW PLASTICITY SANDY CLAY LOAM
SOIL PROFILE AT BH1
300 - 1200 MEDIUM PLASTICITY SANDY CLAY REVISIONS
3m HIGH VENT. ATTACH TO
BOLLARD FOR SUPPORT # DATE SUBJECT AUTHORISED
CLAY LOAM AT 900 DEEP
RECEIVING SOIL A 06/11/2024 REVISION A C. TAYLOR
(AES BASAL AREA)
OFFSET ADAPTER COUPLING STRAIGHT RAISED CONNECTOR ∅100 LOW VENT
STRUCTURE STRONGLY STRUCTURED ∅100 uPVC
VELOCITY REDUCER
SOIL CATEGORY 5 [1m LONG MIN]
900
PERMEABILITY (KSAT) 0.12 - 0.5 m/DAY
DESIGN LOADING RATE 12 mm/DAY ∅32OD ∅26ID PN12.5
1940
DESIGN VOLUME
LILAC COATED PIPE INSPECTION POINT
1040
3m LONG ∅300 AES PIPE
WATER SUPPLY RAIN WATER & BORE WATER 1 ROW OF 4 PIPES INSPECTION POINT
150 L/P/DAY TAYLOR ENVIRONMENTAL
VOLUME ALLOWANCE (CONSERVATIVE ALLOWANCE WITH COMPOSTING
TOILET) 300 6000 300 6000 300
NUMBER OF BEDROOMS LOFT BEDROOM
12900
DESIGN POPULATION 2 PERSONS
TOTAL DESIGN VOLUME 300 L/DAY
TREATMENT AES BED PLAN VIEW AES BED CONSTRUCTION:
- TO BE INSTALLED AS PER MANUFACTURERS
SEPTIC TANK CAPACITY 3000L MIN SPECIFICATIONS AND BY A SUPPLIER APPROVED PERSON
- EXCAVATE WITH LASER LEVEL
ADVANCED ENVIRO SEPTIC (AES) - RIP LEVEL OF BASE ≈200 to 300mm
TYPE OF FACILITY
MODEL: 30L/MIN - RE-EXCAVATE BACK TO CORRECT LEVEL USING A LASER
LEVEL
TREATMENT LEVEL ADVANCED SECONDARY - GYPSUM BASE AT 1kg/m2
06 - 2024 - PLACE AES APPROVED SAND TO SPECIFIED DEPTH
TPA UNDER PIPES
(LAPSES 1 JAN 2025)
MIN 3m
∅100 HIGH VENT - PLACE AES PIPES AND CONNECTORS, ENSURING THEY
DISPOSAL AREA ARE LEVEL ACROSS THE ENTIRE LENGTH
- PLACE AES APPROVED SAND TO SPECIFIED DEPTH
MINIMUM AES AREA REQUIRED A = Q/DLR = 25m² OVER PIPES
INSPECTION POINT - REPLACE EXCAVATED TOP SOIL TO A MINIMUM DEPTH QBCC LICENCE NUMBER 150 556 72
AES FOOTPRINT AS PER BACK FILL MOUND OVER AES OF 150mm ABN NUMBER 95268308955
12.9m x 1.94m = 22 m² - ESTABLISH GRASS TO PROMOTE EVAPOTRANSPIRATION
AES DESIGN CALCULATOR
STORMWATER - NO TREES WITHIN 2m OF BED
NUMBER OF AES PIPE ROWS 1 ROWS DIVERSION APPROVED SAND Phone: +61 400 301 364
∅100 LOW VENT Email: [email protected]
150 MIN
NUMBER OF AES PIPES/ROW 4 PIPES/ROW GRASS Web: www.taylorenviro.com.au
BUFFER CAPACITY 869 L INSPECTION POINT
BILL OF QUANTITIES
150
150 MIN
AES PIPES 4
300 300
WASTE WATER TREATMENT &
750
COUPLINGS 2
22% S EFFLUENT DISPOSAL SYSTEM
300
OFFSET ADAPTOR 4
LOPE
150
OXYGEN DEMAND VENT 1
INSPECTION POINT BASE 2 900 1040 AUTHORISED FOR ISSUE DATE
CLEAN COURSE SAND 13 m³
1940 06/11/2024
PUMP DUTY
HEAD LOSS: PUMPWELL 2m RIP & SCARIFY 300mm STREET ADDRESS
APPLY GYPSUM 1kg/m² 328 UPPER PINBARREN CREEK RD, PINBARREN
HEAD LOSS: ELEVATION 4m
LOT & PLAN
FRICTION LOSS: RISING MAIN 4m
AES BED SECTION VIEW LOT 3 RP851976
TOTAL LOSS 10 m
COUNCIL
RISING MAIN ∅32OD ∅26ID PN12.5
NOOSA SHIRE
∅100 LOW VENT WITH 90° ELBOW
FLOW VELOCITY 1.26 m/s MOSQUITO PROOF MESH NAME OF CLIENT
TURF ALL FINAL GRADES. NO DEEP ROOTED
FLOW RATE 40 L/MIN = 0.67 L/SEC PLANTS ON SYSTEM OR OVERFILL AREAS 100mm PVC PIPE VIKI DIOSZOGI
TYPICAL WARNING SIGN
150
PUMP DUTY 10m HEAD @ 40 L/MIN - COMPLYING WITH AS 1341.9 AT DESIGNER
BOUNDARIES OF LAA
100
OFFSET
ADAPTOR
END VIEW - CLEAR VISIBLE TO PROPERTY C. TAYLOR
USERS
GEOTEXTILE GEOTEXTILE ELBOW LEVEL
- WORDING SUCH AS "RECYCLED DRAWN
FIBER WRAP FIBER WRAP WITH TOP OF
RANDOMLY LEVEL OFFSET WATER - AVOID CONTACT - M. MAHONY
100mm ADAPTOR DO NOT DRINK"
ORIENTATED
SLOPE LEVEL
FIBER MAT RANDOMLY
ORIENTATED
DRAWING DETAILS
AES PIPE TOP VIEW FIBER MAT
OFFSET ADAPTOR 75mm x 50mm HARDWOOD DETAIL
DO NOT INSERT PVC AES PIPE POST OR 100mm TREATED
PIPE MORE THAN 100mm
APPROVED SAND
ORIGINAL SOIL INTO OFFSET ADAPTOR SIDE VIEW OFFSET
LOG JOB NUMBER
ADAPTOR
TE249167
LOW VENT RAISED CONNECTION TYPICAL WARNING SIGN SCALE REVISION DWG #
N/a A SL3
Page 14
Appendix B AES Design Calculator Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568 Taylor Environmental (Australia) Pty Ltd Page 14 of 19
Page 15
Appendix C Treatment Plant Approval Site and Soil Evaluation 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568 Taylor Environmental (Australia) Pty Ltd Page 16 of 19
Page 16
TREATMENT PLANT APPROVAL 06/2024
Plumbing and Drainage Regulation 2019, part 4.
Approval
1. The Advanced Enviro-Septic 30 (AES-30) (“the system”) described in the Specifications and
Drawings in the attached Schedule and manufactured by Presby Environmental Inc. Whitefield,
New Hampshire (“the manufacturer”) and supplied by Chankar Environmental Pty Ltd (ACN
148 175 455) (“the supplier”) has been assessed in accordance with:
(a) sections 34 and 35 of the Plumbing and Drainage Regulation 2019 and
(b) the Queensland Plumbing and Wastewater Code published on 26 October 2017.
2. A transitional Treatment plant Approval (TPA) is granted for an advanced secondary quality
wastewater treatment system , subject to compliance by the manufacturer/supplier with the
requirements of the Plumbing and Drainage Act 2018 and the conditions of approval detailed
below.
3. As no changes have been made to the system, this approval replaces the previous approval,
TPA 15/2019 Amendment 2 issued on 20 January 2023.
4. This approval, the conditions of approval, and the Schedule comprise the entire TPA document.
5. Any modification by the manufacturer/supplier to the design, drawings or specifications
scheduled to this approval must be approved by the Chief Executive.
Conditions of approval
6. The manufacture, installation, operation, service, and maintenance of the system must be in
conformity with the conditions of this TPA.
7. The advanced secondary quality wastewater treatment system, which is an example of the
approved systems, may only be used on premises that generate per day:
a) a maximum hydraulic loading of 90 L per 3 m length of AES piping system.
b) a maximum organic loading of 240 mg/L BOD5.
c) a maximum total suspended solids of 300 mg/L.
8. The system must continue to meet the requirements of an advanced secondary quality
wastewater treatment system, producing the following effluent quality —
a) 90% of the samples taken must have a BOD5 less than or equal to 10 g/m³ with no sample
greater than 20 g/m³.
b) 90% of the samples taken must have total suspended solids less than or equal to 10 g/m³
with no sample greater than 20 g/m³.
9. Each system must be serviced in accordance with the details supplied in the owner’s operation
and maintenance manual.
10. The system design is based upon secondary quality effluent design loading rate as defined in
AS/NZ1547 using the Advanced Enviro-Septic (AES) Design Calculator prepared by a qualified
designer. System designs must be verified and signed by the supplier before being submitted to
the Local Government.
1
Page 17
TREATMENT PLANT APPROVAL 06/2024
Plumbing and Drainage Regulation 2019, part 4.
11. A septic tank conforming to AS/NZ 1546.1 and sized in accordance with AS/NZ 1547 for
treatment of all daily flows of domestic wastewater from the premises is a component of the
system. Effluent from the septic tank is to be diverted to the AES piping system prior to the system
sand and basal area. The septic tank that feeds into the system must be regularly monitored and
maintained (including de-sludging) in accordance with AS/NZ 1547 to ensure optimum operation
of the system.
12. Where gravity cannot be achieved to transfer effluent from septic tank to the AES treatment pipes:
(a) A pump well is to be used and sized as per AS/NZ1547:2012 and maintain at least 24-
hour emergency storage above the high-water level alarm sensor.
(b) The pump is to be a submersible type with high level alarm as specified in both
AS1546.3:2017 and AS/NZ 1547:2012. The pump shall be a Davey D25VA or equivalent,
with a design flow of 40 L/min at a minimum 6 m head. Should site conditions require a
higher head, then the appropriate pump model to achieve this shall be selected.
(c) In each situation, the design of the AES system must confirm with the manufacturer’s
design recommendations set out in the AES Calculator & Design and Installation Manual.
13. When granting a compliance permit, the local government must satisfy itself that the designer’s
choice of the system configuration is optimal for the proposed use and site conditions and that
the effluent can be retained within the land application area.
14. Each application for a compliance permit to install a system must also be accompanied by a copy
of a completed AES Design Calculator Report endorsed by the supplier, showing the
footprint/basal area of the proposed system and number of pipe modules for the site.
15. An inspection/sampling point must be installed permanently in the sand immediately below the
half-way point of the AES piping system. Where a system is installed in a sloping basal area an
additional inspection/sampling point must be installed at the lowest point of the system extension.
16. Routine maintenance of the system at set intervals, other than septic tank sludge levels, is not
stipulated by the manufacturer/supplier. However, routine monitoring may be required by the
Local Government. In the event of failure of the system’s land application area an AES
authorised person may need to follow the rejuvenation procedures set out in the
manufacturer/supplier’s Design and Installation Manual.
17. Where a system installed at a site, has been found not to operate satisfactorily during its service
life, and as a result requires modification to achieve the required performance requirements, in
particular, water quality limits, the installed system is to be modified accordingly. Any
modifications including any of the supplier’s rejuvenation procedure outcomes must be recorded
on the service report.
18. Permitted use of the effluent is for sub-surface absorption only.
19. Each system must be supplied with —
(a) a copy of this Treatment Plant Approval document;
(b) details of the system;
(c) instructions for authorised persons for its installation;
(d) a copy of the owner’s manual to be given to the owner at the time of installation; and
(e) detailed instructions for authorised service personal for its operation and maintenance.
2
Page 18
TREATMENT PLANT APPROVAL 06/2024
Plumbing and Drainage Regulation 2019, part 4.
20. At each anniversary of the TPA date, the supplier must submit to the Chief Executive a list of all
systems installed in Queensland during the previous 12 months. Where the Chief Executive is
notified of any system failures the Chief Executive may randomly select several installed systems
for audit. The Chief Executive will notify the supplier’s nominated NATA accredited laboratory
which systems are to be audited for BOD5 and TSS. The sampling and testing of the selected
systems, if required, is to be done at the supplier’s expense. The following results must be
reported to the Chief Executive:
a) Address of premises;
b) Date inspected and sampled;
c) Sample identification number;
d) BOD5 for influent and effluent; and
e) TSS for influent and effluent.
21. The Chief Executive may, by written notice, cancel this approval if the manufacturer/supplier fails
—
a) to comply with one or more of the conditions of approval; or
b) within 30 days, to remedy a breach, for which a written notice been given by the Chief
Executive.
22. This approval may only be assigned with the prior written consent of the Chief Executive.
23. Where there is any inconsistency between the content of this approval and the Plumbing and
Drainage Act 2018 (including any associated regulation and/or codes), the provisions of the
Plumbing and Drainage Act 2018 will apply and must be adhered to.
24. This approval expires on 1 January 2025 unless cancelled earlier in accordance with paragraph
21 above.
Lindsay Walker
Director Level 15,
Plumbing, Drainage and Special Projects 53 Albert Street Brisbane
Date approved: 26 April 2024. GPO Box 2457, Brisbane Qld 4001
Telephone +61 7 3008 2557
Website www.business.qld.gov.au
3