                             SOIL CHARACTERISTICS

                                  0 - 300 LOW PLASTICITY SANDY CLAY LOAM
   SOIL PROFILE AT BH1
                                  300 - 1200 MEDIUM PLASTICITY SANDY CLAY                                                                                                                                                                                                                                                                                      REVISIONS
                                                                                                                  3m HIGH VENT. ATTACH TO
                                                                                                                  BOLLARD FOR SUPPORT                                                                                                                                                                                                            #    DATE       SUBJECT          AUTHORISED
                                           CLAY LOAM AT 900 DEEP
      RECEIVING SOIL                                                                                                                                                                                                                                                                                                                             A    06/11/2024 REVISION A       C. TAYLOR
                                              (AES BASAL AREA)
                                                                                                                           OFFSET ADAPTER                                 COUPLING                                            STRAIGHT RAISED CONNECTOR                                                               ∅100 LOW VENT
       STRUCTURE                            STRONGLY STRUCTURED                         ∅100 uPVC
                                                                                 VELOCITY REDUCER
     SOIL CATEGORY                                      5                            [1m LONG MIN]




                                                                                                                                                                                                                                                                                                                             900
   PERMEABILITY (KSAT)                          0.12 - 0.5 m/DAY

   DESIGN LOADING RATE                              12 mm/DAY               ∅32OD ∅26ID PN12.5




                                                                                                                                                                                                                                                                                                                                    1940
                                DESIGN VOLUME
                                                                            LILAC COATED PIPE                                                                                                                                                                                                 INSPECTION POINT




                                                                                                                                                                                                                                                                                                                             1040
                                                                                                                                                 3m LONG ∅300 AES PIPE
     WATER SUPPLY                         RAIN WATER & BORE WATER                                                                                1 ROW OF 4 PIPES                                                            INSPECTION POINT
                                               150 L/P/DAY                                                                                                                                                                                                                                                                                           TAYLOR ENVIRONMENTAL
   VOLUME ALLOWANCE              (CONSERVATIVE ALLOWANCE WITH COMPOSTING
                                                  TOILET)                                                  300                                                     6000                                            300                                                    6000                                         300
  NUMBER OF BEDROOMS                               LOFT BEDROOM
                                                                                                                                                                                                                 12900
    DESIGN POPULATION                               2 PERSONS

  TOTAL DESIGN VOLUME                               300 L/DAY

                                 TREATMENT                                                                                                                                            AES BED PLAN VIEW                                                                                   AES BED CONSTRUCTION:
                                                                                                                                                                                                                                                                                           - TO BE INSTALLED AS PER MANUFACTURERS
  SEPTIC TANK CAPACITY                               3000L MIN                                                                                                                                                                                                                                SPECIFICATIONS AND BY A SUPPLIER APPROVED PERSON
                                                                                                                                                                                                                                                                                           - EXCAVATE WITH LASER LEVEL
                                        ADVANCED ENVIRO SEPTIC (AES)                                                                                                                                                                                                                       - RIP LEVEL OF BASE ≈200 to 300mm
    TYPE OF FACILITY
                                              MODEL: 30L/MIN                                                                                                                                                                                                                               - RE-EXCAVATE BACK TO CORRECT LEVEL USING A LASER
                                                                                                                                                                                                                                                                                              LEVEL
    TREATMENT LEVEL                          ADVANCED SECONDARY                                                                                                                                                                                                                            - GYPSUM BASE AT 1kg/m2
                                                  06 - 2024                                                                                                                                                                                                                                - PLACE AES APPROVED SAND TO SPECIFIED DEPTH
           TPA                                                                                                                                                                                                                                                                                UNDER PIPES
                                             (LAPSES 1 JAN 2025)




                                                                                                                                                                                                      MIN 3m
                                                                                                                                                              ∅100 HIGH VENT                                                                                                               - PLACE AES PIPES AND CONNECTORS, ENSURING THEY
                               DISPOSAL AREA                                                                                                                                                                                                                                                  ARE LEVEL ACROSS THE ENTIRE LENGTH
                                                                                                                                                                                                                                                                                           - PLACE AES APPROVED SAND TO SPECIFIED DEPTH
MINIMUM AES AREA REQUIRED                       A = Q/DLR = 25m²                                                                                                                                                                                                                              OVER PIPES
                                                                                                                                                                                                                INSPECTION POINT                                                           - REPLACE EXCAVATED TOP SOIL TO A MINIMUM DEPTH             QBCC LICENCE NUMBER 150 556 72
  AES FOOTPRINT AS PER                                                                                                                                                                                                              BACK FILL MOUND OVER AES                                  OF 150mm                                                    ABN NUMBER 95268308955
                                             12.9m x 1.94m = 22 m²                                                                                                                                                                                                                         - ESTABLISH GRASS TO PROMOTE EVAPOTRANSPIRATION
 AES DESIGN CALCULATOR
                                                                                                                                 STORMWATER                                                                                                                                                - NO TREES WITHIN 2m OF BED
NUMBER OF AES PIPE ROWS                               1 ROWS                                                                        DIVERSION                                                                                        APPROVED SAND                                                                                                         Phone: +61 400 301 364
                                                                                                                                                               ∅100 LOW VENT                                                                                                                                                                           Email: [email protected]




                                                                                                                                                                                                                150 MIN
NUMBER OF AES PIPES/ROW                            4 PIPES/ROW                                                                                                                                                                             GRASS                                                                                                        Web: www.taylorenviro.com.au
    BUFFER CAPACITY                                   869 L                                                                                                                                                                                             INSPECTION POINT
                              BILL OF QUANTITIES




                                                                                                                                                                                       150




                                                                                                                                                                                                                                                                150 MIN
        AES PIPES                                       4
                                                                                                                                                                                     300               300
                                                                                                                                                                                                                                                                                                                                                  WASTE WATER TREATMENT &




                                                                                                                                                                          750
        COUPLINGS                                       2
                                                                                                                                                                                                                                                                               22% S                                                              EFFLUENT DISPOSAL SYSTEM




                                                                                                                                                                                             300
    OFFSET ADAPTOR                                      4
                                                                                                                                                                                                                                                                                       LOPE




                                                                                                                                                                                                                                                                150
  OXYGEN DEMAND VENT                                     1

  INSPECTION POINT BASE                                 2                                                                                                                                    900                                    1040                                                                                                         AUTHORISED FOR ISSUE            DATE
   CLEAN COURSE SAND                                   13 m³
                                                                                                                                                                                                               1940                                                                                                                                                             06/11/2024
                                 PUMP DUTY

  HEAD LOSS: PUMPWELL                                  2m                                                                                        RIP & SCARIFY 300mm                                                                                                                                                                             STREET ADDRESS
                                                                                                                                                 APPLY GYPSUM 1kg/m²                                                                                                                                                                             328 UPPER PINBARREN CREEK RD, PINBARREN
  HEAD LOSS: ELEVATION                                 4m
                                                                                                                                                                                                                                                                                                                                                 LOT & PLAN
FRICTION LOSS: RISING MAIN                             4m
                                                                                                                                                                                AES BED SECTION VIEW                                                                                                                                             LOT 3 RP851976
       TOTAL LOSS                                      10 m
                                                                                                                                                                                                                                                                                                                                                 COUNCIL
       RISING MAIN                            ∅32OD ∅26ID PN12.5
                                                                                                                                                                                                                                                                                                                                                 NOOSA SHIRE
                                                                                                                                       ∅100 LOW VENT WITH                                                                             90° ELBOW
     FLOW VELOCITY                                   1.26 m/s                                                                         MOSQUITO PROOF MESH                                                                                                                                                                                        NAME OF CLIENT
                                                                                            TURF ALL FINAL GRADES. NO DEEP ROOTED
       FLOW RATE                             40 L/MIN = 0.67 L/SEC                           PLANTS ON SYSTEM OR OVERFILL AREAS                                                                                                      100mm PVC PIPE                                                                                              VIKI DIOSZOGI
                                                                                                                                                                                                                                                                                                             TYPICAL WARNING SIGN
                                                                                                                                                        150




       PUMP DUTY                             10m HEAD @ 40 L/MIN                                                                                                                                                                                                                                              - COMPLYING WITH AS 1341.9 AT      DESIGNER
                                                                                                                                                                                                                                                                                                                BOUNDARIES OF LAA
                                                                                                                           100
                                                                                                                                                                                                                           OFFSET
                                                                                                                                                                                                                          ADAPTOR
                                                                                                                                                                                                                                        END VIEW                                                              - CLEAR VISIBLE TO PROPERTY        C. TAYLOR
                                                                                                                                                                                                                                                                                                                USERS
                                                                                             GEOTEXTILE                                                                                                                                    GEOTEXTILE            ELBOW LEVEL
                                                                                                                                                                                                                                                                                                              - WORDING SUCH AS "RECYCLED        DRAWN
                                                                                             FIBER WRAP                                                                                                                                    FIBER WRAP            WITH TOP OF
                                                                                         RANDOMLY                                 LEVEL                                                                                                                          OFFSET                                         WATER - AVOID CONTACT -          M. MAHONY
                                                                                                                                                                                                                                              100mm              ADAPTOR                                        DO NOT DRINK"
                                                                                        ORIENTATED
                                                                                                                                                SLOPE                                                                                                   LEVEL
                                                                                         FIBER MAT                                                                                                               RANDOMLY
                                                                                                                                                                                                                ORIENTATED
                                                                                                                                                                                                                                                                                                                                                 DRAWING DETAILS
                                                                                          AES PIPE                                                                                         TOP VIEW              FIBER MAT
                                                                                                                                              OFFSET ADAPTOR                                                                                                                                                     75mm x 50mm HARDWOOD            DETAIL
                                                                                                                                                                                      DO NOT INSERT PVC            AES PIPE                                                                                      POST OR 100mm TREATED
                                                                                                                                                                                      PIPE MORE THAN 100mm
                                                                                                                APPROVED SAND
                                                                                                                                                   ORIGINAL SOIL                      INTO OFFSET ADAPTOR                              SIDE VIEW        OFFSET
                                                                                                                                                                                                                                                                                                                 LOG                             JOB NUMBER
                                                                                                                                                                                                                                                        ADAPTOR
                                                                                                                                                                                                                                                                                                                                                 TE249167
                                                                                                                  LOW VENT                                                                         RAISED CONNECTION                                                                             TYPICAL WARNING SIGN                                SCALE         REVISION         DWG #
                                                                                                                                                                                                                                                                                                                                                      N/a             A              SL3
Log in to download the original file

SSE - TE249167 - 328 Upper Pinbarren Creek Road, Pinbarren Qld 4568.pdf · 3.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.