Appendix 6 - Light spill report
RESIDENTIAL BOUNDARY B (NOTE 2) 3m ACOUSTIC BARRIER RESIDENTIAL BOUNDARY A (NOTE 2) 1.8m SCREENING FENCE
S 5000L RAIN
SITE BOUNDARY WATER TANKS
STORMWATER BIORETENTION NOTE 4
3000
BASIN AS PER ENGINEERS
Obtrusive Light - Compliance Report S S S S S S S S
S REPORT 15M2
1000
AS 4282-2019, Post-Curfew, Commercial 5430 28184
LANDSCAPING TO
SEATING AREA AS
OVERALL BUILDING
Filename: 250-12 BP Noosaville_External Lighting 27684
INTERNAL CLEAR
PER LANDSCAPE
DETAILS
REFUSE S ENTRY / EXIT
18/06/2019 DELIVERY & EXISTING
GARBAGE CROSSOVER
TRUCK PARK
OVERALL BUILDING
INTERNAL CLEAR
Illuminance 3m S
SERVICE STATION FEATURE TREE AS
8970
9470
PER LANDSCAPE
250m 2 (GLA)
Maximum Allowable Value: 5 Lux (AS4282 2019: Category A4) ACOUSTIC BOL
INTERNAL LAYOUT AS
DETAILS
BARRIER BOL
PER TENANTS
DOCUMENTATION
S
Calculations Tested (2): LINE OF
ROOF OVER
Test Max.
LINE OF PEDESTRIAN ACCESS
Calculation Label Results Illum. ROOF OVER S
3000
Residential Boundary A_Ill PASS 3.1 GAS BOTTLES
PROPOSED
GROW-WALL
3000
PROPOSED
GROW-WALL
9600
SHOPFRONT
PROPOSED
GROW-WALL
HALF HEIGHT
GLAZING SHARED ZONE
PEDESTRIAN ENTRY
ARBOUR AS PER
LANDSCAPE DETAILS
Residential Boundary B_Ill PASS 1.2
S 1.
FLUSH SET FEATURE PAVEMENT TO 3000
LANDSCAPE DETAILS ACCESSIBLE
LANDSCAPING
Luminous Intensity (Cd) At Vertical Planes LINE OF LINK
S OVER
ROOF
LINE OF LINK
ROOF OVER
2.
AIR AND WATER
Maximum Allowable Value: 2500 Cd
4000
COMMERCIAL 3000
1000
1300
Calculations Tested (2): BOUNDARY EXTENT OF CATCHMENT AREA S
Test (NOTE 1)
BOL. 3.
2000
LINE OF FUEL CANOPY OVER
SUMP SUMP SUMP SUMP SUMP SUMP
Calculation Label Results
3200
2700
BIN BOL. BOL. BOL. BOL. 5400
NEW FOOTPATH
S
BIORETENTION BASIN
CL
Residential Boundary A_Cd_Seg1 PASS
COL.
COL.
COL.
COL.
COL.
STORMWATER
4.
Residential Boundary B_Cd_Seg1 PASS
20M 2
LANDSCAPING
CL
DISPENSER
DISPENSER
DISPENSER
DISPENSER
DISPENSER
SUMP SUMP
CL
S
1.8m
3200
COL.
COL.
COL.
COL.
COL.
5.
SCREENING
900
BIN BIN BIN BIN
NOTES FENCE 1300 3200
BOL. EXTENT OF CATCHMENT AREA S BOL. BOL. BOL. BOL.
LANDSCAPING
1. POST -CURFEW OBTRUSIVE LIGHT ASSESSMENT TO ADJACENT COMMERCIAL PROPERTY LINE OF FUEL CANOPY OVER 6.
TANK FILL POINT
EXCLUDED (NON-RESIDENTIAL). PRE-CURFEW CALCULATION AT COMMERCIAL TO S
11600
COMMERCIAL BOUNDARY IN REFERENCE TO AS4282 CATEGORY A4 PROVIDES THE 7.
FOLLOWING -
S
ILLUMINANCE: 24.8 LUX (MAX) (25 LUX ALLOWABLE) PASS
INTENSITY: 847 Cd (MAX) (25,000 Cd ALLOWABLE) PASS NEW 60 000 LITRE
FUEL STORAGE TANKS PYLON
S VENT
SITE BOUNDARY
2. RESIDENTIAL CALCULATION POINTS WERE TAKEN AT THE BOUNDARY & NOT AT THE EXTERNAL PIPES
WALL OF THE DWELLINGS. THE LEVELS AT THE BOUNDARY ARE HIGHER THAN THAT AT THE LANDSCAPING EXIT ONLY LANDSCAPING
EXISTING
3000
3000
DWELLINGS I.E. COMPLIANCE ALSO ACHIEVED AT DWELLING WALLS. S POWER POLE
SITE BOUNDARY
3. CALCULATIONS DO NOT ALLOW FOR LANDSCAPING VEGETATION NEAR BOUNDARIES. TREES
S
2000
NEW FOOTPATH NEW FOOTPATH
AND OTHER VEGETATION MAY REDUCE OBTRUSIVE LIGHTING LEVELS TO ADJACENT NEW FOOTPATH ENTRY ONLY
PROPERTIES. EXISTING EXISTING
POWER POLE POWER POLE 600
S
4. SECURITY LIGHTING WHERE REQUIRED AT REAR OF BUILDING TO BE DIRECTED DOWN AND BE MARY STREET
MOUNTED BELOW HEIGHT OF 3m ACOUSTIC FENCE.
5. THRESHOLD INCREMENT CALCULATION RESULTS FOR BOTH ADJACENT ROADS WERE Calculation Summary
COMPLIANT TO AS4282:2019 BEING LESS THAN 20% AT DEFAULT ADAPTATION LEVEL OF 5 STEVEN ACZEL
RPEQ 11952 Label CalcType Units Avg Max Min
Cd/m2 FOR CATEGORY A4 (PASS).
Residential Boundary A_Cd Obtrusive Light - Cd N.A. 86.16 1052 0
Luminaire Schedule Residential Boundary A_Ill Obtrusive Light - Ill Lux 0.24 3.1 0.0
Symbol Qty Label LLF Description Residential Boundary B_Cd Obtrusive Light - Cd N.A. 211.76 364 0
1 GAMMA ILLUMINATION 1353-4K-28W 1.0 MAXIMUS 1353-4K-28W Residential Boundary B_Ill Obtrusive Light - Ill Lux 0.2 1.2 0.0
20 SLOANLED-PDL3MODUSHO-C 120W 1.0 SLOANLED PDL3MH Commercial Boundary_Cd Obtrusive Light - Cd N.A. 188.27 847 0
1 LSI SLM-LED-12L-SIL-FT-50-70CRI 95W 1.0 SLM-LED-12L-SIL-FT-50-70CRI Commercial Boundary_Ill Obtrusive Light - Ill Lux 1.63 24.8 0.0
rev date drawn reason for issue consulting engineer project
PART OF THIS DRAWING
BE TAKEN FROM THE
S I T E
ALL DIMENSIONS ARE TO
ARCHITECTS DRAWINGS &
DO NOT SCALE ANY
1 18.06.19 JL APPROVAL Cushway Blackford & Associates Pty Ltd
ABN 23 010 522 988
BP NOOSAVILLE
OBTRUSIVE LIGHTING REPORT
ELECTRICAL SERVICES
P 07 3896 1100 scale designed drawn
E [email protected] drawing title 1:250@A3 SA JL
5 Trafalgar Street, Woolloongabba QLD 4102 CALCULATION RESULTS project number drawing number revision
O N
PO Box 1517, Coorparoo DC QLD 4151
251-12 E01 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.