Original source · versioned page text
Swmp
Treatment Measures
Runoff from the development will be treated through two bioretention basins or flow split to a
number of devices. The potential locality of the treatment devices servicing the
development is shown in Figure 3-1.
3.3.1. Bioretention System
Bioretention systems use ponding above a treatment surface to maximise the volume of
runoff flowing through the filtration media. They typically convey flows above the design
event through overflow pits or a weir. The treatment system operates by firstly filtering surface
flows through surface vegetation and then percolating runoff through prescribed filtration
media. This media provides treatment through fine filtration, extended detention and
biological uptake of nutrients.
As these systems take approximately 12-24hrs to drain, the maximum depth of pondage
allowed to occur over the filter area has been limited to 300mm, with a minimum filter media
depth of 500mm. Table 3-5 summarises the proposed design parameters for the main
bioretention system for this development. As noted above this may be split into several
devices on detailed design. It is to be noted that the Orthophosphate content of the filter
media has been reduced to 30mg/kg in line with recent advice from Healthy Waterways.
(http://healthywaterways.org/initiatives/waterbydesign/stormwater).
Table 3-5: Bioretention Design Parameters
Parameter Bioretention Basin
A
Extended Detention Depth (m) 0.30
Storage Surface Area (m2) 120
Filter Media Area (m2) 120
Unlined Filter Media Perimeter (m) 0.01
Saturated Hydraulic Conductivity (mm/hr) 200
Filter Depth (m) 0.5
TN Content of Filter Media (mg/kg) 400
Orthophosphate Content of Filter Media (mg/kg) 30
Exfiltration Rate (mm/hr) 0.0
21-0166SMP01-V1 | Stormwater Management Plan | 25 Pavilion Street, Pomona | 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.